Matches in SemOpenAlex for { <https://semopenalex.org/work/W2092164009> ?p ?o ?g. }
Showing items 1 to 97 of
97
with 100 items per page.
- W2092164009 endingPage "1240" @default.
- W2092164009 startingPage "1233" @default.
- W2092164009 abstract "HomeCirculationVol. 123, No. 11The National Heart, Lung, and Blood Institute Pediatric Circulatory Support Program Free AccessResearch ArticlePDF/EPUBAboutView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citationsPermissions ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toFree AccessResearch ArticlePDF/EPUBThe National Heart, Lung, and Blood Institute Pediatric Circulatory Support ProgramA Summary of the 5-Year Experience J. Timothy Baldwin, PhD, Harvey S. Borovetz, PhD, Brian W. Duncan, MD, Mark J. Gartner, PhD, Robert K. Jarvik, MD and William J. Weiss, PhD J. Timothy BaldwinJ. Timothy Baldwin From the Division of Cardiovascular Sciences, National Heart, Lung, and Blood Institute, Bethesda, MD (J.T.B.); Departments of Bioengineering and Surgery and McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA (H.S.B.); Departments of Pediatric and Congenital Heart Surgery and Biomedical Engineering, Cleveland Clinic Foundation, Cleveland, OH (B.W.D.); Ension, Inc., Pittsburgh, PA (M.J.G.); Jarvik Heart, Inc., New York, NY (R.K.J.); and Departments of Surgery and Bioengineering, Pennsylvania State University, College of Medicine, Hershey, PA (W.J.W.). Search for more papers by this author , Harvey S. BorovetzHarvey S. Borovetz From the Division of Cardiovascular Sciences, National Heart, Lung, and Blood Institute, Bethesda, MD (J.T.B.); Departments of Bioengineering and Surgery and McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA (H.S.B.); Departments of Pediatric and Congenital Heart Surgery and Biomedical Engineering, Cleveland Clinic Foundation, Cleveland, OH (B.W.D.); Ension, Inc., Pittsburgh, PA (M.J.G.); Jarvik Heart, Inc., New York, NY (R.K.J.); and Departments of Surgery and Bioengineering, Pennsylvania State University, College of Medicine, Hershey, PA (W.J.W.). Search for more papers by this author , Brian W. DuncanBrian W. Duncan From the Division of Cardiovascular Sciences, National Heart, Lung, and Blood Institute, Bethesda, MD (J.T.B.); Departments of Bioengineering and Surgery and McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA (H.S.B.); Departments of Pediatric and Congenital Heart Surgery and Biomedical Engineering, Cleveland Clinic Foundation, Cleveland, OH (B.W.D.); Ension, Inc., Pittsburgh, PA (M.J.G.); Jarvik Heart, Inc., New York, NY (R.K.J.); and Departments of Surgery and Bioengineering, Pennsylvania State University, College of Medicine, Hershey, PA (W.J.W.). Search for more papers by this author , Mark J. GartnerMark J. Gartner From the Division of Cardiovascular Sciences, National Heart, Lung, and Blood Institute, Bethesda, MD (J.T.B.); Departments of Bioengineering and Surgery and McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA (H.S.B.); Departments of Pediatric and Congenital Heart Surgery and Biomedical Engineering, Cleveland Clinic Foundation, Cleveland, OH (B.W.D.); Ension, Inc., Pittsburgh, PA (M.J.G.); Jarvik Heart, Inc., New York, NY (R.K.J.); and Departments of Surgery and Bioengineering, Pennsylvania State University, College of Medicine, Hershey, PA (W.J.W.). Search for more papers by this author , Robert K. JarvikRobert K. Jarvik From the Division of Cardiovascular Sciences, National Heart, Lung, and Blood Institute, Bethesda, MD (J.T.B.); Departments of Bioengineering and Surgery and McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA (H.S.B.); Departments of Pediatric and Congenital Heart Surgery and Biomedical Engineering, Cleveland Clinic Foundation, Cleveland, OH (B.W.D.); Ension, Inc., Pittsburgh, PA (M.J.G.); Jarvik Heart, Inc., New York, NY (R.K.J.); and Departments of Surgery and Bioengineering, Pennsylvania State University, College of Medicine, Hershey, PA (W.J.W.). Search for more papers by this author and William J. WeissWilliam J. Weiss From the Division of Cardiovascular Sciences, National Heart, Lung, and Blood Institute, Bethesda, MD (J.T.B.); Departments of Bioengineering and Surgery and McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA (H.S.B.); Departments of Pediatric and Congenital Heart Surgery and Biomedical Engineering, Cleveland Clinic Foundation, Cleveland, OH (B.W.D.); Ension, Inc., Pittsburgh, PA (M.J.G.); Jarvik Heart, Inc., New York, NY (R.K.J.); and Departments of Surgery and Bioengineering, Pennsylvania State University, College of Medicine, Hershey, PA (W.J.W.). Search for more papers by this author Originally published22 Mar 2011https://doi.org/10.1161/CIRCULATIONAHA.110.978023Circulation. 