Matches in SemOpenAlex for { <https://semopenalex.org/work/W2055108106> ?p ?o ?g. }
Showing items 1 to 65 of
65
with 100 items per page.
- W2055108106 endingPage "1193" @default.
- W2055108106 startingPage "1192" @default.
- W2055108106 abstract "Contributed by the Heat Transfer Division for publication in the JOURNAL OF HEAT TRANSFER. Manuscript received by the Heat Transfer Division September 28, 2000; revision received April 16, 2001.The author in his Introduction gives the reasons why one should consider the two-dimensional analysis and non-insulated tip. Briefly, he states the “mathematics in the one-dimensional solution are not difficult, because of large heat transfer coefficients, the tip should no be considered insulated, and the two-dimensional solution is more difficult.” However, the following discussion will show that the above are rather superficial statements without any scientific basis. The dimensionless variables employed by the author are not appropriate, this leads to n confusing results. Given the fin geometry r1,r2, and L, the parameters k,h,he, and the temperatures Tw,T∞, these quantities should be combined to form the dimensionless parameters that characterize the heat transfer process. In the heat transfer literature these non-dimensional parameters are (1a)theratioβ=r2r2(1b)the conductiomconvection coefficientu2=r2−r12hkL=β−12hr12kL=β−12w2(1c)theparameterheh hr1k=hehBrThe parameters w2 and Br are usually called the surface conduction/convection coefficient and surface Biot number, respectively. Br enters the solution through the boundary condition, author’s equation, (2), which is written as (2)ξ=β,dθdξ+he/hBr=0.Similarly, in the two-dimensional solution Br is introduced via the author’s Eqs. (7a) and (7b). Using the above non-dimensional parameters the fin dimensionless temperature is (2a)θ=θu,β,ξ,he/hBr=θw,β,ξ,he/hBrone-dimensionalsolution(2b)θ=θu,β,ξ,ν,he/hBr,Br=θw,β,ξ,ν,he/hBr,Brtwo-dimensionalsolutionThe heat dissipated by the fin is (3a)Qfin=Qfinu,β,he/hBr=Qfinw,β,he/hBrone-dimensional(3b)Qfin=Qfinu,β,he/hBr,Br=Qfinw,β,he/hBr,Brtwo-dimensional.From the above equations one can readily derive the following fin efficiency and effectiveness: (4)efficiencyη=ηu,β,he/hBr=ηw,β,he/hBr(5)effectivenessR=Ru,β,he/hBr,Br=Rw,β,he/hBr,Br.Considering the tip to be insulated the above equations become (4a)η=ηu,β(5a)R=Ru,β,Br.One can choose any set of parameters involving u or w=u/β−1, and Br or Bi1/2=Br/w=β−1Br/u. Gardner (author’s reference) used Eq. (4a) to produce graphs of the fin’s efficiency versus u for different values of β. Razelos and Imre (author’s reference) and Netrakanti and Huang 1 employed w, and β to determine the optimum fin dimensions with variable thermal parameters. The author’s two-dimensional solution, of which that no reference is given, contains some confusing non-dimensional variables Γ, Bi, and the roots λn, that he states are determined from Eq. (6f ), not (8e) that do not exist. He never noticed that the solution always contains the product λnL. The author should have consulted Carslaw and Jaeger 2. The roots of equation (6f ) are (6)ρn=λnL=ρnBi.These roots and are tabulated in 2. One key observation is the fact that the magnitude of the roots for n>1, irrespectively of the Bi value are (7)n−1π⩽ρn⩽2n−1+1π/2.Moreover, the author should have followed 2 and express the sinρn as a function of tanρn=Bi/ρn to obtain the solution given by Eq. (2). It has been shown by Razelos and Georgiou (author’s reference) that due to the large values of ρn, the predominant term in the series for n>1 is the first one. Therefore, the two-dimensional solution consists of only one term and is not more difficult than the one-dimensional solution. In addition, in the above reference, graphs of the effectiveness are presented for different values of u and β versus Bi1/2, which show that two-dimensional solution actually reduces to the one-dimensional solution. In concluding, we should point out that the author’s comments such as “large heat transfer coefficients, thin and thick fins,” should be disregarded because all these quantities are introduced through the proper non-dimensional parameters. Also, the author’s last statement “the major difference is that the one-dimensional solution is less restrictive” whatever that means should be ignored. Today fin designers are using more sophisticated programs to design optimum or nearly optimum fins, taking into account variable thermal parameters. Therefore this paper does not offer any help due to an inappropriate set of dimensionless variables and the misleading statement “Use Fin” that appears in the Figs. 2 and 3." @default.
