Matches in SemOpenAlex for { <https://semopenalex.org/work/W2145333548> ?p ?o ?g. }
Showing items 1 to 64 of
64
with 100 items per page.
- W2145333548 endingPage "166" @default.
- W2145333548 startingPage "164" @default.
- W2145333548 abstract "Monitoring of anaesthetic effects on the main target organ of anaesthesia, the brain, has evolved from a research tool to a clinical method and may help to adjust anaesthetic drugs to specific individual requirements (i.e. to avoid inadequate anaesthetic depth with the risk of awareness or excessively deep hypnosis). The term ‘anaesthetic depth’ is poorly defined and dates back to a period when general anaesthesia was induced by a single substance. A combination of effects and side effects were used to quantify ‘depth of anaesthesia’. Today, a combination of drugs are used to induce general anaesthesia, and several aspects of anaesthetic effects are induced by specific drugs. Consequently, present definitions try to follow this combinatory approach. Different ‘components’ of anaesthesia seem to follow the different types of drugs administered to induce general anaesthesia. This results in the core problem: the difficulty to find an all-embracing definition of anaesthetic depth–which would be the basis to develop suitable assessment methods. Thus, the present definition must remain very vague: according to the ASA task force, depth of anaesthesia or depth of hypnosis refers to a continuum of progressive central nervous system depression and decreased responsiveness to stimulation.1American Society of Anesthesiologists Task Force on Intraoperative Awareness. Practice advisory for intraoperative awareness and brain function monitoring: a report by the american society of anesthesiologists task force on intraoperative awareness.Anesthesiology. 2006; 104: 847-864Crossref PubMed Scopus (269) Google Scholar The assessment of clinical signs as responses to stimulation has been established in several clinical sedation scores. This definition may not entirely follow the present concept of general anaesthesia. Responsiveness to stimulation may reflect the ‘hypnotic component’, but may also be influenced by the ‘antinociceptive component’, because analgesia and antinociception may also reduce responses to painful stimuli. It remains unclear whether a separation in these different components, as driven by classes of drugs is clearly possible. In addition, many drug effects seem to follow an ‘all-or-none’ principle, or a very steep drug response curve. Consequently, the concept of ‘depth’ has been questioned, because a human may not be a submarine during anaesthesia.2Sleigh JW Depth of anesthesia: perhaps the patient isn't a submarine.Anesthesiology. 2011; 115: 1149-1150Crossref PubMed Scopus (18) Google Scholar Still, an increase of anaesthetic drugs induces graded changes of the clinical status of a patient. The use of clinical signs may not be reliable in measuring the hypnotic component of anaesthesia.3Domino KB Posner KL Caplan RA Cheney FW Awareness during anesthesia: a closed claims analysis.Anesthesiology. 1999; 90: 1053-1061Crossref PubMed Scopus (286) Google Scholar The key features of EEG changes in response to different doses of anaesthetic agents and clinical state responses were established and suggest the clinical feasibility of depth of anaesthesia (DOA) monitors: these are devices that record or process brain electrical activity, usually from frontal EEG, as a surrogate for the drug effects on the entire central nervous system (CNS). Several parameters are calculated from the EEG, and these parameters are combined and mathematically converted into a continuous measure typically scaled from 0 to 100. Clinical measures of consciousness represent an important component in the development process of an EEG based index. As far as it is known, the majority of commercially available EEG based monitors were validated with different clinical scales during their development process (e.g. the manufacturers of bispectral index (BIS), cerebral state index and patient state index monitor referred to the modified OAA/S score, to define which EEG based subparameters, or a combination of them correlated best with the clinical state). In contrast to other indices, entropy based EEG monitoring calculates entropy of the EEG from awake to deep anaesthesia (i.e. the same parameter is calculated over a wide range, only the time window of the EEG increases with increasing drug effects). The time-frequency balanced spectral entropy is calculated by the Datex-Ohmeda Entropy™ Module. With this approach, clinical signs are not necessarily required for the combination of sub-parameters, but for the scaling of the index values. Aside from the underlying algorithm – each index was developed on the basis of a separate training data set with different patients or volunteers and different anaesthetic regimens. As a consequence, the performance of a monitor can only be as good