Matches in SemOpenAlex for { <https://semopenalex.org/work/W2079571822> ?p ?o ?g. }
Showing items 1 to 73 of
73
with 100 items per page.
- W2079571822 endingPage "662" @default.
- W2079571822 startingPage "659" @default.
- W2079571822 abstract "This report discusses overlapping advance control systems in relation to the problems of resolution, compactness, and speed of response which are now present in varying degrees in commercially available rolling diaphragm hydraulic microdrives and which are considerations in certain applications. A mechanical microdrive was first described which achieves resolution (to 0.1 μm) and compactness by mounting a differential-screw translator concentrically within a micrometer screw. A prototype of this microdrive is approximately 6.5 × 6.5 cm, but the design of the unit allows a reduction of diameter to approximately 2 cm with no appreciable loss in resolution. Since the cost of construction is reasonable, this microdrive is a feasible and worthwhile alternative for the advance control of hydraulic systems. The application of piezoelectric transducer (PTZ) devices to impact rapid motion was then discussed: First, it was illustrated how a high load bearing PZT could be placed in series between a mechanical microdrive and a hydraulic system. This allows the wide range positioning capabilities of the mechanical microdrive to effect initial electrode control, while the high speed (“pulsed”) motion of the PZT is reserved to aid in the penetration of small cells or for exceedingly fine position adjustments. In this configuration, the PZT is located so as to avoid the drawbacks produced were such a device to be mounted on the final stage of a hydraulic system where its size would be likely to interfere. Finally, a newly designed PZT device—the inchworm—was described and its application to electrode positioning problems discussed as an additional and new alternative. Under boundary constraints defined by the cost of presently available stepping hydraulic microdrives, the alternatives discussed in this paper are certainly reasonable and the gains in resolution, compactness, and speed may therefore be viewed as attractive bonuses to be had in the event that they are demanded by experimental considerations. Dans les micromanipulateurs hydrauliques actuellement disponibles sur le marché, il existe des systèmes d'avance automatique dont la résolution, la compacité et le temps de réponse sont discutés dans ce rapport. Un micromanipulateur mécanique est tout d'abord décrit. Sa résolution atteint 0,1 μm et sa compacité est réalisée grâce à une vis différentielle concentrique montée dans la vis micrométrique. Les dimensions du prototype sont approximativement de 6,5 cm × 6,5 cm. Mais le modèle peut être réduit à environ 2 cm sans perte appréciable de résolution. Le prix de construction étant raisonnable, ce micromanipulateur constitue une solution possible et utile pour l'avance automatique des systèmes hydrauliques. L'usage de ces appareils PZT offrant un mouvement rapide est discuté: on montre comment un PZT supportant une lourde charge peut être monté en série entre un micromanipulateur mécanique et un système hydraulique. Ceci perment un large éventail de positions possibles du micromanipulateur mécanique pour effectuer le contrôle initial de l'électrode. Le mouvement rapide du PZT est alors réservé à la pénétration des petites cellules ou pour des ajustements de position extrêment fins. Dans cette optique, le PZT est placé de façon à éviter les inconvénients qu'entraine un montage sur les parties terminales du système hydraulique où la taille serait probablement un facteur de gêne. Enfin, un nouvel appareil PZT et décrit. Son application aux problèmes de position d'électrode est discutée comme une possibilité supplémentaire et nouvelle. Tenant compte des contraintes déterminées par le prix des micromanipulateurs hydrauliques actuellement disponibles, les possibilités discutées dans ce travail sont certainement raisonnables. Les gains en résolution, compacité et vitesse peuvent donc être considérés comme des améliorations qui pourraient satisfaire des besoins expérimentaux." @default.
- W2079571822 created "2016-06-24" @default.
- W2079571822 creator A5057021336 @default.
- W2079571822 creator A5085555784 @default.
- W2079571822 date "1974-12-01" @default.
