Matches in SemOpenAlex for { <https://semopenalex.org/work/W2012045144> ?p ?o ?g. }
Showing items 1 to 73 of
73
with 100 items per page.
- W2012045144 endingPage "e4" @default.
- W2012045144 startingPage "e3" @default.
- W2012045144 abstract "Mitral and tricuspid repair techniques have been well documented for rheumatic, myxomatous, and ischemic etiologies but have not been extensively described in the transplanted heart. With the limited pool of donor grafts available, valve repair may be a useful technique for extending the functionality and durability of the transplanted heart, especially if there is no coronary disease noted. A 42-year-old woman presented 21 years after orthotopic biatrial heart transplantation. She initially underwent transplantation for postpartum cardiomyopathy. She had a 6-month history of a progressive decrease in activity, weight gain, edema, orthopnea, abdominal fullness, near syncope, and palpitations. Transthoracic echocardiographic analysis showed severe tricuspid regurgitation, moderate mitral regurgitation, and biatrial enlargement in the posttransplantation heart. She had a normal ejection fraction and moderately enlarged right ventricular chamber size. Cardiac catheterization was performed and demonstrated no significant vasculopathy. Intravascular ultrasonographic analysis was not performed. The patient underwent a redo sternotomy and was started on bypass through aortic and bicaval venous cannulation. The tricuspid valve was exposed through a right atriotomy. The chordae were intact, and the leaflets were without fenestration. The mechanism of tricuspid regurgitation was annular enlargement. The mitral valve was exposed through a transseptal approach. The leaflets were normal, and the mechanism of regurgitation was annular dilation. The mitral valve was repaired with a 28-mm Geoform rigid complete annuloplasty ring, which was downsized from her anterior leaflet size of 32 mm. The patient then underwent tricuspid valve repair with a 32-mm Carpentier–Edwards classic, rigid tricuspid annuloplasty ring (Figure 1). Saline testing demonstrated residual posterior leaflet prolapse of the tricuspid valve. Bicuspidization of the posterior to septal leaflet was performed to correct this, resulting in a completely competent repair without stenosis. Her symptoms have resolved completely at 6 months' follow-up, with competent valves, as shown by means of echocardiographic analysis. Furosemide has been completely discontinued. Before valve repair, she was talking 60 mg/d of a diuretic. Additionally, her lower extremity edema has resolved. The first case of mitral valve replacement in a transplanted heart occurred 6 years after transplantation.1Copeland J.G. Rosado L.J. Sethi G. Huston C. Lee R.W. Mitral Valve Replacement six years after cardiac transplantation.Ann Thorac Surg. 1991; 51: 1014-1016Abstract Full Text PDF PubMed Scopus (22) Google Scholar Goldstein and colleagues2Goldstein D.J. Garfein E.S. Aaronson K. Zuech N. Michler R.E. Mitral valve replacement and tricuspid valve repair after cardiac transplantation.Ann Thorac Surg. 1997; 63: 1463-1465Abstract Full Text PDF PubMed Scopus (16) Google Scholar reported the first combined mitral valve replacement and tricuspid repair in a transplanted heart. They noted mild myxomatous degenerative changes of the mitral valve from a 53-year-old donor at the time of transplantation and performed a DeVega tricuspid annuloplasty. Previous to our report, there have been 2 cases documenting double-valve repair. Wijburg and associates3Wijburg E.R. Balk A.H.M.M. van Herwerden L.A. Double valve repair in a transplanted heart.J Thorac Cardiovasc Surg. 1998; 115: 250-251Abstract Full Text Full Text PDF PubMed Scopus (9) Google Scholar reported both myxomatous changes and annular dilation in both the mitral and tricuspid valves in a patient 6 years after heart transplantation. They used a partial annuloplasty band to repair the mitral valve, and they sutured the septal and posterior valve leaflets to form a bicuspid valve, which was reinforced with a DeVega annuloplasty. Recently, Yoshikawa and coworkers4Yoshikawa M. Tomari S. Usui A. Ueda Y. Surgical repair of mitral and tricuspid valves after cardiac transplantation.Asian Cardiovasc Thorac Ann. 2009; 17: 294-296Crossref PubMed Scopus (3) Google Scholar reported a case in whom a patient with endocarditis after transplantation was treated with double-valve repair. Valve dysfunction after heart transplantation is commonplace. Early after the initial transplantation, regurgitation of the atrioventricular valves is attributable to edema and poor lymphatic drainage. Later, multiple biopsy specimens of the right ventricle can also cause tricuspid chordal or leaflet injury and subsequent tricuspid regurgitation. Donor myxomatous disease and endocarditis have also been the cause of regurgitation.2Goldstein D.J. Garfein E.S. Aaronson K. Zuech N. Michler R.E. Mitral valve replacement and tricuspid valve repair after cardiac transplantation.Ann Thorac Surg. 1997; 63: 1463-1465Abstract Full Text PDF PubMed Scopus (16) Google Scholar, 4Yoshikawa M. Tomari S. Usui A. Ueda Y. Surgical repair of mitral and tricuspid valves after cardiac transplantation.Asian Cardiovasc Thorac Ann. 2009; 17: 294-296Crossref PubMed Scopus (3) Google Scholar, 5Coskun K.O. Coskun S.T. El Arousy M. Amin Parsa M. Schulz U. Deyerling W. et al.Cardiac surgery after heart transplantation: coronary artery bypass grafting and heart valve replacement.Heart Surg Forum. 2007; 10: E110-E114Crossref PubMed Scopus (6) Google Scholar The biatrial anastomosis has been implicated as the cause of subsequent annular dilatation of the mitral and tricuspid valves as a result of the atrial–ventricular size mismatch. The mitral and tricuspid valve regurgitation is attributable to the long-standing atrioventricular mismatch and subsequent annular dilatation. The experience with bicaval anastomosis appears to reduce tricuspid regurgitation.6Schnoor M. Schäfer T. Lühmann D. Sievers H.H. Bicaval versus standard technique in orthotopic heart transplantation: a systematic review and meta-analysis.J Thorac Cardiovasc Surg. 2007; 134: 1322-1331Abstract Full Text Full Text PDF PubMed Scopus (74) Google Scholar This case represents the longest interval between transplantation and double-valve repair and is one of the only reports for repair with annuloplasty alone. This is the first report of double-valve, rigid, complete ring annuloplasty in the transplanted heart. Although the patient might eventually need a retransplantation, she appears to be well 6 months after her operation, with decreasing diuretic requirement and symptom improvement, as well as echocardiographic resolution of mitral and tricuspid regurgitation. Certainly her risk for retransplantation might be increased because of the valve repair, but because the heart would be completely excised, we did not believe this represented excessive risk. Valve repair appears to be a promising technique to extend the durability and improve the symptoms of patients with a transplanted heart and valvular insufficiency." @default.