as the corresponding database. Furthermore, the ability of an index value to recognize the hypnotic state can only be as reliable as the underlying method to classify the clinical state during development process. Today, different EEG-based monitors and indices are on the market. Mostly, the underlying algorithms remain proprietary. There is neither a possibility to thoroughly comprehend the performance of one DOA index nor to explain outliers - both would be substantial for a valid interpretation of EEG analysis and for the reasonable transfer of these findings to clinical context. Furthermore, comparability of different DOA monitors is limited. There is no reason why different DOA index values should show similar trajectories across time, because they are based on different processing times,4Pilge S Zanner R Schneider G Blum J Kreuzer M Kochs EF Time delay of index calculation: analysis of cerebral state, bispectral, and narcotrend indices.Anesthesiology. 2006; 104: 488-494Crossref PubMed Scopus (148) Google Scholar, 5Zanner R Pilge S Kochs EF Kreuzer M Schneider G Time delay of electroencephalogram index calculation: analysis of cerebral state, bispectral, and Narcotrend indices using perioperatively recorded electroencephalographic signals.Br J Anaesth. 2009; 103: 394-399Abstract Full Text Full Text PDF PubMed Scopus (85) Google Scholar, 6Kreuzer M Zanner R Pilge S Paprotny S Kochs EF Schneider G Time delay of monitors of the hypnotic component of anesthesia: analysis of state entropy and index of consciousness.Anesth Analg. 2012; 115: 315-319Crossref PubMed Scopus (30) Google Scholar different artifact rejection algorithms and different calculation algorithms for generating an index. But how to compare apples and oranges? One possible approach for the comparison of different DOA monitors may be the analysis of the unprocessed EEG sequences that underlie index computation. Information about the underlying raw (time domain) EEG signals may allow for the evaluation of the potential influence of distinct EEG findings/artifacts on index calculation: index calculation may be influenced because of physiological EEG pattern (e.g. beta or delta arousal), pathophysiological features (e.g. epileptiform pattern, electrooculogram, electromyogram (EMG)), or technical artifacts (e.g. from weak electrode contact or cautery). Such an approach may contribute to the elucidation of the mechanistic causes of discrepancies/outliers between different index values: if EEG is influenced by ‘pathology’, indices may be misleading. If two indices disagree, one of them or both can be ‘wrong’ because of these reasons. So far, only one comparative study has used the information of unprocessed EEG for such a comparison.7Pilge S Kreuzer M Karatchiviev V Kochs EF Malcharek M Schneider G Differences between state entropy and bispectral index during analysis of identical electroencephalogram signals: A randomised comparison of two anaesthetic techniques.Eur J Anaesthesiol. 2015; 32: 354-365Crossref PubMed Scopus (18) Google Scholar In an offline reanalysis of EEG data from two anaesthetic regimens (propofol and sevoflurane anaesthesia), EEG was inspected for potential causes of erroneous index calculation of BIS and state entropy (SE) during analysis of identical EEG signals. With information about the level of consciousness, EEG sequences were identified which produced index values that were in conflict with clinical examination. These sequences were analysed with respect to frequency characteristics (frequency bands/SEF95), and visually inspected for physiological EEG pattern and pathophysiological features. High frequency signals and eye blinks were present in the majority of all EEG sequences and may in particular account for index values that falsely indicate consciousness. Compared with BIS, SE more often showed false classifications of the clinical state at transitions between consciousness and unconsciousness. There was a trend toward higher incidence of high frequency signals and eye blinks during sevoflurane compared with propofol anaesthesia. Unfortunately, it remains impossible to exclusively evaluate the impact of artifacts on the EEG signal or to ascertain if these are causal for erroneous index calculation: the exact algorithms of index calculation have not been revealed in detail by the manufacturers. Further, it is unknown how monitor configuration settings of BIS and SE (e.g. filter settings) influence signal processing. In addition, most artifacts are not characterized by a stereotype response. As a result of these findings, a uniform explanation for failure of DOA monitors seems unlikely. In the present issue of the British Journal of Anaesthesia, Aho and colleagues present a prospective study in 65 patients during general anaesthesia with sevoflurane.8Aho AJ Kamata K Jäntti V et al.Comparison of Bispectral Index and Entropy values with electroencephalogram during surgical anaesthesia with sevoflurane.Br J Anaesth. 