2011;123:1233–1240The Pediatric Circulatory Support Program (PCSP) of the National Heart, Lung, and Blood Institute (NHLBI) was established to fund the development of novel circulatory support devices for children with medically refractory heart failure.1 Before this, developers of circulatory support devices found little incentive to enter the pediatric market because of the small patient numbers that are generally insufficient to justify the significant costs required to develop these devices. As a result of the lack of availability of new devices for circulatory support of pediatric patients, extracorporeal membrane oxygenation (ECMO), which first had been used clinically in the 1960s, remained the most commonly used modality to support these critically ill children during the next 40 years.2 The most attractive feature of ECMO for pediatric circulatory support is its ability to be used in even the smallest infants and neonates. However, ECMO support is characterized by thromboembolic complications and sepsis in a significant percentage of patients.3 Perhaps most importantly, ECMO has generally only been suitable for short-term support, limiting its usefulness as a bridge to transplantation, and the size and extracorporeal configuration of the system components usually limit its use to the intensive care unit setting and preclude ambulation and rehabilitation during support.In recognition of the limitations of the existing devices for pediatric mechanical circulatory support and the limitations for the entry of device companies into the pediatric market, the NHLBI established the PCSP to “perform basic and applied research to develop novel circulatory assist devices or other bioengineered systems for infants and children with congenital and acquired cardiovascular disease who experience cardiopulmonary failure and circulatory collapse.”4 Because the PCSP was a development program for new devices to address a broad goal (circulatory support for pediatric heart failure) rather than for a specific design, and because funding various promising approaches would improve the chances of successfully achieving the objectives of the program, proposals were solicited under a Broad Agency Announcement. Broad Agency Announcements are used, as in this case, when proposals with varying scientific or technical approaches are anticipated. After receipt, review, and assessment of the proposals submitted in response to the Broad Agency Announcement, contracts totaling >$20 million were awarded by the NHLBI in the spring of 2004 to 5 contractors to develop a family of pediatric circulatory support devices (Table 1). Funding support for the PCSP concluded in 2009. In 2006, a summary report was published that described these devices and the development goals of their respective programs as the PCSP was initiated.1 Because the PCSP was a development program involving different devices, the design processes, the in vitro and in vivo tests and analyses, and the goals for those tests varied between contractors. However, to make the most of the program, contractors participated in monthly conference calls, attended and presented their progress at annual meetings, and shared quarterly progress reports. These activities provided a means for each of the contractor teams to learn from and leverage the progress made by the other contractors and, as appropriate, to modify their approach and improve their device. The present report provides a summary of progress for each of the contractors at the conclusion of this program, including a sampling of some of the test results and analyses. The report concludes with the plans for achieving clinical application of these and other promising pediatric circulatory support devices.Table 1. National Heart, Lung, and Blood Institute Pediatric Circulatory Support Program Contractors and DevicesProgramDeviceUniversity of PittsburghPediaFlow pediatric ventricular assist deviceCleveland ClinicPediPumpEnsion, IncPediatric Cardiopulmonary Assist SystemJarvik Heart, IncPediatric Jarvik 2000Penn State UniversityPediatric ventricular assist deviceThe PediaFlow Pediatric Ventricular Assist Device (University of Pittsburgh)A