- W2002321343 abstract "In an experimental investigation of subcooled flow nucleate boiling of water at atmospheric pressure on stainless steel it was found that the heat transfer coefficient increased with increasing subcooling and also with increasing wall thickness over the range 0.08–0.20 mm. Bubble size, frequency and the distribution of nucleation sites were measured at 1.7 m s−1 inlet velocity, 84 K subcooling, 0.08-mm wall thickness and heat fluxes 70–95% of the critical flux. The observations were consistent with a model for heat transfer primarily by surface quenching at the bubble frequency, supplemented by single-phase convection and a small contribution from microlayer evaporation. Although the total population of nucleation sites increased with increasing wall superheat, the startup of new sites deactivated many of the sites active at lower superheat. Dans une recherche expérimentale de l'ébullition nucléée d'un écoulement sous-refroidi d'eau à la pression atmosphérique sur l'acier inoxydable, il est trouvé que le coefficient de transfert thermique croît avec l'augmentation du sous-refroidissement et aussi avec l'accroissement de l'épaisseur de la paroi dans le domaine 0,08–0,20 mm. La taille de bulle, la fréquence et la distribution des sites de nucléation sont mesurées à une vitesse d'entrée 1,7ms−1,à 84 K de sous-refroidissement, pour une épaisseur de paroi de 0,08 mm et des flux thermiques à 70–95% du flux critique. Les observations s'accordent avec un modèle de transfert thermique principalement dû à une trempe de la surface à la fréquence des bulles et augmenté par une convection monophasique et par une petite contribution de l'évaporation de micro-couche. Bien que la population totale de sites de nucléation augmente avec la surchauffe de la paroi, le démarrage de nouveaux sites désactive beaucoup de sites actifs à de plus faibles surchauffes. Bei experimentellen Untersuchungen des unterkühlten Strömungssiedens von Wasser bei Atmosphärendruck an rostfreiem Stahl wurde festgestellt, daβ der Wärmeübergangskoeffizient mit gröβer werdender Unterkühlung zunimmt und ebenso mit steigender Wandstärke im Bereich von 0,08 bis 0,20 mm. Gemessen wurden Blasengröβe, Frequenz und Verteilung der Siedekeime bei einer Eintrittsgeschwindigkeit von 1,7 m s−1, einer Unterkühlung von 84 K, einer Wandstärke von 0,08 mm und bei Wärmestromdichten, die 70 bis 95% der kritischen Wärmestromdichte betragen. Die Beobachtungen stimmten mit einem Wärmeübertragungsmodell überein, welches in erster Linie die Oberflächenwiederbenetzung mit der Blasenfrequenz beschreibt, überlagert durch einphasige Konvektion und einen kleinen Anteil ‘microlayer’-Verdampfung. Obwohl die Gesamtzahl der Siedekeime mit gröβer werdender Wandüberhitzung zunimmt, deaktiviert der Start neuer Keimstellen viele bei geringerer überhitzung aktive Keimstellen. B peзyльтaтe eкcпepимeHгaльHoгo иccлeдoBaHия пpoцecca пyзыpькoBoгo кипeHия Heдoгpeгoгo пoтoкa Boды пpи aтмocфepHoм дaBлeHии Ha HepжaBeющeй cтaли HaйдeHo, чтo кoeффициeHт тeплoпepeHoca yBeличиBaeтcя c pocтoм HeдoгpeBa, a тaкжe c yBeлHчeHиeм тoлщиHы cтeHки B диaпaзoHe 0,08–0,20 мм. paзмep пyзыpькa, чacгoгa зapoдышeoбpaзoBaHия и pacпpeдeлeHиe мecт oбpaзoBaHия пyзыpькoB измepялиcь пpи cкopocги Ha Bчoдe 1,7 м c−1, HeдoгpeBe 84 К, тoлщиHe cтeHки 0,08 мм и пpи тeплoBыч Hoтoкaч, cocтaBляющич 70–95% oт кpитичecкoгo пoтoкa. eкcпepимeHгы coглacyютcя c мoдeлью тeплoпepeHoca, B пepByю oчepeдь, зa cчeт peзкoгo oчлaждeHия пoBepчHocти c чacгoтoй зapoждeHия пyзыpькoB, дoпoлHяeмoй oдHoфaзHoй кoHBeкциeй и Heбoльшим Bклaдoм иcпapeHия микpocлoя. Hecмoтpя Ha тo, чгo пoлHoe чиcлo зoH зapoждeHия пyзыpькoB pacтeт c yBeличeHиeм пepeгpeBa cтeHки, BoзHикHoBeHиe HoBыч зoH дeзaктиBиpyeг мHoжecтBo paHee aкгиBHыч пpи пeбoльшoм HepeгpeBe." @default.