- W2012045144 created "2016-06-24" @default.
- W2012045144 creator A5014028197 @default.
- W2012045144 creator A5063406248 @default.
- W2012045144 creator A5075482375 @default.
- W2012045144 date "2010-07-01" @default.
- W2012045144 modified "2023-09-26" @default.
- W2012045144 title "Mitral and tricuspid valve repair 21 years after cardiac transplantation" @default.
- W2012045144 cites W1991746050 @default.
- W2012045144 cites W2021327135 @default.
- W2012045144 cites W2070102107 @default.
- W2012045144 cites W2078557320 @default.
- W2012045144 cites W2079870946 @default.
- W2012045144 cites W2150394875 @default.
- W2012045144 doi "https://doi.org/10.1016/j.jtcvs.2010.02.007" @default.
- W2012045144 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/20381085" @default.
- W2012045144 hasPublicationYear "2010" @default.
- W2012045144 type Work @default.
- W2012045144 sameAs 2012045144 @default.
- W2012045144 citedByCount "6" @default.
- W2012045144 countsByYear W20120451442012 @default.
- W2012045144 countsByYear W20120451442014 @default.
- W2012045144 countsByYear W20120451442015 @default.
- W2012045144 countsByYear W20120451442017 @default.
- W2012045144 countsByYear W20120451442018 @default.
- W2012045144 countsByYear W20120451442019 @default.
- W2012045144 crossrefType "journal-article" @default.
- W2012045144 hasAuthorship W2012045144A5014028197 @default.
- W2012045144 hasAuthorship W2012045144A5063406248 @default.
- W2012045144 hasAuthorship W2012045144A5075482375 @default.
- W2012045144 hasBestOaLocation W20120451441 @default.
- W2012045144 hasConcept C126322002 @default.
- W2012045144 hasConcept C141071460 @default.
- W2012045144 hasConcept C164705383 @default.
- W2012045144 hasConcept C2777543888 @default.
- W2012045144 hasConcept C2778198053 @default.
- W2012045144 hasConcept C2779946567 @default.
- W2012045144 hasConcept C2780679668 @default.
- W2012045144 hasConcept C2911091166 @default.
- W2012045144 hasConcept C71924100 @default.
- W2012045144 hasConcept C78085059 @default.
- W2012045144 hasConceptScore W2012045144C126322002 @default.
- W2012045144 hasConceptScore W2012045144C141071460 @default.
- W2012045144 hasConceptScore W2012045144C164705383 @default.
- W2012045144 hasConceptScore W2012045144C2777543888 @default.
- W2012045144 hasConceptScore W2012045144C2778198053 @default.
- W2012045144 hasConceptScore W2012045144C2779946567 @default.
- W2012045144 hasConceptScore W2012045144C2780679668 @default.
- W2012045144 hasConceptScore W2012045144C2911091166 @default.
- W2012045144 hasConceptScore W2012045144C71924100 @default.
- W2012045144 hasConceptScore W2012045144C78085059 @default.
- W2012045144 hasIssue "1" @default.
- W2012045144 hasLocation W20120451441 @default.
- W2012045144 hasLocation W20120451442 @default.
- W2012045144 hasOpenAccess W2012045144 @default.
- W2012045144 hasPrimaryLocation W20120451441 @default.
- W2012045144 hasRelatedWork W2082900536 @default.
- W2012045144 hasRelatedWork W2091793911 @default.
- W2012045144 hasRelatedWork W2130966956 @default.
- W2012045144 hasRelatedWork W2235284481 @default.
- W2012045144 hasRelatedWork W2615516258 @default.
- W2012045144 hasRelatedWork W2793069280 @default.
- W2012045144 hasRelatedWork W2993903521 @default.
- W2012045144 hasRelatedWork W3131701849 @default.
- W2012045144 hasRelatedWork W3195698793 @default.
- W2012045144 hasRelatedWork W2308882381 @default.
- W2012045144 hasVolume "140" @default.
- W2012045144 isParatext "false" @default.
- W2012045144 isRetracted "false" @default.
- W2012045144 magId "2012045144" @default.
- W2012045144 workType "article" @default.