- W2040376507 abstract "Mechanical trauma caused by percutaneous coronary intervention is a major factor contributing to subsequent cardiac events, restenosis, and the need for target lesion revascularization (TLR). To minimize this trauma, we developed a Computerized Angioplasty Pressure Sensor and Inflator Device (CAPSID) for gradual inflation. The objective of the present prospective randomized study was to examine whether the use of this novel device reduced TLR, as well as cardiac events, in patients undergoing stenting. Patients undergoing coronary stenting were eligible and randomized to receive CAPSID or standard manual percutaneous coronary intervention. In the CAPSID group, slow, gradual balloon inflation was performed using a personal computer. Patients with acute ST-elevation myocardial infarction or the need for percutaneous coronary intervention for total occlusions, left main disease, and vein grafts were excluded. Clinical follow-up for major adverse cardiac events, including death, acute myocardial infarction, and TLR, was performed at 12 months. A total of 310 patients were enrolled in the study. No significant differences were found in the clinical characteristics between the CAPSID and control groups. At 1 year of follow-up, the CAPSID group had had a significantly lower rate of major adverse cardiac events (8% vs 18%, p <0.01) driven by significantly lower rates of acute myocardial infarction (1% vs 7%, p <0.01) and TLR (5% vs 12%, p <0.05). In conclusion, gradual computerized balloon inflation using CAPSID as a platform for angioplasty and stenting significantly reduced TLR and major adverse cardiac events at 1 year in patients undergoing coronary stenting. The use of this novel device may improve outcomes in patients undergoing coronary stenting. Mechanical trauma caused by percutaneous coronary intervention is a major factor contributing to subsequent cardiac events, restenosis, and the need for target lesion revascularization (TLR). To minimize this trauma, we developed a Computerized Angioplasty Pressure Sensor and Inflator Device (CAPSID) for gradual inflation. The objective of the present prospective randomized study was to examine whether the use of this novel device reduced TLR, as well as cardiac events, in patients undergoing stenting. Patients undergoing coronary stenting were eligible and randomized to receive CAPSID or standard manual percutaneous coronary intervention. In the CAPSID group, slow, gradual balloon inflation was performed using a personal computer. Patients with acute ST-elevation myocardial infarction or the need for percutaneous coronary intervention for total occlusions, left main disease, and vein grafts were excluded. Clinical follow-up for major adverse cardiac events, including death, acute myocardial infarction, and TLR, was performed at 12 months. A total of 310 patients were enrolled in the study. No significant differences were found in the clinical characteristics between the CAPSID and control groups. At 1 year of follow-up, the CAPSID group had had a significantly lower rate of major adverse cardiac events (8% vs 18%, p <0.01) driven by significantly lower rates of acute myocardial infarction (1% vs 7%, p <0.01) and TLR (5% vs 12%, p <0.05). In conclusion, gradual computerized balloon inflation using CAPSID as a platform for angioplasty and stenting significantly reduced TLR and major adverse cardiac events at 1 year in patients undergoing coronary stenting. The use of this novel device may improve outcomes in patients undergoing coronary stenting." @default.
- W2040376507 created "2016-06-24" @default.
- W2040376507 creator A5030161910 @default.
- W2040376507 creator A5036599235 @default.
- W2040376507 creator A5037866951 @default.
- W2040376507 creator A5043552473 @default.
- W2040376507 creator A5054187249 @default.
- W2040376507 creator A5056367791 @default.
- W2040376507 creator A5057728240 @default.
- W2040376507 creator A5057910257 @default.
- W2040376507 creator A5067703732 @default.
- W2040376507 creator A5091248780 @default.
- W2040376507 date "2009-07-01" @default.
- W2040376507 modified "2023-09-25" @default.
- W2040376507 title "Effect of Gradual Computerized Angioplasty on Outcomes of Patients Undergoing Coronary Stenting" @default.
- W2040376507 cites W1437280 @default.
- W2040376507 cites W1978592486 @default.
- W2040376507 cites W1985594090 @default.
