Matches in SemOpenAlex for { <https://semopenalex.org/work/W2110396376> ?p ?o ?g. }
Showing items 1 to 64 of
64
with 100 items per page.
- W2110396376 endingPage "519" @default.
- W2110396376 startingPage "518" @default.
- W2110396376 abstract "We read with great interest the article “Angiographic and Electron-Beam Computed Tomography Studies of Retrograde Cardioplegia via the Coronary Sinus” authored by Farge and associates.1Farge A Mousseaux E Acar C et al.Angiographic and electron-beam computed tomography studies of retrograde cardioplegia via the coronary sinus.J Thorac Cardiovasc Surg. 1996; 112: 1046-1053Abstract Full Text Full Text PDF PubMed Scopus (11) Google Scholar Since 1993 our laboratory has been addressing the distribution of cardioplegic solution delivered via the coronary sinus using explanted human hearts. Many of the authors' findings are similar to our previously published results; however, there are significant differences that we believe are worthy of discussion. Using their experimental technique, the authors could not demonstrate flow to the right ventricular free wall, regardless of whether the experimental contrast solution was delivered with the coronary sinus occluded at its ostium or not. In our article, “Gross and Microvascular Distribution of Retrograde Cardioplegia in Explanted Human Hearts,”2Gates RN Laks H Drinkwater DC et al.Gross and microvascular distribution of retrograde cardioplegia in explanted human hearts.Ann Thorac Surg. 1993; 56: 410-417Abstract Full Text PDF PubMed Scopus (52) Google Scholar we found clear anatomic gross and microvascular histologic evidence for right ventricular free wall perfusion when cardioplegic solution was delivered with the coronary sinus occluded (Fig. 1). In that study we used an inert intracapillary marker (NTB-2) to qualitatively examine retrograde distribution. In another manuscript, “Coronary Sinus Ostial Occlusion During Retrograde Delivery of Cardioplegic Solution Significantly Improves Cardioplegic Distribution and Efficacy,”3Rudis E Gates RN Laks H et al.Coronary sinus ostial occlusion during retrograde delivery of cardioplegic solution significantly improves cardioplegic distribution and efficacy.J Thorac Cardiovasc Surg. 1995; 109: 941-947Abstract Full Text Full Text PDF PubMed Scopus (18) Google Scholar we also found clear evidence of capillary perfusion of right ventricular free wall myocardium. In this experiment colored microspheres were added to cardioplegic solution, which was delivered retrogradely with the coronary sinus either open or occluded, to quantitatively determine regional microvascular flow. Right ventricular flow, as well as posterior intraventricular septal flow, was greatly augmented as a result of coronary sinus occlusion. Even without occlusion, however, right ventricular flow was documented. We believe these differing experimental conclusions are likely the result of differing experimental models. Flow through the coronary venous system and subsequent capillary or thebesian systems is governed by the resistance of the vascular beds and the viscosity of the fluid delivered. In our model, explanted human hearts are arrested by cold cardioplegia, excised and transferred to the laboratory, and subjected to experimental cardioplegic solutions within 20 minutes. We believe this model properly mimics the clinical situation, and normal operative coronary venous vascular resistance is anticipated. The authors use cadaveric hearts for experimentation, but they do not state how these are obtained and preserved and within what time frame they are examined. Such conditions, particularly if ischemia is involved, can greatly alter vascular resistance. In our microsphere studies, the microspheres are delivered within human blood cardioplegic solution. In our anatomic NTB-2 studies, the experimental solution was prepared so that its pH, viscosity, and osmolality all resembled blood cardioplegic solution. These properties of the authors' experimental solution are not mentioned within the article. Such variables, particularly viscosity, can significantly affect flow. We have found that to maintain a coronary sinus pressure of 30 to 40 mm Hg, with the coronary sinus occluded, blood cardioplegic solution needs to be delivered at a rate of approximately 0.5 ml/gm of heart tissue per minute. The authors' finding of a coronary sinus pressure of 40 mm Hg with a flow rate of 100 ml/min suggests either an unusually high vascular resistance or very small experimental hearts. Finally, when one considers the relative mass differences between the left and right ventricles, is it possible that some right ventricular perfusion is occurring during these experiments but that its identification is below the sensitivity of electron-beam computed tomography? Despite our disagreement regarding right ventricular perfusion, this article contains two pieces of anatomic information that we have also found to be true. The first is the highly variable number of venovenous anastomoses between veins arising from the coronary sinus (most notably, the left anterior descending vein) and the posterior descending vein. We believe the quantity and quality of these anastomoses determine the amount of cardioplegic solution delivered to the posterior intraventricular septum and right ventricle when a transatrial coronary sinus cannula is being used, whether it is manually inflating or self-inflating cannula. Like the authors, we too have found these connections to be extremely variable and have noted significant differences in right ventricular microvascular flow from one heart to another. As such, the surgeon who uses warm continuous transatrial retrograde cardioplegia will have consequent variable right ventricular protection. This is particularly true if cardioplegic flow rates are below 0.5 ml/gm per minute. Indeed, our initial impetus for examining retrograde cardioplegic distribution was a poorly protected right ventricle after transatrial warm continuous retrograde blood cardioplegia. The second important finding in the article is the mean distance of just 1.7 ± 0.6 mm between the coronary sinus ostium and the posterior descending vein. Some clinicians have suggested that by properly positioning a manually inflating retroperfusion cannula, one can improve cardioplegic distribution to the intraventricular septum and right ventricle by direct perfusion of the posterior descending vein. In most cases, this is an anatomic impossibility. Reliable perfusion of the posterior descending vein can be achieved only by direct cannulation of the coronary sinus through an outer purse-string suture or by the right atrial isolation approach to retrograde cardioplegia delivery. 12/8/82505" @default.
