Matches in SemOpenAlex for { <https://semopenalex.org/work/W1573055433> ?p ?o ?g. }
Showing items 1 to 79 of
79
with 100 items per page.
- W1573055433 endingPage "7" @default.
- W1573055433 startingPage "5" @default.
- W1573055433 abstract "Watch a video presentation of this article Answer questions and earn CME Since the advent of laparoscopic cholecystectomy in 1985 by the German surgeon Erich Mühe, surgeons worldwide have sought to enhance technique and instrumentation in order to improve postoperative recovery and patient satisfaction while maintaining safety.1 As a result, patients have experienced shorter hospitalizations, less postoperative pain, and improved cosmesis. Laparoscopic cholecystectomy is now the gold standard for treating benign gallbladder pathology. In recent years, there has been a trend to reduce the number of incisions from the traditional four-port technique. Thus, single-port or single-incision laparoscopic cholecystectomy (SILC) has been introduced to improve patient satisfaction in the hopes of reducing incisional pain and improving cosmetic outcomes. Herein we describe the technical aspects of this procedure and compare its outcomes with the traditional laparoscopic technique. As the name suggests, single-port or SILC utilizes one skin incision for the insertion of laparoscopic instruments and camera into the peritoneal cavity. Although initial attempts involved the utilization of standard laparoscopic instruments and ports, mostly through separate fascial stab incisions under the same skin incision, it was readily obvious that the lack of triangulation and adequate visualization make the procedure technically challenging and increase the risks of complications.2 Thus, various iterations of specialized ports and curved or articulating instruments have been developed by the surgical device industry (Fig. 1). With all these, technical challenges and safety concerns still persist; consequently, there has been a significantly downward trend in the utilization of SILC over the last few years. Surgical societies made attempts to standardize the technique.3 We strongly recommend that surgeons attend a training course if they are unfamiliar with this approach. In addition, it may be beneficial to have a proctor for the first several cases. Patient selection is also critical to success. While still new in utilizing SILC, surgeons should avoid patients with acute cholecystitis, morbid obesity, and previous abdominal operations. From a technical point of view, using long instruments can avoid collisions at the entry site to facilitate the procedure. Using angled laparoscopes also improves maneuverability and visualization while improving the range of motion for the working instruments. We prefer long 5-mm 30-degree angled scopes or deflectable tip scopes. Although we have moved away from using articulated instruments, they can be required for challenging cases. Table 1 lists some of the currently available ports and their features. Laparoscopic incision-site ports: (A) SILS (Covidien); (B) Quadport+ (Advanced Surgical/Olympus); (C) GelPOINT Mini (Applied Medical). In order to overcome some of the challenges, new platforms for single-site surgery emerged and some of them received US Food and Drug Administration (FDA) approval. SPIDER Surgical System (TransEnterix, Durham, NC) provides abdominal access through a single cannula attached to the operating table, which accommodates a rigid instrument, two flexible instruments, and a laparoscopic camera. Upon intra-abdominal deployment, the flexible instruments provide the working space and triangulation necessary to perform the cholecystectomy (Fig. 2). SPIDER Surgical System. However, the system most widely utilized nowadays for SILC is likely the robotic da Vinci single-site platform (Intuitive Surgical, Sunnyvale, CA). A pliable 4-lumen single-site port inserted through a 2.5-cm fascial incision provides access to a standard laparoscopic instrument, a three-dimensional laparoscope, and two curved semirigid-robotic instruments (Fig. 3). The setup enables surgeons to perform SILC with improved dexterity, comfort, visualization, and ease of manipulation when compared with other single-site modalities.4 No other robotic platforms are currently FDA-approved for clinical use. Da Vinci single-site platform. (A) single-site setup; (B) single-site setup attached to the robotic arms. Although the same principles of traditional laparoscopic cholecystectomy apply to SILC, these less invasive techniques introduce unique challenges to the surgeon. Port placement during traditional laparoscopy is key to avoid contact between instruments and the ability to correctly expose key structures. In SILC, the instrument proximity can obstruct the surgeon's view and make manipulation of relevant anatomy difficult. Consequently, some surgeons experienced difficulty in achieving the critical view of safety, which resulted in increased common bile duct or vascular injuries (Fig. 4). Thus, robotic single-platform cholecystectomy seems to be an exciting alternative to traditional laparoscopy, providing convenient instrumentation and enhanced surgical views. Critical view of safety: The proximal part of the gallbladder is separated from the liver bed; and only two 2 structures enter the gallbladder in the triangle of Calot, which is completely cleared of fat and fibrous tissue. The common bile duct does not need to be exposed. A few randomized controlled trials have been published comparing SILC with traditional laparoscopic cholecystectomy. Most of them found that SILC is associated with slightly increased postoperative complications, wound-related problems, and port-site hernia incidence when compared with multiport cholecystectomy, as well as significantly higher operative time and improved cosmesis.5 The largest randomized study to date (100 patients in each arm) concluded that SILC is associated with significantly improved cosmesis and increased port-site hernia rates at 1 year.6 No randomized studies have been published to date comparing robotic single-site cholecystectomy with standard laparoscopy or SILC. However, the available literature suggests that the learning curve is steeper and the operative time is shorter with the robotic platform compared with SILC.7, 8 Single-incision laparoscopic cholecystectomy is a viable option by adequately trained surgeons in selected patients. Further refinements of technology will likely lead to increased acceptance while maintaining outcomes similar to standard laparoscopic cholecystectomy." @default.