consortium led by the University of Pittsburgh undertook an ambitious program that relied on fundamental bioengineering principles to develop, de novo, a miniature blood pump specifically intended for the youngest heart failure patients. Through the PCSP, the consortium produced the PediaFlow PF3, a miniaturized magnetically levitated blood pump (Figure 1). With a flow rate range between 0.3 and 1.5 L/min and a volume approximately that of an AA cell battery (Table 2), the clinical PediaFlow ventricular assist device (VAD) has been developed to meet the goal of the PCSP to provide circulatory support for neonates, infants, and children weighing >25 kg who experience cardiac failure and circulatory collapse due to congenital and/or acquired cardiovascular disease.Download figureDownload PowerPointFigure 1. The family of devices developed under the Pediatric Circulatory Support Program. A, The PediPump ventricular assist device showing application for biventricular support; B, PediaFlow ventricular assist system; C, Penn State infant pediatric ventricular assist device; D, Ension's Pediatric Cardiopulmonary Assist System with prototype controller console; and E, infant-size pediatric Jarvik 2000 showing thrombus-free bearings after 5 weeks in a lamb animal model.Table 2. National Heart, Lung, and Blood Institute Pediatric Circulatory Support Program Device CharacteristicsParameterPediaFlow PF3PediPumpJarvik 2000Ension pCAS*Penn State Pediatric Ventricular Assist DeviceInfantChildInfantChild Diameter, mm19.610.510.51876NANA Length, mm6064.55259190NANA Total volume, mL16.654129666150 Total mass, g5016.5113584367.575 Priming volume, mL2.30.6141051025 Maximum speed, rpm ×1000151540163NANA Maximum flow rate, L/min1.53.0333.01.63.3NA indicates not applicable.*The Pediatric Cardiopulmonary Assist System (pCAS) is an extracorporeal membrane oxygenation device.The first 2 designs (the PF1 and PF2 models) focused on demonstrating feasibility and improving the hemodynamic characteristics, particularly increasing the peak flow rate to 2.0 L/min against a pressure head of 80 mm Hg. This was accomplished by the development of an optimized 4-pole motor that provided the required torque. Operation was demonstrated to be stable at pump outputs between 0.25 and 2.0 L/min against a pressure load of 80 mm Hg. Progress was also made in reducing the size, profile, and weight of the PediaFlow pump. Through design optimization, the PF2 pump occupied approximately half of the volume (35.5 mL) associated with the housings for the PF1 pump (63.6 mL). As designed, the PF2 pump would be implantable in patients weighing ≥10 kg but would be problematic for implantation in the smallest patients.The PF3 design represents the latest enhancements of the PediaFlow VAD. The system overcame size limitations of the earlier PF1 and PF2 designs by being uniquely configured for supercritical operation at rotational speeds beyond those associated with resonance frequencies. This modification resulted in dramatic size reduction, and therefore the PF3 system takes less than half of the volume of the previous versions. As a result, the PediaFlow pediatric VAD is capable of full implantation in the left upper quadrant behind the left rectus abdominus muscle in the smallest patients (<5 kg).During the program, 9 in vivo ovine PediaFlow implantation studies ranging from acute (6 hours) to chronic (30 days and 72 days, electively terminated) were conducted. Throughout each of the chronic studies, rheological and biocompatibility studies were completed, and the animal's physiological status and serum biochemistry were monitored. Nearly all measured hemodynamic, biochemical, and biocompatibility values either fell within the literature reference range for these parameters in sheep or demonstrated a nearly identical temporal course as observed in sham control studies. Assays were specifically developed to quantify circulating activated ovine platelets, and these assays have been utilized in each PediaFlow implantation.5–7Figure 2 demonstrates platelet activation in a PF2 implantation before and after stimulation with adenosine diphosphate and platelet activating factor. Platelet activation rose modestly after surgery and quickly returned to baseline. Platelets could be stimulated to high activation levels with adenosine diphosphate and platelet activating factor, signifying conserved platelet function during the implantation. This temporal