Matches in SemOpenAlex for { <https://semopenalex.org/work/W2146993893> ?p ?o ?g. }
Showing items 1 to 94 of
94
with 100 items per page.
- W2146993893 endingPage "352" @default.
- W2146993893 startingPage "349" @default.
- W2146993893 abstract "BioanalysisVol. 3, No. 4 EditorialFree AccessPhospholipid-based matrix effects in LC–MS bioanalysisXinghua Guo & Ernst LankmayrXinghua Guo† Author for correspondenceInstitute of Analytical Chemistry and Food Chemistry, Graz University of Technology, Stremayrgasse 9, 8010 Graz, Austria. Search for more papers by this authorEmail the corresponding author at x.guo@tugraz.at & Ernst LankmayrInstitute of Analytical Chemistry and Food Chemistry, Graz University of TechnologySearch for more papers by this authorPublished Online:21 Feb 2011https://doi.org/10.4155/bio.10.213AboutSectionsPDF/EPUB ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareShare onFacebookTwitterLinkedInReddit Keywords: biological matricesLC–MS bioanalysismatrix effectphospholipidssample preparationLC–MS/MS is now the method of choice for a very broad range of applications in quantitative bioanalysis, owing to its inherent high selectivity and sensitivity [1,2]. However, at the same time, matrix effects are often encountered as an obstacle for trace bioanalysis [3,4]. Matrix effects refers to the enhancement or suppression of the analyte response caused by co-eluting endogenous matrix constituents either through influencing ionization or simply acting as isobaric interferences as initially recognized by Kebarle et al. in the early 1990s [5]. For instance, its impact on the accuracy, precision and robustness of analytical methods is of growing concern in clinical and pharmaceutical research dealing with a biological matrix, such as plasma, urine, blood, bile, feces, tissues, cell-incubation media and pharmaceutical formulations. Matrix effects may result from lipids (especially phospholipids [PLs]), proteins, salts, drugs and metabolites, other endogenous compounds, buffers, ion-pairing agents, dosing-formulation agents and exogenous contamination, to name just a few. Although the matrix effect has been drawing more and more attention from researchers to discuss or to evaluate in method development and validation, only in some published methods is an actual step included to minimize this interference. For bioanalysis, under certain investigated conditions, various approaches reported in the literature have been proven to be effective at removing interferences from PLs or for a general purpose [3,6]. However, because of the huge diversity of the biological matrices and especially their possible accumulation on the separation column, the interferences are not always reproducible and predictable. Currently, there is still no universal solution to this problem [3]. The matrix effect caused by PL is somehow underestimated when we look deeply into the sources of lipids and commonly applied compromising sample-preparation methods in practice. To reveal this, one should have a close investigation of these notorious PL species and, especially, their chromatographic behavior in general, which results in the persistent matrix effect.Broad diversity of PLAs the main constituent of cell membranes, PLs are the main source of matrix effects in LC–MS bioanalysis. They can be found in all biological matrices in significant concentrations [7]. The matrix effect caused by PLs is one of the greatest challenges in method development and validation. The difficulty of completely eliminating their severe interference comes not only from their high concentrations and overall presence, but also, more importantly, from their diversity with regard to classes, subclasses, polarities and molecular weights. Reportedly, as active biomolecules participating in biological activities, PLs can range from neutral to polar and ionic molecules, predominantly with the skeletons of nonpolar fatty chains attached to a polar phosphate. In addition, lysophospholipids (with only one fatty chain), free fatty acids and numerous metabolites and analogues have also been identified [8]. For instance, with the improvement in identification and detector sensitivities, the remarkable diversity of over 500 distinct lipid molecular species from six major categories [9,10], in pooled human plasma, has been reported in recent studies [11]. Due to their unique structural features, most lipid molecules behave like a surfactant, which makes the clean-up efforts less effective. As a result of this diversity, and