Matches in SemOpenAlex for { <https://semopenalex.org/work/W1985049375> ?p ?o ?g. }
Showing items 1 to 74 of
74
with 100 items per page.
- W1985049375 endingPage "986" @default.
- W1985049375 startingPage "985" @default.
- W1985049375 abstract "The partitioning of fluid flows among small and ultrasmall pores of the three-pore model in peritoneal dialysis has been traditionally assessed using 4-hour dwells with 3.86% glucose solutions. Under these conditions, however, back-filtration through small pores has been hard to demonstrate. As nicely shown by Asghar and Davies, however, the use of low-concentration (1.36%) glucose-based solutions allows accurate studies of the partitioning of fluid flows from the peritoneal cavity under conditions of fluid loss. The partitioning of fluid flows among small and ultrasmall pores of the three-pore model in peritoneal dialysis has been traditionally assessed using 4-hour dwells with 3.86% glucose solutions. Under these conditions, however, back-filtration through small pores has been hard to demonstrate. As nicely shown by Asghar and Davies, however, the use of low-concentration (1.36%) glucose-based solutions allows accurate studies of the partitioning of fluid flows from the peritoneal cavity under conditions of fluid loss. As they report in this issue of Kidney International, Asghar and Davies1.Asghar R.B. Davies S.J. Pathways of fluid transport and reabsorption across the peritoneal membrane.Kidney Int. 2008; 73: 1048-1053Abstract Full Text Full Text PDF PubMed Scopus (30) Google Scholar have studied the mechanisms of fluid reabsorption across the peritoneal membrane under conditions of a so-called ‘standardized peritoneal permeability analysis’ in patients on peritoneal dialysis. Paired glucose 3.86% and 1.36% dwell studies were performed using 125I-albumin as an intraperitoneal volume marker. Changes in intraperitoneal sodium concentration and in volume were assessed to determine the transperitoneal clearance of sodium, which, at least during the first hour of the dwell, can be used as an indicator of the ultrafiltration (UF) occurring across the small pores of the three-pore model. This approach, though in an ingeniously simple form, was first described by La Milia et al.2.La Milia V. Di Filippo S. Crepaldi M. et al.Mini-peritoneal equilibration test: a simple and fast method to assess free water and small solute transport across the peritoneal membrane.Kidney Int. 2005; 68: 840-846Abstract Full Text Full Text PDF PubMed Scopus (86) Google Scholar and is here referred to as the La Milia technique. For dwells longer than 1 hour, a correction for the diffusion of Na+ through the small pores is required to correctly assess small-pore UF from the transperitoneal clearance of Na+.3.Smit W. Struijk D.G. Ho-Dac-Pannekeet M.M. Krediet R.T. Quantification of free water transport in peritoneal dialysis.Kidney Int. 2004; 66: 849-854Abstract Full Text Full Text PDF PubMed Scopus (78) Google Scholar The major difference between the analysis of Asghar and Davies1.Asghar R.B. Davies S.J. Pathways of fluid transport and reabsorption across the peritoneal membrane.Kidney Int. 2008; 73: 1048-1053Abstract Full Text Full Text PDF PubMed Scopus (30) Google Scholar and previous analyses of this kind3.Smit W. Struijk D.G. Ho-Dac-Pannekeet M.M. Krediet R.T. Quantification of free water transport in peritoneal dialysis.Kidney Int. 2004; 66: 849-854Abstract Full Text Full Text PDF PubMed Scopus (78) Google Scholar, 4.Parikova A. Smit W. Struijk D.G. et al.The contribution of free water transport and small pore transport to the total fluid removal in peritoneal dialysis.Kidney Int. 2005; 68: 1849-1856Abstract Full Text Full Text PDF PubMed Scopus (40) Google Scholar, 5.Parikova A. Smit W. Struijk D.G. Krediet R.T. Analysis of fluid transport pathways and their determinants in peritoneal dialysis patients with ultrafiltration failure.Kidney Int. 2006; 70: 1988-1994Abstract Full Text Full Text PDF PubMed Scopus (64) Google Scholaris that the present study includes a 1.36% glucose