response was similar to the platelet activation results in the sham control studies and PF3 implantations, suggesting attractive platelet biocompatibility.7Download figureDownload PowerPointFigure 2. Platelet activation in a lamb animal model using an earlier version of the PediaFlow ventricular assist system after stimulation of blood with 20 μmol/L adenosine diphosphate (ADP) and 10 μmol/L platelet activating factor (PAF). Platelet function with the implanted PediaFlow ventricular assist system appears to be conserved, as evidenced by the finding that platelets could be stimulated to high activation levels with adenosine diphosphate and platelet activating factor; similar results were observed in sham studies.The PediPump (Cleveland Clinic)The initial objectives of Cleveland Clinic's development program were to create an implantable VAD that would be small enough to allow implantation in newborns yet capable of providing hemodynamic support for children up to 25 kg. The resulting PediPump is a novel pediatric VAD based on a design for transcatheter applications in adults that appeared suitable for pediatric application because of its small size and hemodynamic targets for support (Figure 1). The PediPump employs a mixed-flow rotary pump with a rotor that is suspended on passive magnetic bearings as in the initial design for the adult transcatheter pump.8–11 Primary blood flow is powered by a 3-blade impeller, exits through the annulus containing the outflow stator blades, and passes over the motor, which provides motor cooling. Absence of seals in this design removes the need for external purge flows and reduces wear, making the pump suitable for prolonged periods of support.The PediPump has undergone incremental design improvements throughout the PCSP support period while retaining the same fundamental pump design. These included refinements to the pump's magnetic bearing design, motor design, wash-flow path, axial touch-point design, and electric/thermal insulation. The most recent version of the PediPump, the Mark IV, includes improvements in design and manufacture of the magnetic bearings, which allows reduction in the axial dimension of the pump that now measures 64.5 mm in length by 10.5 mm in diameter.The PediPump development program also sought to address anticipated anatomic fit issues of VAD implantation in children. Initial work in this program created on-screen 3-dimensional reconstructions from clinically obtained computed tomography and magnetic resonance imaging studies.12 This approach to anatomic 3-dimensional reconstructions was subsequently used in a sheep model to aid in planning for device fitting before the initiation of the in vivo testing program for the PediPump described below.13,14 Subsequent studies have combined digital renderings of the PediPump with computed tomography– and magnetic resonance imaging–derived 3-dimensional studies– to perform virtual fitting, whereby various approaches to implantation can be evaluated on screen.15 (Figure 3) This approach should be particularly useful as an aid to preoperative planning in the smallest pediatric patients in whom anatomic fit will be most difficult, as well as in patients with extreme anatomic variants often encountered in congenital heart disease.Download figureDownload PowerPointFigure 3. Model of the PediPump in a right ventricular assist device (RVAD) configuration virtually positioned on the diaphragmatic surface of the heart in a 3-dimensional reconstruction derived from a computed tomography scan of an 8-month-old patient with tetralogy of Fallot. Ao indicates aorta; PA, pulmonary artery; RA, right atrium; and RV, right ventricle. Reproduced with permission from Saeed et al.15Animal testing of the PediPump began with five 6-hour acute studies in a sheep model that were used to develop the implantation procedures and evaluate basic performance, including in vivo hemolysis and deposition.16 Nine chronic implantations have been performed, with a number of these animals surviving to completion of the target 30-day period of study. Implantation was technically easy, and surviving animals have tolerated subsequent recovery well. Hemodynamic performance of the PediPump was stable throughout the period of chronic in vivo support in all animals and appeared to be suitable for the physiological envelope initially targeted for the development program, with flows averaging 1.7 to 2.0 L/min with a pressure rise of 