- W2014847089 abstract "This report documents the results of Phase 1 of the ''Air Force Hydrazine Detector Characterization and Calibration Project''. A method for calibrating model MDA 7100 hydrazine detectors in the United States Air Force (AF) inventory has been developed. The calibration system consists of a Kintek 491 reference gas generation system, a humidifier/mixer system which combines the dry reference hydrazine gas with humidified diluent or carrier gas to generate the required humidified reference for calibrations, and a gas sampling interface. The Kintek reference gas generation system itself is periodically calibrated using an ORNL-constructed coulometric titration system to verify the hydrazine concentration of the sample atmosphere in the interface module. The Kintek reference gas is then used to calibrate the hydrazine monitors. Thus, coulometric titration is only used to periodically assess the performance of the Kintek reference gas generation system, and is not required for hydrazine monitor calibrations. One advantage of using coulometric titration for verifying the concentration of the reference gas is that it is a primary standard (if used for simple solutions), thereby guaranteeing, in principle, that measurements will be traceable to SI units (i.e., to the mole). The effect of humidity of the reference gas was characterized by usingmore » the results of concentrations determined by coulometric titration to develop a humidity correction graph for the Kintek 491 reference gas generation system. Using this calibration method, calibration uncertainty has been reduced by 50% compared to the current method used to calibrate hydrazine monitors in the Air Force inventory and calibration time has also been reduced by more than 20%. Significant findings from studies documented in this report are the following: (1) The Kintek 491 reference gas generation system (generator, humidifier and interface module) can be used to calibrate hydrazine detectors. (2) The Kintek system output concentration is less than the calculated output of the generator alone but can be calibrated as a system by using coulometric titration of gas samples collected with impingers. (3) The calibrated Kintek system output concentration is reproducible even after having been disassembled and moved and reassembled. (4) The uncertainty of the reference gas concentration generated by the Kintek system is less than half the uncertainty of the Zellweger Analytics' (ZA) reference gas concentration and can be easily lowered to one third or less of the ZA method by using lower-uncertainty flow rate or total flow measuring instruments. (5) The largest sources of uncertainty in the current ORNL calibration system are the permeation rate of the permeation tubes and the flow rate of the impinger sampling pump used to collect gas samples for calibrating the Kintek system. Upgrading the measurement equipment, as stated in (4), can reduce both of these. (6) The coulometric titration technique can be used to periodically assess the performance of the Kintek system and determine a suitable recalibration interval. (7) The Kintek system has been used to calibrate two MDA 7100s and an Interscan 4187 in less than one workday. The system can be upgraded (e.g., by automating it) to provide more calibrations per day. (8) The humidity of both the reference gas and the environment of the Chemcassette affect the MDA 7100 hydrazine detector's readings. However, ORNL believes that the environmental effect is less significant than the effect of the reference gas humidity. (9) The ORNL calibration method based on the Kintek 491 M-B gas standard can correct for the effect of the humidity of the reference gas to produce the same calibration as that of ZA's. Zellweger Analytics calibrations are typically performed at 45%-55% relative humidity. (10) Tests using the Interscan 4187 showed that the instrument was not accurate in its lower (0-100 ppb) range. Subsequent discussions with Kennedy Space Center (KSC) personnel also indicated that the Interscan units were not reproducible when new sensors were used. KSC had discovered that the Interscan units read incorrectly on the low range because of the presence of carbon dioxide. ORNL did not test the carbon dioxide effect, but it was found that the units did not read zero when a test gas containing no hydrazine was sampled. According to the KSC personnel that ORNL had these discussions with, NASA is phasing out the use of these Interscan detectors.« less" @default.
- W2014847089 created "2016-06-24" @default.
- W2014847089 creator A5059133352 @default.
- W2014847089 date "2003-07-07" @default.
- W2014847089 modified "2023-09-25" @default.
- W2014847089 title "An Improved Calibration Method for Hydrazine Monitors for the United States Air Force" @default.
- W2014847089 cites W2033197515 @default.
- W2014847089 doi "https://doi.org/10.2172/885782" @default.
- W2014847089 hasPublicationYear "2003" @default.
- W2014847089 type Work @default.
- W2014847089 sameAs 2014847089 @default.
- W2014847089 citedByCount "0" @default.
- W2014847089 crossrefType "report" @default.
- W2014847089 hasAuthorship W2014847089A5059133352 @default.
- W2014847089 hasBestOaLocation W20148470892 @default.
- W2014847089 hasConcept C109379892 @default.
- W2014847089 hasConcept C113196181 @default.
- W2014847089 hasConcept C121332964 @default.
- W2014847089 hasConcept C127413603 @default.
- W2014847089 hasConcept C13965031 @default.
- W2014847089 hasConcept C147789679 @default.
- W2014847089 hasConcept C165838908 @default.
- W2014847089 hasConcept C17525397 @default.
- W2014847089 hasConcept C175804951 @default.
- W2014847089 hasConcept C179104552 @default.
- W2014847089 hasConcept C184866935 @default.
- W2014847089 hasConcept C185592680 @default.
- W2014847089 hasConcept C21880701 @default.
- W2014847089 hasConcept C2776597398 @default.
- W2014847089 hasConcept C43617362 @default.
- W2014847089 hasConcept C52859227 @default.
- W2014847089 hasConcept C62520636 @default.
- W2014847089 hasConceptScore W2014847089C109379892 @default.
- W2014847089 hasConceptScore W2014847089C113196181 @default.
- W2014847089 hasConceptScore W2014847089C121332964 @default.
- W2014847089 hasConceptScore W2014847089C127413603 @default.
- W2014847089 hasConceptScore W2014847089C13965031 @default.
- W2014847089 hasConceptScore W2014847089C147789679 @default.
- W2014847089 hasConceptScore W2014847089C165838908 @default.
- W2014847089 hasConceptScore W2014847089C17525397 @default.
- W2014847089 hasConceptScore W2014847089C175804951 @default.
- W2014847089 hasConceptScore W2014847089C179104552 @default.
- W2014847089 hasConceptScore W2014847089C184866935 @default.
- W2014847089 hasConceptScore W2014847089C185592680 @default.
- W2014847089 hasConceptScore W2014847089C21880701 @default.
- W2014847089 hasConceptScore W2014847089C2776597398 @default.
- W2014847089 hasConceptScore W2014847089C43617362 @default.
- W2014847089 hasConceptScore W2014847089C52859227 @default.
- W2014847089 hasConceptScore W2014847089C62520636 @default.
- W2014847089 hasLocation W20148470891 @default.
- W2014847089 hasLocation W20148470892 @default.
- W2014847089 hasLocation W20148470893 @default.
- W2014847089 hasOpenAccess W2014847089 @default.
- W2014847089 hasPrimaryLocation W20148470891 @default.
- W2014847089 hasRelatedWork W2014847089 @default.
- W2014847089 hasRelatedWork W2068236607 @default.
- W2014847089 hasRelatedWork W2135850591 @default.
- W2014847089 hasRelatedWork W2332886396 @default.
- W2014847089 hasRelatedWork W2349011040 @default.
- W2014847089 hasRelatedWork W2376223751 @default.
- W2014847089 hasRelatedWork W2756463860 @default.
- W2014847089 hasRelatedWork W41336666 @default.
- W2014847089 hasRelatedWork W4212938952 @default.
- W2014847089 hasRelatedWork W826708699 @default.
- W2014847089 isParatext "false" @default.
- W2014847089 isRetracted "false" @default.
- W2014847089 magId "2014847089" @default.
- W2014847089 workType "report" @default.