2015; 115: 258-266Abstract Full Text Full Text PDF PubMed Scopus (21) Google Scholar The authors analysed the raw EEG signals underlying conflicting BIS and SE values during surgical anaesthesia in order to identify EEG characteristics that cause discrepancies between both index values. The study endpoint - disagreement between BIS and SE values - was defined as a difference ≥10 index points for ≥60 s. The underlying raw EEG signal was visually inspected and analysed in time and frequency domain. The endpoint was observed in 11% of all BIS and SE index pairs. The authors concluded that the following EEG findings can cause index discrepancies: during burst suppression and alpha or beta activity, SE values were higher than BIS. A delta-theta dominance resulted in a higher BIS values. Furthermore, EMG and electro-cautery accounted for differences between index values. In the present analysis, only EEG sequences during surgical anaesthesia were included. These may not be as artifact-contaminated as EEG sequences during lighter levels of anaesthesia, in particular at the transitions between unconsciousness and unconsciousness. The study of Aho and colleagues offers interesting insights in EEG analysis, but important study limitations have to be discussed. Despite the opportunity of a prospective study design, their present approach misses the target: their study design lacks of a golden standard for the comparison of EEG based indices and the used endpoint to define index differences may be considered as clinically irrelevant. As a result of index computation, the recommended ranges of processed EEG based index values for the respective levels of hypnosis reflect probability functions rather than absolute, clinical or pharmacological classifications. The authors defined discrepancies between BIS and SE whenever the index values differed ≥10 index points. There is no evidence that index values of different EEG based monitors should agree. They rather may run in a continuous, but not in a linear manner–as a result of manifold and partially unknown reasons (e.g. different calculation algorithms or underlying training data sets). Therefore, one must expect differences between index values of different monitors, because an index value does not quantify a physiological parameter, but a constructed probability function based on a clinical assessment of a poorly defined endpoint. Furthermore, there is little reason to believe that different index values obtained from different persons during ‘comparable levels of consciousness’ would be clinically meaningful. As an example: is an index value of 100 before induction of general anaesthesia different to an index value of 90? Index differences ≥10 units do not necessarily imply that both monitors display different levels of anaesthesia and may have no clinical relevance. Thus, the endpoint may not be appropriate for a comparison of different depth of anaesthesia monitors. The study design of Aho and colleagues lacks a golden standard for the level of hypnosis (i.e. an assessment of whether an index value indicates the correct level of anaesthesia). Thus, the study misses the opportunity to answer the key questions of mechanistic causes of index discrepancies. These questions may be: what was different about the raw EEG of the patients that were unresponsive (responsive) but had a high (low) BIS/SE values indicating consciousness (unconsciousness)? What was different about the EEG of the patients that had a high BIS but a low SE or vice versa? As long as anaesthesia indices are based on probabilistic approaches, the golden standard remains the clinical assessment of the level of consciousness. During surgical anaesthesia, the determination of a clinical endpoint is difficult. The classification of EEG stages may represent an alternative solution. The investigation of causal sources (e.g. specific EEG pattern or artifacts) that may mislead one or both monitors to indicate a level of anaesthesia, that does not agree with the golden standard (clinical or EEG assessment), requires the analysis of all EEG sequences. Further, it should be described how often the respective EEG pattern/artifact is identified in EEG sequences underlying index values, that agree/disagree with the golden standard. It is important that current anaesthesia indices reflect a probability function of a clinical state rather than a physiological parameter. As these indices of the hypnotic component of anaesthesia may not follow a common definition of this hypnotic component, and may not be scaled to the same dose-response curve, index values are not comparable simply by a comparison of numbers. Therefore, not everything that calculates a dimensionless number from 0 to 100 is comparable with each other. The EEG is more than just a number, and blind trust in a calculated number should be avoided, because it may result in a comparison of apples and oranges." @default.