50 to 60 mm Hg. Importantly, minimal hemolysis has been observed during the entire in vivo testing program. Some animals early in the chronic support series developed a cap of deposition on the rear rotor touch point. This was addressed by a redesign of the rear touch point as well as a change to more biocompatible materials in this region of the pump. In summary, progress in the PediPump development program has created an important foundation of preclinical data as the PediPump program progresses to clinical trials in its next stage of development.Pediatric Cardiopulmonary Assist System (Ension, Inc)Ension's Pediatric Cardiopulmonary Assist System (pCAS) has been developed as a next-generation ECMO system. The pCAS improves on the current state of ECMO by offering improved blood compatibility, reduced surface area and priming volume, rapid deployment, and a simplified system configuration that facilitates parent-child bonding and patient transport.The pCAS (Figure 1) consists of a pump oxygenator, controller console, and ancillary components such as venous and arterial cannulas and an arterial bubble trap. It is a compact, integrated device consisting of an impeller directly integrated to a blood oxygenator with a turning diffuser. The system is designed to provide partial or complete cardiopulmonary support to patients from 2 to 25 kg. Although the period of intended use is 2 weeks for a single disposable blood-contacting pCAS pump oxygenator, extended support is accommodated through pump oxygenator change-out, typically taking <5 minutes.Blood-contacting surfaces of the pump oxygenator incorporate Ension's bioactive surface. This surface has been specifically engineered to be stable, bioactive, cost-effective, permeable to oxygen and carbon dioxide, and applicable to a variety of fiber materials such as microporous polypropylene and polymethylpentene. A bioactive surface is also applied to the blood tubing and cannulas, yielding a circuit with tip-to-tip bioactive surface modification. Cannulation can be via neck vessels in infants, femoral vessels in children with sufficient size, or chest cannulation in surgical patients. The pCAS pump oxygenator was designed for use with a variety of different cannulas (from 8F to 22F) because of the wide range of clinical preferences and practices and patient sizes.The touch screen–based pCAS control console has been designed to provide simple and reliable operation. Control console functions include display and regulation of pump speed, flow, and other operational parameters, monitoring the system for fault conditions.Development of the pCAS has been guided by risk management, reliability, and human factors analyses as well as functionality, biocompatibility, and clinical requirements. Fabrication processes have been established, refined, and validated as part of the product development and prototype production processes. Over the 5-year period of development, design iterations of the pCAS pump oxygenator and controller console have been fabricated and tested extensively both in vitro and in vivo. In vitro data have demonstrated the ability of the pCAS pump oxygenator to achieve required blood flow rates and pressures and to exchange oxygen and carbon dioxide with minimal blood damage. Ension has utilized 2 different animal models for in vivo evaluations. Acute in vivo system testing in piglets ranging from 7.9 to 11.6 kg has demonstrated that the pCAS provides appropriate hemodynamic support for the small patients in the target population with the use of appropriately sized cannulas. Specifically, blood flow rates of up to 1.2 L/min and oxygenation saturation levels of 100% were achieved with the use of 10F venous and 8F arterial cannulas. Three-day studies in calves have demonstrated improved blood compatibility.The Jarvik 2000 Infant and Child VADs (Jarvik Heart, Inc)Jarvik Heart, Inc. has developed both child-size and infant-size intraventricular blood pumps generally patterned after the Jarvik 2000 adult model (Figure 1). The final-design pumps are very small, provide flow from 0.25 to 3 L/min, and have not caused hemolysis, platelet activation, or pump thrombosis in lamb implantations.During the first 3 years of the 5-year National Institutes of Health development program, pump stoppage due to bearing thrombus was a major barrier to success. This was first observed when several pin-in-sleeve bearing designs seized during chronic animal