Matches in SemOpenAlex for { <https://semopenalex.org/work/W2045797685> ?p ?o ?g. }
Showing items 1 to 82 of
82
with 100 items per page.
- W2045797685 endingPage "175" @default.
- W2045797685 startingPage "171" @default.
- W2045797685 abstract "Since Brånemark first described the principle of osseointegration in the field of dentistry,1 dental implantology has become a rapidly evolving and innovative field.2 In 2004, the American Dental Association Council on Scientific Affairs cited dental implants as the “first generation of tissue engineering devices that will affect the dental profession.”3 Accordingly, a wide variety of implant materials, shapes, sizes, and surface treatments have been devised.4 Patients have become aware of the potential of dental implants; prostheses that function immediately are often desired.5 To meet this demand, implants of increasingly smaller diameter have been devised, and single-stage procedures6,7,8 with immediate functional loading2,9,10 have become available. Small-diameter implants (SDIs) are the preferred treatment modality in cases of limited anatomic geography. These implants range from 2.75–3.3 mm in width and from 8.0–15.0 mm in length.11 Specifically, SDIs are indicated for replacement of teeth with small cervical diameters and in cases of reduced interradicular bone.11 They also have been shown to be a viable alternative to bone augmentation when poor alveolar ridge width is encountered12 and in cases of restricted mesiodistal anatomy.13 Based on this in vivo and in vitro success, the mini dental implant (MDI) seems a logical successor. Smaller than their SDI counterparts, MDIs have diameters ranging from 1.8–2.4 mm. MDIs were initially designed for temporary prosthetic stabilization during the healing phase of standard implants.14 Reproducible success in this indication15,16 has led to expanded use in orthodontic anchorage,17,18 for the temporary fixation of transplanted teeth,19 in periodontal therapy,20,21 and, more recently, for long-term fixed and removable prosthetics.22,23,24,25Although the Sendax MDI (3M ESPE, OsseoSOURCE, St Paul, Minn) was the first MDI to gain approval from the U.S. Food and Drug Administration for long-term applications, several other MDI systems are available, including Hi Tec Implants (Hi Tec Implants, Herzlia, Israel) and Monorail MTI Transitional Implants (Dentatus AB, Hagersten, Sweden). The titanium-aluminum-vanadium alloy of the Sendax MDI gives it the increased strength required for long-term applications. A recent study by Kanie and colleagues26 compared the biomechanical properties of the mini transitional implant (MTI) with those of the Sendax MDI. Based on a flexural test (a fixed horizontal load was applied to the implant head), the authors determined that the MDI was 2.3 times stronger than the MTI. They concluded that the MTI is suitable for transitional use in accordance with its design, but the MDI should be used if “intensity is a priority.”26The patient was a 25-year-old male nonsmoker with a missing lower right medial tooth (#25); an intercoronal space of 3.5 mm was present (Figure 1). Both neighbor incisors had a mesiodistal diameter of 6.0 mm. The patient rejected therapy by orthodontists. Adjacent teeth were reduced with a diamond bur to a mesiodistal diameter of 5.0 mm; thus a space of 5.0 mm was created. After clinical and radiologic examination and evaluation of the retrieved information, it was decided to insert a 1.8 mm IMTEC MDI implant (15.0 mm in length; IMTEC Europe GmbH, Oberursel, Germany) (Figure 2). No connective tissue grafts were placed before implant therapy was begun, and the implant was inserted according to the usual surgical protocol (flap surgery). Flap surgery was chosen, although the standard insertion of an MDI is flapless. This was decided as the result of a critically low bone supply; clinicians wanted to be able to visually control insertion and to achieve the ideal implant position (Figures 3 and 4). The patient had a high lip line; thus no provisional prosthesis was necessary. Wound healing occurred without complications. After 3 months, the implant was loaded with a single metaloceramic crown (Figure 5).During the observation period of 1 year, no implant loss was noted. The patient was very satisfied with the result. After 1 year, no bone resorption was present (Figure 6).The history of dental implantology is one of paradigm shifts.2 Recent years have seen a movement away from submerged, 2-stage placement without functional loading to single-stage, nonsubmerged procedures with immediate functional loading.27,28,29 Accordingly, to reduce patient morbidity and convalescence, minimally invasive surgery has become routine.7,30,31 MDIs meet these new standards of implant dentistry.32 Minimally invasive oral surgery preserves the periosteal and endosteal blood supply, augmenting the osseointegration process. In addition, the flapless approach reduces bleeding, decreases postoperative discomfort, and virtually eliminates the convalescent period.33,13 In our case, the flap method was chosen despite the mentioned advantages of the flapless approach. This was decided as a result of the described critically low bone supply, so that we were able to visually control insertion and to achieve the ideal implant position. In their 5-year retrospective study, Vigolo and Givani34 present results from 52 MDIs for single-tooth restorations placed in 44 patients. Results achieved by mini implant rehabilitation were similar to those reported for standard single-tooth implant restoration. The total implant survival rate was 94.2%. Two implants were lost at second-stage surgery, and another was lost after temporary loading.34 In our case, we decided to pursue therapy without a temporary crown because of the high enough lip line of the patient; thus no provisional prosthesis was necessary in this case. The greatest disadvantage of the MDI is its poor efficacy in immediate extraction sites; the large socket diameter precludes adequate implant-bone interface. Also, a greater number of implants are recommended for MDI restorations. For single-tooth replacements, 1 MDI is used for an anterior and a bicuspid tooth, and 2 MDIs are used for a molar. With appropriate MDI training and respect for traditional implant theory, every general dentist can successfully introduce MDIs into his or her daily practice.34Implant therapies in patients with small availability of space and bone are a great challenge today. In lacking bone supply buccolingually and with reduced intercoronal space of 5.0 mm, definitive therapy with diameter-reduced MDIs is possible in individual cases. The nonablative thread architecture particularly enables gentle bone spreading and bone condensing of the implant bed and considerably improves primary stability." @default.