- W1573055433 created "2016-06-24" @default.
- W1573055433 creator A5000490949 @default.
- W1573055433 creator A5029085878 @default.
- W1573055433 creator A5087368559 @default.
- W1573055433 date "2015-01-01" @default.
- W1573055433 modified "2023-09-26" @default.
- W1573055433 title "Single-incision laparoscopic cholecystectomy" @default.
- W1573055433 cites W2011630471 @default.
- W1573055433 cites W2037060451 @default.
- W1573055433 cites W2049080272 @default.
- W1573055433 cites W2053205308 @default.
- W1573055433 cites W2062923199 @default.
- W1573055433 cites W2081056240 @default.
- W1573055433 cites W2091630983 @default.
- W1573055433 cites W2107891445 @default.
- W1573055433 doi "https://doi.org/10.1002/cld.431" @default.
- W1573055433 hasPubMedCentralId "https://www.ncbi.nlm.nih.gov/pmc/articles/6490441" @default.
- W1573055433 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/31312434" @default.
- W1573055433 hasPublicationYear "2015" @default.
- W1573055433 type Work @default.
- W1573055433 sameAs 1573055433 @default.
- W1573055433 citedByCount "1" @default.
- W1573055433 countsByYear W15730554332020 @default.
- W1573055433 crossrefType "journal-article" @default.
- W1573055433 hasAuthorship W1573055433A5000490949 @default.
- W1573055433 hasAuthorship W1573055433A5029085878 @default.
- W1573055433 hasAuthorship W1573055433A5087368559 @default.
- W1573055433 hasBestOaLocation W15730554331 @default.
- W1573055433 hasConcept C119599485 @default.
- W1573055433 hasConcept C126322002 @default.
- W1573055433 hasConcept C127413603 @default.
- W1573055433 hasConcept C141071460 @default.
- W1573055433 hasConcept C2775944032 @default.
- W1573055433 hasConcept C2776641081 @default.
- W1573055433 hasConcept C2780047204 @default.
- W1573055433 hasConcept C2780943399 @default.
- W1573055433 hasConcept C2994102832 @default.
- W1573055433 hasConcept C32802771 @default.
- W1573055433 hasConcept C40993552 @default.
- W1573055433 hasConcept C61434518 @default.
- W1573055433 hasConcept C71924100 @default.
- W1573055433 hasConceptScore W1573055433C119599485 @default.
- W1573055433 hasConceptScore W1573055433C126322002 @default.
- W1573055433 hasConceptScore W1573055433C127413603 @default.
- W1573055433 hasConceptScore W1573055433C141071460 @default.
- W1573055433 hasConceptScore W1573055433C2775944032 @default.
- W1573055433 hasConceptScore W1573055433C2776641081 @default.
- W1573055433 hasConceptScore W1573055433C2780047204 @default.
- W1573055433 hasConceptScore W1573055433C2780943399 @default.
- W1573055433 hasConceptScore W1573055433C2994102832 @default.
- W1573055433 hasConceptScore W1573055433C32802771 @default.
- W1573055433 hasConceptScore W1573055433C40993552 @default.
- W1573055433 hasConceptScore W1573055433C61434518 @default.
- W1573055433 hasConceptScore W1573055433C71924100 @default.
- W1573055433 hasIssue "1" @default.
- W1573055433 hasLocation W15730554331 @default.
- W1573055433 hasLocation W15730554332 @default.
- W1573055433 hasLocation W15730554333 @default.
- W1573055433 hasLocation W15730554334 @default.
- W1573055433 hasOpenAccess W1573055433 @default.
- W1573055433 hasPrimaryLocation W15730554331 @default.
- W1573055433 hasRelatedWork W1996381166 @default.
- W1573055433 hasRelatedWork W2010627504 @default.
- W1573055433 hasRelatedWork W2020801371 @default.
- W1573055433 hasRelatedWork W2161198056 @default.
- W1573055433 hasRelatedWork W2364965746 @default.
- W1573055433 hasRelatedWork W2468942975 @default.
- W1573055433 hasRelatedWork W2730837342 @default.
- W1573055433 hasRelatedWork W3015496936 @default.
- W1573055433 hasRelatedWork W4205162995 @default.
- W1573055433 hasRelatedWork W4309179352 @default.
- W1573055433 hasVolume "5" @default.
- W1573055433 isParatext "false" @default.
- W1573055433 isRetracted "false" @default.
- W1573055433 magId "1573055433" @default.
- W1573055433 workType "article" @default.