exchange, permitting the analysis of fluid reabsorption occurring when the osmotic gradient has more or less dissipated, and when net fluid reabsorption from the peritoneal cavity to plasma has started. In previous standardized peritoneal permeability analyses, 3.86% glucose exchanges have been used, and the separation of fluid flows among the various fluid conductive pathways (mainly small pores and ultrasmall pores) was carried out in relatively short dwells (4 hours), in which net reabsorption had barely started at the end of the dwell. This is problematic, because it is quite difficult to partition small-pore UF from ultrasmall-pore UF, without error, when total net UF is very small. Therefore, not surprisingly, previous analyses using 3.86% glucose standardized peritoneal permeability dwells have failed to show peritoneal fluid loss occurring via small-pore back-filtration.3.Smit W. Struijk D.G. Ho-Dac-Pannekeet M.M. Krediet R.T. Quantification of free water transport in peritoneal dialysis.Kidney Int. 2004; 66: 849-854Abstract Full Text Full Text PDF PubMed Scopus (78) Google Scholar, 4.Parikova A. Smit W. Struijk D.G. et al.The contribution of free water transport and small pore transport to the total fluid removal in peritoneal dialysis.Kidney Int. 2005; 68: 1849-1856Abstract Full Text Full Text PDF PubMed Scopus (40) Google Scholar, 5.Parikova A. Smit W. Struijk D.G. Krediet R.T. Analysis of fluid transport pathways and their determinants in peritoneal dialysis patients with ultrafiltration failure.Kidney Int. 2006; 70: 1988-1994Abstract Full Text Full Text PDF PubMed Scopus (64) Google ScholarIndeed, in order to study the fluid loss from the peritoneal cavity in hypertonic glucose dwells, dwell time has to be increased markedly beyond 4 hours. Alternatively, it is possible to analyze the mechanisms of fluid loss from the peritoneal cavity in relatively short dwells (4 hours) using peritoneal dialysis solutions with low glucose concentration. This is one of the approaches taken in the study by Asghar and Davies.1.Asghar R.B. Davies S.J. Pathways of fluid transport and reabsorption across the peritoneal membrane.Kidney Int. 2008; 73: 1048-1053Abstract Full Text Full Text PDF PubMed Scopus (30) Google Scholar In 1.36% glucose dwells, fluid reabsorption through small pores starts at around 60 minutes, not at 240 minutes as in 3.86% glucose dwells. Another major advantage in the study of Asghar and Davies1.Asghar R.B. Davies S.J. Pathways of fluid transport and reabsorption across the peritoneal membrane.Kidney Int. 2008; 73: 1048-1053Abstract Full Text Full Text PDF PubMed Scopus (30) Google Scholar is the use of radio-iodinated serum albumin instead of dextran 70 (molecular weight 70,000) as an intraperitoneal volume marker. Dextran 70 is a rather polydisperse dextran mixture, which is relatively rapidly disappearing from the peritoneal cavity during the early phase of the dwell, leading to a tendency to overestimate the apparent initial UF. One ambiguity in all studies using an intraperitoneal macromolecular volume marker is that the disappearance of such a marker from the peritoneal cavity is very complex. For more than 20 years it has been debated to what extent peritoneal marker clearance, KE, represents just local clearance of marker into peritoneal tissues, or lymphatic clearance (lymphatic reabsorption). KE is a complex parameter that includes convection of macromolecules and fluid into the peritoneal tissues. Fluid is drained from the tissues by three mechanisms: (1) small-pore reabsorption, that is, back-filtration of fluid, but not of marker, to the blood capillaries; (2) lymphatic reabsorption (a minor portion); and (3) ‘volume recirculation’ of fluid, but not of marker, back into the peritoneal cavity again. Such a volume recirculation, described at some length in another article,6.Rippe B. Fluid loss and macromolecule clearance from the peritoneal cavity under a serial three-pore membrane/fiber matrix model. Implications of ‘volume recirculation’ between peritoneal cavity and tissue.Nephrol Dial Transplant. 