- W2002321343 created "2016-06-24" @default.
- W2002321343 creator A5011896616 @default.
- W2002321343 creator A5091180772 @default.
- W2002321343 date "1985-10-01" @default.
- W2002321343 modified "2023-10-14" @default.
- W2002321343 title "Subcooled flow boiling at high heat flux" @default.
- W2002321343 cites W1972168073 @default.
- W2002321343 cites W2002161258 @default.
- W2002321343 cites W2018447132 @default.
- W2002321343 cites W2023064830 @default.
- W2002321343 cites W2025700822 @default.
- W2002321343 cites W2035247448 @default.
- W2002321343 cites W2036283828 @default.
- W2002321343 cites W2044970502 @default.
- W2002321343 cites W2051361934 @default.
- W2002321343 cites W2052586903 @default.
- W2002321343 cites W2074865031 @default.
- W2002321343 cites W2102683658 @default.
- W2002321343 doi "https://doi.org/10.1016/0017-9310(85)90213-3" @default.
- W2002321343 hasPublicationYear "1985" @default.
- W2002321343 type Work @default.
- W2002321343 sameAs 2002321343 @default.
- W2002321343 citedByCount "303" @default.
- W2002321343 countsByYear W20023213432012 @default.
- W2002321343 countsByYear W20023213432013 @default.
- W2002321343 countsByYear W20023213432014 @default.
- W2002321343 countsByYear W20023213432015 @default.
- W2002321343 countsByYear W20023213432016 @default.
- W2002321343 countsByYear W20023213432017 @default.
- W2002321343 countsByYear W20023213432018 @default.
- W2002321343 countsByYear W20023213432019 @default.
- W2002321343 countsByYear W20023213432020 @default.
- W2002321343 countsByYear W20023213432021 @default.
- W2002321343 countsByYear W20023213432022 @default.
- W2002321343 countsByYear W20023213432023 @default.
- W2002321343 crossrefType "journal-article" @default.
- W2002321343 hasAuthorship W2002321343A5011896616 @default.
- W2002321343 hasAuthorship W2002321343A5091180772 @default.
- W2002321343 hasConcept C115139850 @default.
- W2002321343 hasConcept C121332964 @default.
- W2002321343 hasConcept C157777378 @default.
- W2002321343 hasConcept C159188206 @default.
- W2002321343 hasConcept C192562407 @default.
- W2002321343 hasConcept C197194406 @default.
- W2002321343 hasConcept C29700514 @default.
- W2002321343 hasConcept C37114186 @default.
- W2002321343 hasConcept C50517652 @default.
- W2002321343 hasConcept C61048295 @default.
- W2002321343 hasConcept C61441594 @default.
- W2002321343 hasConcept C97355855 @default.
- W2002321343 hasConceptScore W2002321343C115139850 @default.
- W2002321343 hasConceptScore W2002321343C121332964 @default.
- W2002321343 hasConceptScore W2002321343C157777378 @default.
- W2002321343 hasConceptScore W2002321343C159188206 @default.
- W2002321343 hasConceptScore W2002321343C192562407 @default.
- W2002321343 hasConceptScore W2002321343C197194406 @default.
- W2002321343 hasConceptScore W2002321343C29700514 @default.
- W2002321343 hasConceptScore W2002321343C37114186 @default.
- W2002321343 hasConceptScore W2002321343C50517652 @default.
- W2002321343 hasConceptScore W2002321343C61048295 @default.
- W2002321343 hasConceptScore W2002321343C61441594 @default.
- W2002321343 hasConceptScore W2002321343C97355855 @default.
- W2002321343 hasIssue "10" @default.
- W2002321343 hasLocation W20023213431 @default.
- W2002321343 hasOpenAccess W2002321343 @default.
- W2002321343 hasPrimaryLocation W20023213431 @default.
- W2002321343 hasRelatedWork W113665189 @default.
- W2002321343 hasRelatedWork W1992872739 @default.
- W2002321343 hasRelatedWork W2029509133 @default.
- W2002321343 hasRelatedWork W2096258523 @default.
- W2002321343 hasRelatedWork W2103372078 @default.
- W2002321343 hasRelatedWork W2114675510 @default.
- W2002321343 hasRelatedWork W2348469648 @default.
- W2002321343 hasRelatedWork W2917289723 @default.
- W2002321343 hasRelatedWork W2924600835 @default.
- W2002321343 hasRelatedWork W3103379360 @default.
- W2002321343 hasVolume "28" @default.
- W2002321343 isParatext "false" @default.
- W2002321343 isRetracted "false" @default.
- W2002321343 magId "2002321343" @default.
- W2002321343 workType "article" @default.