- W2145333548 created "2016-06-24" @default.
- W2145333548 creator A5000445992 @default.
- W2145333548 creator A5031160333 @default.
- W2145333548 date "2015-08-01" @default.
- W2145333548 modified "2023-09-29" @default.
- W2145333548 title "BIS and state entropy of the EEG - comparing apples and oranges" @default.
- W2145333548 cites W1913513330 @default.
- W2145333548 cites W2033583993 @default.
- W2145333548 cites W2070010649 @default.
- W2145333548 cites W2093865019 @default.
- W2145333548 cites W2139574882 @default.
- W2145333548 cites W2197606091 @default.
- W2145333548 cites W2319855389 @default.
- W2145333548 doi "https://doi.org/10.1093/bja/aev145" @default.
- W2145333548 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/26025240" @default.
- W2145333548 hasPublicationYear "2015" @default.
- W2145333548 type Work @default.
- W2145333548 sameAs 2145333548 @default.
- W2145333548 citedByCount "8" @default.
- W2145333548 countsByYear W21453335482015 @default.
- W2145333548 countsByYear W21453335482016 @default.
- W2145333548 countsByYear W21453335482017 @default.
- W2145333548 countsByYear W21453335482018 @default.
- W2145333548 countsByYear W21453335482021 @default.
- W2145333548 countsByYear W21453335482022 @default.
- W2145333548 crossrefType "journal-article" @default.
- W2145333548 hasAuthorship W2145333548A5000445992 @default.
- W2145333548 hasAuthorship W2145333548A5031160333 @default.
- W2145333548 hasBestOaLocation W21453335481 @default.
- W2145333548 hasConcept C105795698 @default.
- W2145333548 hasConcept C149782125 @default.
- W2145333548 hasConcept C15744967 @default.
- W2145333548 hasConcept C169760540 @default.
- W2145333548 hasConcept C33923547 @default.
- W2145333548 hasConcept C522805319 @default.
- W2145333548 hasConceptScore W2145333548C105795698 @default.
- W2145333548 hasConceptScore W2145333548C149782125 @default.
- W2145333548 hasConceptScore W2145333548C15744967 @default.
- W2145333548 hasConceptScore W2145333548C169760540 @default.
- W2145333548 hasConceptScore W2145333548C33923547 @default.
- W2145333548 hasConceptScore W2145333548C522805319 @default.
- W2145333548 hasIssue "2" @default.
- W2145333548 hasLocation W21453335481 @default.
- W2145333548 hasLocation W21453335482 @default.
- W2145333548 hasOpenAccess W2145333548 @default.
- W2145333548 hasPrimaryLocation W21453335481 @default.
- W2145333548 hasRelatedWork W1979784219 @default.
- W2145333548 hasRelatedWork W1980905932 @default.
- W2145333548 hasRelatedWork W2049502031 @default.
- W2145333548 hasRelatedWork W2066157660 @default.
- W2145333548 hasRelatedWork W2083542484 @default.
- W2145333548 hasRelatedWork W2119158312 @default.
- W2145333548 hasRelatedWork W2330407128 @default.
- W2145333548 hasRelatedWork W2552050053 @default.
- W2145333548 hasRelatedWork W2969635709 @default.
- W2145333548 hasRelatedWork W4234996786 @default.
- W2145333548 hasVolume "115" @default.
- W2145333548 isParatext "false" @default.
- W2145333548 isRetracted "false" @default.
- W2145333548 magId "2145333548" @default.
- W2145333548 workType "article" @default.