2008Google Scholar will make KE exceed the sum of lymphatic and capillary (small-pore) fluid reabsorption, usually by 0.7–1.0 ml/min. However, only the fluid that effectively leaves the peritoneal cavity by capillary and lymphatic reabsorption will affect the net fluid kinetic parameters. Hence, according to the three-pore model, only the lymphatic reabsorption term (∼0.2–0.3 ml/min) should be added to the net UF curve to establish the (total) transcapillary ultrafiltered volume curve. Despite the use of indicator dilution-assessed volume as a function of dwell time and its complication by the KE term, Asghar and Davies1.Asghar R.B. Davies S.J. Pathways of fluid transport and reabsorption across the peritoneal membrane.Kidney Int. 2008; 73: 1048-1053Abstract Full Text Full Text PDF PubMed Scopus (30) Google Scholar have done a very scrupulous evaluation of peritoneal fluid reabsorption and how it is partitioned among the different fluid conductive pathways for 1.36% glucose dwells. Figure 1a shows the computer-simulated partitioning of the partial UF flows through the different pores of the three-pore model for 1.36% glucose, using standard model parameters for an average patient,7.Rippe B. Levin L. Computer simulations of ultrafiltration profiles for an icodextrin-based peritoneal fluid in CAPD.Kidney Int. 2000; 57: 2546-2556Abstract Full Text Full Text PDF PubMed Scopus (94) Google Scholar after a moderate increase of the plasma colloid osmotic pressure from 22 to 27 mm Hg. This was done to match the high reabsorption found in the patient cohort of Asghar and Davies.1.Asghar R.B. Davies S.J. Pathways of fluid transport and reabsorption across the peritoneal membrane.Kidney Int. 2008; 73: 1048-1053Abstract Full Text Full Text PDF PubMed Scopus (30) Google Scholar The modeling of volumes shows that the transcellular (‘water-only’) UF for 1.36% glucose is rather small during 240 minutes, whereas the small-pore back-filtration is considerable. Furthermore, there is a ‘crossover’ of the net ultrafiltered volume curve and the small-pore ultrafiltered curve at about 180 min. Figure 1b demonstrates that this pattern is more or less exactly mimicked by measured data.1.Asghar R.B. Davies S.J. Pathways of fluid transport and reabsorption across the peritoneal membrane.Kidney Int. 2008; 73: 1048-1053Abstract Full Text Full Text PDF PubMed Scopus (30) Google Scholar Indeed, it is striking how well the measured data correspond to the computer simulation, given the fact that the three-pore model was originally created based on volumetric, not on tracer dilution-assessed, ultrafiltered volumes. The article by Asghar and Davies1.Asghar R.B. Davies S.J. Pathways of fluid transport and reabsorption across the peritoneal membrane.Kidney Int. 2008; 73: 1048-1053Abstract Full Text Full Text PDF PubMed Scopus (30) Google Scholar points to the difficulty of using the La Milia technique for partitioning small-pore ultrafiltered volume from aquaporin-mediated (ultrasmall-pore) ultrafiltered volume when dwells are exceeding 2 hours and net reabsorption of fluid has not yet started in hypertonic dwells. Studies aiming to analyze the pathways of reabsorption of fluid from the peritoneal cavity to plasma should use solutions based on a low glucose concentration (1.36%), or, alternatively, they should substantially extend the dwell times (to 6–8 hours) if hypertonic glucose solutions are used. Under all circumstances, the article by Asghar and Davies1.Asghar R.B. Davies S.J. Pathways of fluid transport and reabsorption across the peritoneal membrane.Kidney Int. 2008; 73: 1048-1053Abstract Full Text Full Text PDF PubMed Scopus (30) Google Scholar represents a nice experimental confirmation of the prediction by the three-pore model that small-pore back-filtration accounts for the bulk of net fluid loss from the peritoneal cavity under conditions of fluid reabsorption from peritoneum to plasma." @default.
- W1985049375 created "2016-06-24" @default.
- W1985049375 creator A5000178583 @default.