- W2110396376 created "2016-06-24" @default.
- W2110396376 creator A5012141640 @default.
- W2110396376 creator A5069083851 @default.
- W2110396376 creator A5088124461 @default.
- W2110396376 date "1997-09-01" @default.
- W2110396376 modified "2023-09-29" @default.
- W2110396376 title "Angiographic and electron-beam computed tomography studies of retrograde cardioplegia via the coronary sinus" @default.
- W2110396376 cites W2018900886 @default.
- W2110396376 cites W2046012089 @default.
- W2110396376 cites W2059767385 @default.
- W2110396376 doi "https://doi.org/10.1016/s0022-5223(97)70220-4" @default.
- W2110396376 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/9305221" @default.
- W2110396376 hasPublicationYear "1997" @default.
- W2110396376 type Work @default.
- W2110396376 sameAs 2110396376 @default.
- W2110396376 citedByCount "0" @default.
- W2110396376 crossrefType "journal-article" @default.
- W2110396376 hasAuthorship W2110396376A5012141640 @default.
- W2110396376 hasAuthorship W2110396376A5069083851 @default.
- W2110396376 hasAuthorship W2110396376A5088124461 @default.
- W2110396376 hasBestOaLocation W21103963761 @default.
- W2110396376 hasConcept C126322002 @default.
- W2110396376 hasConcept C126838900 @default.
- W2110396376 hasConcept C146957229 @default.
- W2110396376 hasConcept C157369684 @default.
- W2110396376 hasConcept C164705383 @default.
- W2110396376 hasConcept C2776407911 @default.
- W2110396376 hasConcept C2778259205 @default.
- W2110396376 hasConcept C59822182 @default.
- W2110396376 hasConcept C71924100 @default.
- W2110396376 hasConcept C86803240 @default.
- W2110396376 hasConceptScore W2110396376C126322002 @default.
- W2110396376 hasConceptScore W2110396376C126838900 @default.
- W2110396376 hasConceptScore W2110396376C146957229 @default.
- W2110396376 hasConceptScore W2110396376C157369684 @default.
- W2110396376 hasConceptScore W2110396376C164705383 @default.
- W2110396376 hasConceptScore W2110396376C2776407911 @default.
- W2110396376 hasConceptScore W2110396376C2778259205 @default.
- W2110396376 hasConceptScore W2110396376C59822182 @default.
- W2110396376 hasConceptScore W2110396376C71924100 @default.
- W2110396376 hasConceptScore W2110396376C86803240 @default.
- W2110396376 hasIssue "3" @default.
- W2110396376 hasLocation W21103963761 @default.
- W2110396376 hasLocation W21103963762 @default.
- W2110396376 hasOpenAccess W2110396376 @default.
- W2110396376 hasPrimaryLocation W21103963761 @default.
- W2110396376 hasRelatedWork W1979958473 @default.
- W2110396376 hasRelatedWork W2001175574 @default.
- W2110396376 hasRelatedWork W2072105103 @default.
- W2110396376 hasRelatedWork W2076144941 @default.
- W2110396376 hasRelatedWork W2076786433 @default.
- W2110396376 hasRelatedWork W2092373775 @default.
- W2110396376 hasRelatedWork W2399834955 @default.
- W2110396376 hasRelatedWork W2803302214 @default.
- W2110396376 hasRelatedWork W2888669551 @default.
- W2110396376 hasRelatedWork W2924417201 @default.
- W2110396376 hasVolume "114" @default.
- W2110396376 isParatext "false" @default.
- W2110396376 isRetracted "false" @default.
- W2110396376 magId "2110396376" @default.
- W2110396376 workType "article" @default.