studies. The bearing thrombus problem was overcome only after the development of a new type of miniature ceramic blood-immersed bearing termed the cone bearing (Figure 4). During the program, 21 animal implantations intended for long-term survival were conducted. With the use of the original bearings with the child and infant models, 75% (9 of 12 pumps implanted) failed because of bearing seizure from thrombus or bearing fracture, usually within 3 weeks. With the new cone bearing design, animals survived with elective termination up to 70 days. No pumps failed because of bearing problems with the new bearings, and only 1 of 9 implantation cases had thrombus within the pump. However, this was secondary to infection and thrombosis of the outflow graft near the flow probe. Thus, the cone bearings were successful in all cases, and the pump was thrombus free in 89% of the implantations. Accelerated durability testing of the cone bearings for the child-size pump for >3 years is ongoing, with no failures and measured bearing surface wear of only 1 μm/5 y.Download figureDownload PowerPointFigure 4. The cone bearing developed for the infant and child Jarvik 2000 ventricular assist device (VAD). The novel design eliminated thrombosis in the bearing during chronic animal studies.The infant-size Jarvik 2000 is the smallest implantable blood pump. The size of an AAA battery, it is small enough to implant in the ventricular apex of 3.5-kg newborns, yet it has flow capacity of >3 L/min, which is sufficient for children up to 25 kg. Animal implantations have shown that the pump remains free of thrombus and operates at low power (3 to 5 W) without causing hemolysis. The pump incorporates all of the requirements for a long-term implant, including welded hermetic sealing of the motor stator and rotor magnet, miniature hermetic feed-throughs for the power cables, a very-long-life conical ceramic bearing design, and pacemaker-type, high-flex life power cables from the external controller to the implanted blood pump.Work is underway to complete a new control system with important user-friendly features, which is expected to be especially useful for support of children living at home.The Penn State Pediatric VAD (Pennsylvania State University–Hershey Medical Center)The Penn State pediatric VAD is a pneumatically actuated pulsatile pump (Figure 1) based on the design of the Pierce-Donachy adult VAD (Thoratec PVAD) developed at Penn State. The Penn State pediatric VAD has been developed in 2 sizes: a 12-mL stroke volume infant VAD with 6 and 8 mm cannulas and a 25-mL stroke volume child VAD with 8 and 10 mm cannulas.17 The pneumatic pulsatile VADs are flexible in their application and may be utilized for left, right, or biventricular support. Pump filling is detected by measuring the driveline airflow, enabling a full-to-empty automatic rate control, resulting in an increase in pump rate with increasing inlet pressure. This automatic preload sensitivity allows maximum flow and ventricular unloading to be achieved while limiting excessive inlet suction and provides safe left atrial pressure control in biventricular support. The pump is designed with the option of paracorporeal placement or implantation. A duration of support in excess of 1 year is expected to be achieved with this design. Improvements to the devices during the program include a new Björk-Shiley Monostrut custom valve (manufactured in-house), a redesigned diaphragm, and better seals.The primary design objective has been to produce a device with low thrombogenic risk. This is especially challenging because the fluid mechanics in small-scale devices favor low wall shear rates and have a higher propensity for clot formation relative to adult-size devices. Significant efforts have been made in understanding the spatial and temporal properties of blood flow in the pump and cannulas, with special attention to the valves, with the use of particle image velocimetry18 and a viscoelastic blood analog.19 Wall shear rates were calculated from the data to quantify wall washing (Figure 5). The Björk-Shiley Monostrut valve was selected because the results revealed that it provided a stronger and more sustained rotational flow because of the major orifice inlet jet as well as lower outlet valve regurgitation than the Carbomedics valve, which was also evaluated.20 Particle image velocimetry was also used to evaluate the effect of reduced flow rate during weaning.21Download