their intrinsic structural characteristics, the matrix effect caused by PLs actually penetrates into every corner of trace bioanalysis, from nonpolar to polar analytes and both small- and large-molecule quantification.Effectiveness of current strategies to reduce or eliminate matrix effectsSeveral strategies have been dominating with regards to the reduction of matrix effects in general [3,6]. Through proper calibration, such as the following, matrix effects can be partially compensated: ▪ Matrix-matched external calibration;▪ Proper internal standardization;▪ Eco-peak technique (injections of a sample and reference standard with a short interval [12]).The eco-peak technique is less frequently used. However, even the first two approaches can only have limited applications due to the scarcity of an appropriate perfectly matrix-matched sample as the blank or the stable isotope-labeled analytes. The application of analyte analogues as internal standards can also be problematic because the matrix effect is actually dependent on the retention time. A very recent study has shown that, even with stable isotope-labeled standards, ion enhancement of approximately 500% for omeprazole in urine was observed in one lot, but not in the others, which was confirmed to be resulting from a combination of non-uniform matrix and nonlinear LC–MS detector response [13]. In addition, it is also reported that, by modifying the MS ionization and detection, it is possible to reduce or prevent the matrix effect, for instance, by switching the ionization mode or the source design [3]. However, the presence of matrix components in samples is still a potential risk for the subsequent LC–MS analysis because of the possible unexpected effect, or accumulation, during chromatographic separation. Accordingly, the best cure to this problem is to remove the troublesome matrix components before injection into the instrument. The techniques used to separate the components causing matrix effects include on- and off-line clean-ups in sample preparation (e.g., protein precipitation, liquid–liquid extraction [LLE], SPE [14], turbulent-flow chromatography with valve switching [15] and ultrafiltration) and/or, otherwise, improvement in chromatographic separation in LC–MS analysis [3,16–18].Chambers et al. have systematicall investigated various sample-preparation strategies for reducing phospholipid matrix effects in LC–MS/MS bioanalysis [14]. They concluded that, although LLE could provide clean final extracts, the analyte recovery, particularly for polar analytes, was very low. Protein precipitation was effective at reducing the matrix effect caused by proteins in other studies, but turned out to be the least effective for PLs. The most popular reverse-phase and pure-cation exchange SPE methods also resulted in cleaner extracts and reduced matrix effects compared with protein precipitation. The cleanest extracts, however, were produced with polymeric mixed-mode SPE with both reverse-phase and ion-exchange retention mechanisms, leading to significant reduction in matrix effects [14]. It was also reported that a combination of polymeric mixed-mode SPE, the appropriate mobile-phase pH and UPLC technology shows significant advantages for reducing matrix effects resulting from plasma constitutes [14]. However, in practice, the best approach to minimize the matrix effect is not always feasible to include in the sample preparation. In addition, another recent study concluded that no single extraction procedure was efficient in removing all of the various lipid components when most PL classes and neutral lipids in blood plasma were considered [19]. This further indicates the persistent interference from PLs.Elution behavior of PLs in LCAlthough it seems less laborious and costly, manipulating chromatographic separation in LC–MS is often the least effective among the approaches to reduce matrix effects from PLs. The reason behind this phenomenon, which is also the cause of matrix interference, is their contradictory chromatographic elution behavior. Since the beginning of PL analysis, only simple LLE with chloroform/methanol [20,21] results in an overwhelmingly united chromatographic behavior for almost all PL, as it provides the most efficient extraction from biological samples. Unfortunately, LLE implementation is not always possible owing to the simultaneous loss of analytes. In other techniques, such as column chromatography, SPE and HPLC involving column chemistry and selectivity, not only is a