- W2045797685 created "2016-06-24" @default.
- W2045797685 creator A5020192443 @default.
- W2045797685 creator A5022897463 @default.
- W2045797685 creator A5059996518 @default.
- W2045797685 creator A5068170901 @default.
- W2045797685 date "2012-04-01" @default.
- W2045797685 modified "2023-09-27" @default.
- W2045797685 title "Therapy for Missing Lower Medial Incisor by Means of Reduced Diameter Implants" @default.
- W2045797685 cites W155580140 @default.
- W2045797685 cites W1580548807 @default.
- W2045797685 cites W1965311250 @default.
- W2045797685 cites W1967279360 @default.
- W2045797685 cites W1974198474 @default.
- W2045797685 cites W2001547943 @default.
- W2045797685 cites W2018262736 @default.
- W2045797685 cites W2022720222 @default.
- W2045797685 cites W2030893721 @default.
- W2045797685 cites W2071564049 @default.
- W2045797685 cites W2077153174 @default.
- W2045797685 cites W2118168930 @default.
- W2045797685 cites W2140632688 @default.
- W2045797685 cites W2149007007 @default.
- W2045797685 cites W2171164114 @default.
- W2045797685 cites W2406773777 @default.
- W2045797685 cites W2463863023 @default.
- W2045797685 cites W4256338469 @default.
- W2045797685 cites W63990501 @default.
- W2045797685 doi "https://doi.org/10.1563/aaid-joi-d-09-00138" @default.
- W2045797685 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/20662669" @default.
- W2045797685 hasPublicationYear "2012" @default.
- W2045797685 type Work @default.
- W2045797685 sameAs 2045797685 @default.
- W2045797685 citedByCount "2" @default.
- W2045797685 countsByYear W20457976852012 @default.
- W2045797685 countsByYear W20457976852015 @default.
- W2045797685 crossrefType "journal-article" @default.
- W2045797685 hasAuthorship W2045797685A5020192443 @default.
- W2045797685 hasAuthorship W2045797685A5022897463 @default.
- W2045797685 hasAuthorship W2045797685A5059996518 @default.
- W2045797685 hasAuthorship W2045797685A5068170901 @default.
- W2045797685 hasBestOaLocation W20457976851 @default.
- W2045797685 hasConcept C101414908 @default.
- W2045797685 hasConcept C141071460 @default.
- W2045797685 hasConcept C151279780 @default.
- W2045797685 hasConcept C172829275 @default.
- W2045797685 hasConcept C199343813 @default.
- W2045797685 hasConcept C2780338112 @default.
- W2045797685 hasConcept C2781411149 @default.
- W2045797685 hasConcept C29694066 @default.
- W2045797685 hasConcept C71924100 @default.
- W2045797685 hasConceptScore W2045797685C101414908 @default.
- W2045797685 hasConceptScore W2045797685C141071460 @default.
- W2045797685 hasConceptScore W2045797685C151279780 @default.
- W2045797685 hasConceptScore W2045797685C172829275 @default.
- W2045797685 hasConceptScore W2045797685C199343813 @default.
- W2045797685 hasConceptScore W2045797685C2780338112 @default.
- W2045797685 hasConceptScore W2045797685C2781411149 @default.
- W2045797685 hasConceptScore W2045797685C29694066 @default.
- W2045797685 hasConceptScore W2045797685C71924100 @default.
- W2045797685 hasIssue "2" @default.
- W2045797685 hasLocation W20457976851 @default.
- W2045797685 hasLocation W20457976852 @default.
- W2045797685 hasOpenAccess W2045797685 @default.
- W2045797685 hasPrimaryLocation W20457976851 @default.
- W2045797685 hasRelatedWork W2066520965 @default.
- W2045797685 hasRelatedWork W2163986496 @default.
- W2045797685 hasRelatedWork W2270398553 @default.
- W2045797685 hasRelatedWork W2347233032 @default.
- W2045797685 hasRelatedWork W2361566337 @default.
- W2045797685 hasRelatedWork W2371024006 @default.
- W2045797685 hasRelatedWork W2386124731 @default.
- W2045797685 hasRelatedWork W2415283086 @default.
- W2045797685 hasRelatedWork W2896606712 @default.
- W2045797685 hasRelatedWork W3009493445 @default.
- W2045797685 hasVolume "38" @default.
- W2045797685 isParatext "false" @default.
- W2045797685 isRetracted "false" @default.
- W2045797685 magId "2045797685" @default.
- W2045797685 workType "article" @default.