figureDownload PowerPointFigure 5. An example of a flow map (A) and the corresponding wall shear rate map (B). The section highlighted and labeled S3 is the surface shown in the wall shear map in B. An example wall shear rate (profile B) is shown, in which positive shear is defined in the clockwise direction and negative shear is in the counterclockwise direction. The oval highlights the time step shown in the flow map A. The shear rate is normalized by the threshold shear of 500 s−1, so that 1 to −1 on the shear map is equivalent to 500 s−1 to −500 s−1. Vel Mag indicates velocity magnitude.The Penn State investigators made substantial progress in developing animal models for studies of pediatric VADs. Chronic animal studies of the infant pump were completed in 11 lambs and 4 goats. One acute study, 3 surgical shams, and 4 hematologic control studies were also completed. A major challenge in the early studies was atelectasis and respiratory failure, not related to VAD function, which required protocol improvements.22,23 A stable animal model in the 20- to 25-kg lamb was achieved subsequently. This model demonstrated healthy survival to elective termination at 4 weeks in 5 of the 7 most recent studies (duration, 5 to 41 days; mean, 26.1 days).The results from the animal studies are promising. Hemolysis was not evident in animal testing, and in vitro hemolysis testing with bovine blood demonstrated a normalized index of hemolysis similar to adult pulsatile VADs. Likewise, thromboembolism was also not evident in the animal testing. In 1 group of animals (the activated partial thromboplastin time group; n=4), unfractionated heparin was titrated to achieve a therapeutic activated partial thromboplastin time of 2 times normal, which is a common approach in humans.6 As shown in Figure 6, thromboelastography in this group indicated hypocoagulability despite a therapeutic activated partial thromboplastin time, raising concern that the in vivo testing protocol was less challenging (in terms of thromboembolism) than the expected clinical use. Therefore, a reduced-heparin thromboelastography group (n=3) in which heparin was titrated to achieve a target thromboelastography R-time of 2 times normal was initiated (thromboelastography-based protocols are used in some centers24). Figure 6 reveals that the heparin activity, as measured by anti-factor Xa, was not detectable in the reduced-heparin thromboelastography group. No thromboembolism was observed in either group. The kidneys were grossly normal except for cortical depressions and fibrosis consistent with old infarcts in 2 cases (thromboelastography group) and a recent renal infarct in 1 animal with a cecal abscess and fever (activated partial thromboplastin time group). These results are generally consistent with previous preclinical studies of successful adult VADs, even at low levels of heparin anticoagulation.Download figureDownload PowerPointFigure 6. Left, The heparin dose in the reduced-heparin thromboelastography protocol (TEG) group was approximately one half that of the activated partial thromboplastin time (aPTT) group, and circulating heparin (anti-factor Xa [antiXa]) was barely" @default.
- W2092164009 created "2016-06-24" @default.
- W2092164009 creator A5023178616 @default.
- W2092164009 creator A5032010141 @default.
- W2092164009 creator A5057083001 @default.
- W2092164009 creator A5064736695 @default.
- W2092164009 creator A5075570851 @default.
- W2092164009 creator A5076844722 @default.
- W2092164009 date "2011-03-22" @default.
- W2092164009 modified "2023-09-26" @default.
- W2092164009 title "The National Heart, Lung, and Blood Institute Pediatric Circulatory Support Program" @default.
- W2092164009 cites W1848461758 @default.
- W2092164009 cites W1969876513 @default.
- W2092164009 cites W1982100984 @default.
- W2092164009 cites W1987099057 @default.
- W2092164009 cites W1997145179 @default.
- W2092164009 cites W2000298572 @default.
- W2092164009 cites W2003900447 @default.
- W2092164009 cites W2004274128 @default.
- W2092164009 cites W2004481100 @default.
- W2092164009 cites W2012867906 @default.
- W2092164009 cites W2014658515 @default.
- W2092164009 cites W2014804278 @default.
- W2092164009 cites W2017120411 @default.
- W2092164009 cites W2023045915 @default.
- W2092164009 cites W2043476313 @default.
- W2092164009 cites W2046364471 @default.
- W2092164009 cites W2052857876 @default.
- W2092164009 cites W2061534791 @default.