- W1985049375 creator A5029789084 @default.
- W1985049375 date "2008-05-01" @default.
- W1985049375 modified "2023-10-16" @default.
- W1985049375 title "Fluid loss from the peritoneal cavity by back-filtration through the small pores of the three-pore model" @default.
- W1985049375 cites W1966460610 @default.
- W1985049375 cites W1998549088 @default.
- W1985049375 cites W2018820165 @default.
- W1985049375 cites W2034676213 @default.
- W1985049375 cites W2050730065 @default.
- W1985049375 cites W2073843574 @default.
- W1985049375 doi "https://doi.org/10.1038/ki.2008.71" @default.
- W1985049375 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/18414434" @default.
- W1985049375 hasPublicationYear "2008" @default.
- W1985049375 type Work @default.
- W1985049375 sameAs 1985049375 @default.
- W1985049375 citedByCount "9" @default.
- W1985049375 countsByYear W19850493752012 @default.
- W1985049375 countsByYear W19850493752013 @default.
- W1985049375 countsByYear W19850493752014 @default.
- W1985049375 countsByYear W19850493752015 @default.
- W1985049375 countsByYear W19850493752016 @default.
- W1985049375 countsByYear W19850493752018 @default.
- W1985049375 countsByYear W19850493752019 @default.
- W1985049375 crossrefType "journal-article" @default.
- W1985049375 hasAuthorship W1985049375A5000178583 @default.
- W1985049375 hasAuthorship W1985049375A5029789084 @default.
- W1985049375 hasBestOaLocation W19850493751 @default.
- W1985049375 hasConcept C105702510 @default.
- W1985049375 hasConcept C105795698 @default.
- W1985049375 hasConcept C128489963 @default.
- W1985049375 hasConcept C141071460 @default.
- W1985049375 hasConcept C142724271 @default.
- W1985049375 hasConcept C192562407 @default.
- W1985049375 hasConcept C2778536324 @default.
- W1985049375 hasConcept C2779056158 @default.
- W1985049375 hasConcept C33923547 @default.
- W1985049375 hasConcept C71924100 @default.
- W1985049375 hasConcept C98055416 @default.
- W1985049375 hasConceptScore W1985049375C105702510 @default.
- W1985049375 hasConceptScore W1985049375C105795698 @default.
- W1985049375 hasConceptScore W1985049375C128489963 @default.
- W1985049375 hasConceptScore W1985049375C141071460 @default.
- W1985049375 hasConceptScore W1985049375C142724271 @default.
- W1985049375 hasConceptScore W1985049375C192562407 @default.
- W1985049375 hasConceptScore W1985049375C2778536324 @default.
- W1985049375 hasConceptScore W1985049375C2779056158 @default.
- W1985049375 hasConceptScore W1985049375C33923547 @default.
- W1985049375 hasConceptScore W1985049375C71924100 @default.
- W1985049375 hasConceptScore W1985049375C98055416 @default.
- W1985049375 hasIssue "9" @default.
- W1985049375 hasLocation W19850493751 @default.
- W1985049375 hasLocation W19850493752 @default.
- W1985049375 hasOpenAccess W1985049375 @default.
- W1985049375 hasPrimaryLocation W19850493751 @default.
- W1985049375 hasRelatedWork W2092820307 @default.
- W1985049375 hasRelatedWork W2150993620 @default.
- W1985049375 hasRelatedWork W2163626977 @default.
- W1985049375 hasRelatedWork W2175551422 @default.
- W1985049375 hasRelatedWork W2409559613 @default.
- W1985049375 hasRelatedWork W2412110404 @default.
- W1985049375 hasRelatedWork W2419210104 @default.
- W1985049375 hasRelatedWork W627140730 @default.
- W1985049375 hasRelatedWork W1682051493 @default.
- W1985049375 hasRelatedWork W3012263363 @default.
- W1985049375 hasVolume "73" @default.
- W1985049375 isParatext "false" @default.
- W1985049375 isRetracted "false" @default.
- W1985049375 magId "1985049375" @default.
- W1985049375 workType "article" @default.