- W2040376507 cites W1987939902 @default.
- W2040376507 cites W1991235830 @default.
- W2040376507 cites W1995035288 @default.
- W2040376507 cites W2017475078 @default.
- W2040376507 cites W2019052022 @default.
- W2040376507 cites W2021111035 @default.
- W2040376507 cites W2070381506 @default.
- W2040376507 cites W2074919956 @default.
- W2040376507 cites W2170740891 @default.
- W2040376507 cites W2400441204 @default.
- W2040376507 doi "https://doi.org/10.1016/j.amjcard.2009.03.035" @default.
- W2040376507 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/19576351" @default.
- W2040376507 hasPublicationYear "2009" @default.
- W2040376507 type Work @default.
- W2040376507 sameAs 2040376507 @default.
- W2040376507 citedByCount "1" @default.
- W2040376507 crossrefType "journal-article" @default.
- W2040376507 hasAuthorship W2040376507A5030161910 @default.
- W2040376507 hasAuthorship W2040376507A5036599235 @default.
- W2040376507 hasAuthorship W2040376507A5037866951 @default.
- W2040376507 hasAuthorship W2040376507A5043552473 @default.
- W2040376507 hasAuthorship W2040376507A5054187249 @default.
- W2040376507 hasAuthorship W2040376507A5056367791 @default.
- W2040376507 hasAuthorship W2040376507A5057728240 @default.
- W2040376507 hasAuthorship W2040376507A5057910257 @default.
- W2040376507 hasAuthorship W2040376507A5067703732 @default.
- W2040376507 hasAuthorship W2040376507A5091248780 @default.
- W2040376507 hasConcept C126322002 @default.
- W2040376507 hasConcept C139059822 @default.
- W2040376507 hasConcept C164705383 @default.
- W2040376507 hasConcept C2778283817 @default.
- W2040376507 hasConcept C2778583881 @default.
- W2040376507 hasConcept C2779464278 @default.
- W2040376507 hasConcept C2780326628 @default.
- W2040376507 hasConcept C2780400711 @default.
- W2040376507 hasConcept C500558357 @default.
- W2040376507 hasConcept C71924100 @default.
- W2040376507 hasConceptScore W2040376507C126322002 @default.
- W2040376507 hasConceptScore W2040376507C139059822 @default.
- W2040376507 hasConceptScore W2040376507C164705383 @default.
- W2040376507 hasConceptScore W2040376507C2778283817 @default.
- W2040376507 hasConceptScore W2040376507C2778583881 @default.
- W2040376507 hasConceptScore W2040376507C2779464278 @default.
- W2040376507 hasConceptScore W2040376507C2780326628 @default.
- W2040376507 hasConceptScore W2040376507C2780400711 @default.
- W2040376507 hasConceptScore W2040376507C500558357 @default.
- W2040376507 hasConceptScore W2040376507C71924100 @default.
- W2040376507 hasIssue "2" @default.
- W2040376507 hasLocation W20403765071 @default.
- W2040376507 hasLocation W20403765072 @default.
- W2040376507 hasOpenAccess W2040376507 @default.
- W2040376507 hasPrimaryLocation W20403765071 @default.
- W2040376507 hasRelatedWork W1979219809 @default.
- W2040376507 hasRelatedWork W2010071730 @default.
- W2040376507 hasRelatedWork W2027779035 @default.
- W2040376507 hasRelatedWork W2069514228 @default.
- W2040376507 hasRelatedWork W2074910852 @default.
- W2040376507 hasRelatedWork W2075997693 @default.
- W2040376507 hasRelatedWork W2201668176 @default.
- W2040376507 hasRelatedWork W2399063111 @default.
- W2040376507 hasRelatedWork W2768343457 @default.
- W2040376507 hasRelatedWork W4319301322 @default.
- W2040376507 hasVolume "104" @default.
- W2040376507 isParatext "false" @default.
- W2040376507 isRetracted "false" @default.
- W2040376507 magId "2040376507" @default.
- W2040376507 workType "article" @default.