separation of classes and subclasses difficult but sometimes it also requires extraordinary mobile-phase compositions to elute them from the columns, owing to the wide polarity diversity of PLs. For instance, with a normal-phase column based either on silica gels or those modified with diol, cyanopropyl and aminopropyl, the polar and acidic phosphatidylserines and phosphatidylinositols will not be recovered well because of the strong adsorption and tailing on SPE or HPLC columns, although it provides a better separation of other classes [22]. PLs co-eluting with analytes will result in instant matrix effect, and those retained on the column will remain and cause problems for the subsequent injection. The latter effect may be partially prevented if this is followed by a regenerating elution step using a mobile phase of a higher ionic strength. On the other hand, with a reverse-phase C18 column, the abundant phosphatidylcholines (PCs) with the polar head groups of strong ionic characteristics are eluted later with high organic mobile-phase contents. The problem is also caused by their slow elution, consequently resulting in broad peaks with tailing. In addition, the earlier eluted polar lysophospholipids (also relatively abundant, together with other lysophospholipids) threaten the earlier eluted analytes [17]. Significant variations of the retention times of PLs, PCs and lysophospholipids under different hydrophilic interaction LC conditions have also been reported [23]. As a result, multidimensional LC approaches have also been investigated and proposed for PL analysis [24]. Owing to this, the manipulation of chromatographic separation to avoid matrix effects due to co-elution will not always work. A blank injection after the sample, using isopropyl alcohol to regenerate columns, can significantly reduce the interference; however, it is not implemented in most studies for apparent reasons of costs and analysis time [17,18].The LC–MS applications most affected by matrix effects include multiresidue bioanalysis, high-throughput application, screening and those with automated sample preparation for pesticides and pollution monitoring, drugs and metabolomics and systems biology investigations. Matrix effects are not only analyte dependent, but also batch matrix dependent [25]. Although a complete elimination can be difficult, reduction is always possible if a careful optimization in method development is involved [26]. For LC–MS trace analysis of biological samples, every possible effect matters and any improvement counts.Financial & competing interests disclosureThe authors have no relevant affiliations or financial involvement with any organization or entity with a financial interest in or financial conflict with the subject matter or materials discussed in the manuscript. This includes employment, consultancies, honoraria, stock ownership or options, expert testimony, grants or patents received or pending, or royalties.No writing assistance was utilized in the production of this manuscript.Bibliography1 Jemal M, Xia YQ. LC–MS development strategies for quantitative bioanalysis. Curr. Drug Metab.7,491–502 (2006).Crossref, Medline, CAS, Google Scholar2 Hofgartner G, Bourgogne E. Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry. Mass Spectrom. Rev.22,195–214 (2003).Crossref, Medline, Google Scholar3 Trufelli H, Palma P, Famiglini G, Cappiello A. An overview of matrix effects in liquid chromatography–mass spectrometry. Mass Spectrom. Rev. DOI: 10.1002/mas.20298 (2010) (Epub ahead of print).Medline, Google Scholar4 Chiu ML, Lawi W, Snyder ST, Wong PK, Liao JC, Gau V. Matrix effects – a challenge toward automation of molecular analysis. J. Assoc. Lab. Autom.15,233–242 (2010).Crossref, CAS, Google Scholar5 Kebarle P, Tang L. From ions in solution to ions in the gas phase – the mechanism of electrospray mass spectrometry. Anal. Chem.65,972A–986A (1993).Crossref, CAS, Google Scholar6 Bennett P, Meng M, Čápka V. Managing phospholipids-based matrix effects in bioanalysis. Proceedings of: The 17th International Mass Spectrometry Conference (IMSC), Prague, Czech Republic, 1 September 2006.Google Scholar7 Bradamante S, Barchiesi E, Barenghi L, Zoppi F. An alternative expeditious analysis of phospholipid composition in human blood plasma by 31P NMR spectroscopy. Anal. Biochem.185,299–303 (1990).Crossref, Medline, CAS, Google Scholar8 Moumtzi A, Trenker M, Flicker K, Zenzmaier E, Saf R, Hermetter A. Import and fate of fluorescent analogs of oxidized phospholipids in