- W2055108106 created "2016-06-24" @default.
- W2055108106 creator A5040543058 @default.
- W2055108106 date "2001-04-16" @default.
- W2055108106 modified "2023-09-25" @default.
- W2055108106 title "Discussion: “Fin (On a Pipe) Effectiveness: One-Dimensional and Two-Dimensional” (Look, Jr., D. C., 1999, ASME J. of Heat Transfer, 121, No. 1, pp. 227–230)" @default.
- W2055108106 cites W2079142022 @default.
- W2055108106 doi "https://doi.org/10.1115/1.1413763" @default.
- W2055108106 hasPublicationYear "2001" @default.
- W2055108106 type Work @default.
- W2055108106 sameAs 2055108106 @default.
- W2055108106 citedByCount "1" @default.
- W2055108106 crossrefType "journal-article" @default.
- W2055108106 hasAuthorship W2055108106A5040543058 @default.
- W2055108106 hasConcept C10899652 @default.
- W2055108106 hasConcept C115341296 @default.
- W2055108106 hasConcept C121332964 @default.
- W2055108106 hasConcept C127413603 @default.
- W2055108106 hasConcept C172100665 @default.
- W2055108106 hasConcept C185592680 @default.
- W2055108106 hasConcept C24872484 @default.
- W2055108106 hasConcept C29700514 @default.
- W2055108106 hasConcept C41231900 @default.
- W2055108106 hasConcept C50517652 @default.
- W2055108106 hasConcept C57879066 @default.
- W2055108106 hasConcept C72948385 @default.
- W2055108106 hasConcept C78519656 @default.
- W2055108106 hasConcept C91721477 @default.
- W2055108106 hasConcept C97355855 @default.
- W2055108106 hasConceptScore W2055108106C10899652 @default.
- W2055108106 hasConceptScore W2055108106C115341296 @default.
- W2055108106 hasConceptScore W2055108106C121332964 @default.
- W2055108106 hasConceptScore W2055108106C127413603 @default.
- W2055108106 hasConceptScore W2055108106C172100665 @default.
- W2055108106 hasConceptScore W2055108106C185592680 @default.
- W2055108106 hasConceptScore W2055108106C24872484 @default.
- W2055108106 hasConceptScore W2055108106C29700514 @default.
- W2055108106 hasConceptScore W2055108106C41231900 @default.
- W2055108106 hasConceptScore W2055108106C50517652 @default.
- W2055108106 hasConceptScore W2055108106C57879066 @default.
- W2055108106 hasConceptScore W2055108106C72948385 @default.
- W2055108106 hasConceptScore W2055108106C78519656 @default.
- W2055108106 hasConceptScore W2055108106C91721477 @default.
- W2055108106 hasConceptScore W2055108106C97355855 @default.
- W2055108106 hasIssue "6" @default.
- W2055108106 hasLocation W20551081061 @default.
- W2055108106 hasOpenAccess W2055108106 @default.
- W2055108106 hasPrimaryLocation W20551081061 @default.
- W2055108106 hasRelatedWork W1005460174 @default.
- W2055108106 hasRelatedWork W1491066791 @default.
- W2055108106 hasRelatedWork W1974940952 @default.
- W2055108106 hasRelatedWork W2019072144 @default.
- W2055108106 hasRelatedWork W2061153569 @default.
- W2055108106 hasRelatedWork W2899470210 @default.
- W2055108106 hasRelatedWork W3022953567 @default.
- W2055108106 hasRelatedWork W3142233152 @default.
- W2055108106 hasRelatedWork W4293661083 @default.
- W2055108106 hasRelatedWork W4365520138 @default.
- W2055108106 hasVolume "123" @default.
- W2055108106 isParatext "false" @default.
- W2055108106 isRetracted "false" @default.
- W2055108106 magId "2055108106" @default.
- W2055108106 workType "article" @default.