- W2092164009 cites W2079338696 @default.
- W2092164009 cites W2080435502 @default.
- W2092164009 cites W2100761692 @default.
- W2092164009 cites W2141870765 @default.
- W2092164009 cites W2147894732 @default.
- W2092164009 doi "https://doi.org/10.1161/circulationaha.110.978023" @default.
- W2092164009 hasPubMedCentralId "https://www.ncbi.nlm.nih.gov/pmc/articles/3066431" @default.
- W2092164009 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/21422399" @default.
- W2092164009 hasPublicationYear "2011" @default.
- W2092164009 type Work @default.
- W2092164009 sameAs 2092164009 @default.
- W2092164009 citedByCount "97" @default.
- W2092164009 countsByYear W20921640092012 @default.
- W2092164009 countsByYear W20921640092013 @default.
- W2092164009 countsByYear W20921640092014 @default.
- W2092164009 countsByYear W20921640092015 @default.
- W2092164009 countsByYear W20921640092016 @default.
- W2092164009 countsByYear W20921640092017 @default.
- W2092164009 countsByYear W20921640092018 @default.
- W2092164009 countsByYear W20921640092019 @default.
- W2092164009 countsByYear W20921640092020 @default.
- W2092164009 countsByYear W20921640092021 @default.
- W2092164009 countsByYear W20921640092022 @default.
- W2092164009 countsByYear W20921640092023 @default.
- W2092164009 crossrefType "journal-article" @default.
- W2092164009 hasAuthorship W2092164009A5023178616 @default.
- W2092164009 hasAuthorship W2092164009A5032010141 @default.
- W2092164009 hasAuthorship W2092164009A5057083001 @default.
- W2092164009 hasAuthorship W2092164009A5064736695 @default.
- W2092164009 hasAuthorship W2092164009A5075570851 @default.
- W2092164009 hasAuthorship W2092164009A5076844722 @default.
- W2092164009 hasBestOaLocation W20921640091 @default.
- W2092164009 hasConcept C126322002 @default.
- W2092164009 hasConcept C164705383 @default.
- W2092164009 hasConcept C177713679 @default.
- W2092164009 hasConcept C2777714996 @default.
- W2092164009 hasConcept C71924100 @default.
- W2092164009 hasConcept C72859922 @default.
- W2092164009 hasConceptScore W2092164009C126322002 @default.
- W2092164009 hasConceptScore W2092164009C164705383 @default.
- W2092164009 hasConceptScore W2092164009C177713679 @default.
- W2092164009 hasConceptScore W2092164009C2777714996 @default.
- W2092164009 hasConceptScore W2092164009C71924100 @default.
- W2092164009 hasConceptScore W2092164009C72859922 @default.
- W2092164009 hasIssue "11" @default.
- W2092164009 hasLocation W20921640091 @default.
- W2092164009 hasLocation W20921640092 @default.
- W2092164009 hasLocation W20921640093 @default.
- W2092164009 hasLocation W20921640094 @default.
- W2092164009 hasOpenAccess W2092164009 @default.
- W2092164009 hasPrimaryLocation W20921640091 @default.
- W2092164009 hasRelatedWork W1965567535 @default.
- W2092164009 hasRelatedWork W1977370716 @default.
- W2092164009 hasRelatedWork W1984162378 @default.
- W2092164009 hasRelatedWork W1985548875 @default.
- W2092164009 hasRelatedWork W2012725014 @default.
- W2092164009 hasRelatedWork W2024203088 @default.
- W2092164009 hasRelatedWork W2398841301 @default.
- W2092164009 hasRelatedWork W2410417953 @default.
- W2092164009 hasRelatedWork W2437410770 @default.
- W2092164009 hasRelatedWork W3005652238 @default.
- W2092164009 hasVolume "123" @default.
- W2092164009 isParatext "false" @default.
- W2092164009 isRetracted "false" @default.
- W2092164009 magId "2092164009" @default.
- W2092164009 workType "article" @default.