vascular smooth muscle cells. J. Lipid Res.48,565–582 (2007).Crossref, Medline, CAS, Google Scholar9 Taguchi R, Hayakawa J, Takeuchi Y, Ishida M. Two-dimensional analysis of phospholipids by capillary liquid chromatography–electrospray ionization mass spectrometry. J. Mass Spectrom.35,953–966 (2000).Crossref, Medline, CAS, Google Scholar10 Han X, Gross RW. Shotgun lipidomics: electrospray ionization mass spectrometric analysis and quantitation of cellular lipidomes directly from crude extracts of biological samples. Mass Spectrom. Rev.24,367–412 (2005).Crossref, Medline, CAS, Google Scholar11 Quehenberger O, Armando AM, Brown AH et al. Lipidomics reveals a remarkable diversity of lipids in human plasma. J. Lipid Res.51,3299–3305 (2010).Crossref, Medline, CAS, Google Scholar12 Alder L, Lüderitz S, Lindtner K, Stan HJ. The ECHO technique – the more effective way of data evaluation in liquid chromatography–tandem mass spectrometry analysis. J. Chromatogr. A1058,67–79 (2004).Crossref, Medline, CAS, Google Scholar13 Liu G, Ji QC, Arnold ME. Identifying, evaluating and controlling bioanalytical risks resulting from nonuniform matrix ion suppression/enhancement and nonlinear liquid chromatography–mass spectrometry assay response. Anal. Chem.82,9671–9677 (2010).Crossref, Medline, CAS, Google Scholar14 Chambers E, Wagrowski-Diehl DM, Lu Z, Mazzeoe JR. Systematic and comprehensive strategies for reducing matrix effects in LC–MS/MS analyses. J. Chromatogr. B Analyt. Technol. Biomed. Life Sci.852,22–34 (2007).Crossref, Medline, CAS, Google Scholar15 Du L, White RL. Reducing glycerophosphocholine lipid matrix interference effects in biological fluid asays by using high-turbulence liquid chromatography. Rapid Commun. Mass Spectrom.22,3362–3370 (2008).Crossref, Medline, CAS, Google Scholar16 Bhatt J, Subbaiah G, Singh S. Liquid chromatography–tandem mass spectrometry method for simultaneous determination of risperidone and its active metabolite 9-hydroxyrisperidone in human plasma. Rapid Commun. Mass Spectrom.20,2109–2114 (2005).Crossref, Google Scholar17 Xia Y, Jemal M. Phospholipids in liquid chromatography–mass spectrometry bioanalysis: comparison of three tandem mass spectrometric techniques for monitoring plasma phospholipids, the effect of mobile-phase composition on phospholipids elution and the association of phospholipids with matrix effects. Rapid Commun. Mass Spectrom.23,2125–2138 (2009).Crossref, Medline, CAS, Google Scholar18 Little JL, Wempe MF, Buchanan CM. Liquid chromatography–mass spectrometry/mass spectrometry method development for drug metabolism studies: examining lipid matrix ionization effects in plasma. J. Chromatogr. B Analyt. Technol. Biomed. Life Sci.833,219–230 (2006).Crossref, Medline, CAS, Google Scholar19 Ismaiel OA, Zhang T, Jenkins RG, Karnes HT. Investigation of endogeneous blood plasma phospholipids, cholesterol and glycerides that contribute to matrix effects in bioanalysis by liquid chromatography–mass spectrometry. J. Chromatogr. B Analyt. Technol. Biomed. Life Sci.878,3303–3316 (2010).Crossref, Medline, CAS, Google Scholar20 Folch F, Lees M, Sloane Stanley GH. A simple method for the isolation of and purification of total lipids from animal tissues. J. Biol. Chem.226,497–509 (1957).Crossref, Medline, CAS, Google Scholar21 Bligh EG, Dyer WJ. A rapid method of total lipid extraction and purification. Can. J. Biochem. Physiol.37,911–917 (1959).Crossref, Medline, CAS, Google Scholar22 Suzuki E, Sano A, Kuriki T, Miki T. Improved separation and determination of phospholipids in animal tissue employing solid-phase extraction. Biol. Pharm. Bull.20,299–303 (1997).Crossref, Medline, CAS, Google Scholar23 Mess JN, Côté C, Bergeron A, Furtado M, Garofolo F. Selection of HILIC columns to handle matrix effect due to phospholipids. Bioanalysis1(1),57–62 (2009).Link, CAS, Google Scholar24 Guo X, Lankmayr E. Multidimensional approaches in LC and MS for phospholipid bioanalysis. Bioanalysis2(6),1109–1123 (2010).Link, CAS, Google Scholar25 Stahnke H, Reemtsma T, Alder L. Compensation of matrix effects by postcolumn infusion of a monitor substance in multiresidue analysis with LC–MS/MS. Anal. Chem.81,2185–2192 (2009).Crossref, Medline, CAS, Google Scholar26 Côté C, Bergeron A, Mess JN, Furtado M, Garofolo F. Matrix effect elimination during LC–MS/MS bioanalytical method development. Bioanalysis1(7),1243–1257 (2009).Link, CAS, Google ScholarFiguresReferencesRelatedDetailsCited ByDevelopment of polyanion-metal ion solution systems to overcome