- W2079571822 modified "2023-09-23" @default.
- W2079571822 title "Overlapping advance control systems for microelectrode positioning" @default.
- W2079571822 cites W1969824544 @default.
- W2079571822 cites W1990238427 @default.
- W2079571822 cites W2002309678 @default.
- W2079571822 cites W2035424260 @default.
- W2079571822 cites W2130002416 @default.
- W2079571822 cites W2415514950 @default.
- W2079571822 cites W2897643483 @default.
- W2079571822 doi "https://doi.org/10.1016/0013-4694(74)90080-7" @default.
- W2079571822 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/4140080" @default.
- W2079571822 hasPublicationYear "1974" @default.
- W2079571822 type Work @default.
- W2079571822 sameAs 2079571822 @default.
- W2079571822 citedByCount "1" @default.
- W2079571822 crossrefType "journal-article" @default.
- W2079571822 hasAuthorship W2079571822A5057021336 @default.
- W2079571822 hasAuthorship W2079571822A5085555784 @default.
- W2079571822 hasConcept C121332964 @default.
- W2079571822 hasConcept C127413603 @default.
- W2079571822 hasConcept C136229726 @default.
- W2079571822 hasConcept C154945302 @default.
- W2079571822 hasConcept C157138929 @default.
- W2079571822 hasConcept C164292776 @default.
- W2079571822 hasConcept C172707124 @default.
- W2079571822 hasConcept C192562407 @default.
- W2079571822 hasConcept C24890656 @default.
- W2079571822 hasConcept C2778603505 @default.
- W2079571822 hasConcept C41008148 @default.
- W2079571822 hasConcept C44154836 @default.
- W2079571822 hasConcept C56318395 @default.
- W2079571822 hasConcept C62611344 @default.
- W2079571822 hasConceptScore W2079571822C121332964 @default.
- W2079571822 hasConceptScore W2079571822C127413603 @default.
- W2079571822 hasConceptScore W2079571822C136229726 @default.
- W2079571822 hasConceptScore W2079571822C154945302 @default.
- W2079571822 hasConceptScore W2079571822C157138929 @default.
- W2079571822 hasConceptScore W2079571822C164292776 @default.
- W2079571822 hasConceptScore W2079571822C172707124 @default.
- W2079571822 hasConceptScore W2079571822C192562407 @default.
- W2079571822 hasConceptScore W2079571822C24890656 @default.
- W2079571822 hasConceptScore W2079571822C2778603505 @default.
- W2079571822 hasConceptScore W2079571822C41008148 @default.
- W2079571822 hasConceptScore W2079571822C44154836 @default.
- W2079571822 hasConceptScore W2079571822C56318395 @default.
- W2079571822 hasConceptScore W2079571822C62611344 @default.
- W2079571822 hasIssue "6" @default.
- W2079571822 hasLocation W20795718221 @default.
- W2079571822 hasLocation W20795718222 @default.
- W2079571822 hasOpenAccess W2079571822 @default.
- W2079571822 hasPrimaryLocation W20795718221 @default.
- W2079571822 hasRelatedWork W1970892678 @default.
- W2079571822 hasRelatedWork W2011137092 @default.
- W2079571822 hasRelatedWork W2027376017 @default.
- W2079571822 hasRelatedWork W2056892835 @default.
- W2079571822 hasRelatedWork W2100506613 @default.
- W2079571822 hasRelatedWork W2108041508 @default.
- W2079571822 hasRelatedWork W2899084033 @default.
- W2079571822 hasRelatedWork W3102344469 @default.
- W2079571822 hasRelatedWork W4242219791 @default.
- W2079571822 hasRelatedWork W4251109133 @default.
- W2079571822 hasVolume "37" @default.
- W2079571822 isParatext "false" @default.
- W2079571822 isRetracted "false" @default.
- W2079571822 magId "2079571822" @default.
- W2079571822 workType "article" @default.