phospholipids-related matrix effects in LC-MS/MS-based bioanalysisAnalytica Chimica Acta, Vol. 1250Enhanced chromatographic efficiency obtained with vacuum jacketed columns facilitates the rapid UHPLC/MS/MS-based analysis of fasiglifam in rat plasmaTalanta, Vol. 254A validated UHPLC-MS/MS method for simultaneous quantification of some repurposed COVID-19 drugs in rat plasma: Application to a pharmacokinetic studyMicrochemical Journal, Vol. 178A Rapid and Simple UHPLC-MS/MS Method for Quantification of Plasma Globotriaosylsphingosine (lyso-Gb3)3 December 2021 | Molecules, Vol. 26, No. 23Comprehensive Identification of Glycosphingolipids in Human Plasma Using Hydrophilic Interaction Liquid Chromatography—Electrospray Ionization Mass Spectrometry26 February 2021 | Metabolites, Vol. 11, No. 3Recent advances in the mass spectrometric analysis of glycosphingolipidome – A reviewAnalytica Chimica Acta, Vol. 1132Simultaneous Measurement of Tricarboxylic Acid Cycle Intermediates in Different Biological Matrices Using Liquid Chromatography–Tandem Mass Spectrometry; Quantitation and Comparison of TCA Cycle Intermediates in Human Serum, Plasma, Kasumi-1 Cell and Murine Liver Tissue12 March 2020 | Metabolites, Vol. 10, No. 3Effective quantification of 11 tyrosine kinase inhibitors and caffeine in human plasma by validated LC-MS/MS method with potent phospholipids clean-up procedure. Application to therapeutic drug monitoringTalanta, Vol. 208Simultaneous determination of six antipsychotics, two of their metabolites and caffeine in human plasma by LC-MS/MS using a phospholipid-removal microelution-solid phase extraction method for sample preparationTalanta, Vol. 198Ultrahigh-Performance Liquid Chromatography Tandem Mass Spectrometry with Electrospray Ionization Quantification of Tryptophan Metabolites and Markers of Gut Health in Serum and Plasma—Application to Clinical and Epidemiology Cohorts8 March 2019 | Analytical Chemistry, Vol. 91, No. 8Issues of interferences in therapeutic drug monitoringEvaluation of two-step liquid-liquid extraction protocol for untargeted metabolic profiling of serum samples to achieve broader metabolome coverage by UPLC-Q-TOF-MSAnalytica Chimica Acta, Vol. 1035Method selectivity evaluation using the co-feature ratio in LC/MS metabolomics: Comparison of HILIC stationary phase performance for the analysis of plasma, urine and cell extractsJournal of Chromatography A, Vol. 1568Suitable simple and fast methods for selective isolation of phospholipids as a tool for their analysis30 March 2018 | ELECTROPHORESIS, Vol. 39, No. 15Metabolomic approaches for phospholipid analysis: advances and challengesRaúl González-Domínguez10 July 2018 | Bioanalysis, Vol. 10, No. 14Dried blood spots and parallel artificial liquid membrane extraction–A simple combination of microsampling and microextractionAnalytica Chimica Acta, Vol. 1009Sample Preparation for Mass Spectrometry ApplicationsDetermination of steroid hormones in fish tissues by microwave-assisted extraction coupled to ultra-high performance liquid chromatography tandem mass spectrometryFood Chemistry, Vol. 237Efficient discrimination and removal of phospholipids during electromembrane extraction from human plasma samplesLinda Vårdal, Astrid Gjelstad, Chuixiu Huang, Elisabeth Leere Øiestad & Stig Pedersen-Bjergaard16 May 2017 | Bioanalysis, Vol. 9, No. 8The co-feature ratio, a novel method for the measurement of chromatographic and signal selectivity in LC-MS-based metabolomicsAnalytica Chimica Acta, Vol. 956Comparison of sample preparation strategies for target analysis of total thyroid hormones levels in serum by liquid chromatography-quadrupole time-of-flight-mass spectrometryTalanta, Vol. 164Sample preparation techniques for mass spectrometry in the clinical laboratoryStable-Isotope Dilution HPLC–Electrospray Ionization Tandem Mass Spectrometry Method for Quantifying Hydroxyurea in Dried Blood Samples1 December 2016 | Clinical Chemistry, Vol. 62, No. 12Parallel artificial liquid membrane extraction as an efficient tool for removal of phospholipids from human plasmaJournal of Pharmaceutical and Biomedical Analysis, Vol. 129Application of liquid chromatography combined with mass spectrometry or tandem mass spectrometry for therapeutic drug monitoring of immunosuppressantsMatrix Effects in Liquid Chromatography-Electrospray Ionization-Mass Spectrometry1 May 2015Reverse-Polynomial Dilution Calibration Methodology Extends Lower Limit of Quantification and Reduces Relative Residual Error in Targeted Peptide Measurements in Blood PlasmaMolecular & Cellular Proteomics, Vol. 14, No. 2Simultaneous determination of imperatorin and its metabolite xanthotoxol in rat plasma by using HPLC–ESI-MS coupled with hollow fiber liquid phase microextractionJournal of Chromatography B, Vol. 945-946System Suitability in LC-MS Bioanalysis30 August 2013An improved SPE method for fractionation and identification of phospholipids24 January 2013 | Journal of Separation Science, Vol. 36, No. 4Issues of Interferences in Therapeutic Drug MonitoringDried Blood Spot Sampling with LC-MS Analysis for Routine Therapeutic Caffeine Monitoring in NeonatesISRN Chromatography, Vol. 2012The importance of experimental design and QC samples in large-scale and MS-driven untargeted metabolomic studies of humansWarwick B Dunn, Ian D Wilson, Andrew W Nicholls & David Broadhurst9 October 2012 | Bioanalysis, Vol. 4, No. 18Utilization of hydrophilic-interaction LC to minimize matrix effects caused by phospholipidsBeijing Tan, Andre Negahban, Thomas McDonald, Yizhong Zhang & Christopher Holliman4 September 2012 | Bioanalysis, Vol. 4, No. 16Implication of free cholesterol in LC–MS response enhancementRobert MacNeill, Amy Farside, Vishva Acharya, Ryan Stromeyer, Bryan Urbanowicz & Marc Moussallie1 June 2012 | Bioanalysis, Vol. 4, No. 10Investigation of microbore UPLC and nontraditional mobile phase compositions for bioanalytical LC–MS/MSPaul D Rainville, Jennifer L Simeone, Sean M McCarthy, Norman W Smith, David Cowan & Robert S Plumb21 June 2012 | Bioanalysis, Vol. 4, No. 11Perspectives on addressing ionization matrix effects in LC–MS bioanalysisZhenmin Liang1 June 2012 | Bioanalysis, Vol. 4, No. 10Comparison of extraction procedures for assessment of matrix effect for selective and reliable determination of atazanavir in human plasma by LC–ESI-MS/MSJournal of Chromatography B, Vol. 885-886Development of methods to monitor ionization modification from dosing vehicles and phospholipids in study samplesMin Chang, Yongchao Li, Reginald Angeles, Samina Khan, Lian Chen, Julia Kaplan & Liyu Yang9 August 2011 | Bioanalysis, Vol. 3, No. 15 Vol. 3, No. 4 Follow us on social media for the latest updates Metrics History Published online 21 February 2011 Published in print February 2011 Information© Future Science LtdKeywordsbiological matricesLC–MS bioanalysismatrix effectphospholipidssample preparationFinancial & competing interests disclosureThe authors have no relevant affiliations or financial involvement with any organization or entity with a financial interest in or financial conflict with the subject matter or materials discussed in the manuscript. This includes employment, consultancies, honoraria, stock ownership or options, expert testimony, grants or patents received or pending, or royalties.No writing assistance was utilized in the production of this manuscript.PDF download" @default.
- W2146993893 created "2016-06-24" @default.
- W2146993893 creator A5026097984 @default.
- W2146993893 creator A5084077585 @default.
- W2146993893 date "2011-02-01" @default.
- W2146993893 modified "2023-10-01" @default.
- W2146993893 title "Phospholipid-based matrix effects in LC–MS bioanalysis" @default.
- W2146993893 cites W1973703658 @default.
- W2146993893 cites W1979575164 @default.
- W2146993893 cites W1997718624 @default.
- W2146993893 cites W2000335858 @default.
- W2146993893 cites W2017506281 @default.
- W2146993893 cites W2021368537 @default.
- W2146993893 cites W2022886298 @default.
- W2146993893 cites W2029322933 @default.
- W2146993893 cites W2037223524 @default.
- W2146993893 cites W2041480771 @default.
- W2146993893 cites W2048897397 @default.
- W2146993893 cites W2054339391 @default.
- W2146993893 cites W2072308918 @default.
- W2146993893 cites W2083670529 @default.
- W2146993893 cites W2096187073 @default.
- W2146993893 cites W2097781250 @default.
- W2146993893 cites W2121017162 @default.
- W2146993893 cites W2121129723 @default.
- W2146993893 cites W2128817061 @default.
- W2146993893 cites W2144871116 @default.
- W2146993893 cites W2152311269 @default.
- W2146993893 cites W2157240187 @default.
- W2146993893 cites W2168526937 @default.
- W2146993893 cites W4234537124 @default.
- W2146993893 doi "https://doi.org/10.4155/bio.10.213" @default.
- W2146993893 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/21338253" @default.
- W2146993893 hasPublicationYear "2011" @default.
- W2146993893 type Work @default.
- W2146993893 sameAs 2146993893 @default.
- W2146993893 citedByCount "45" @default.
- W2146993893 countsByYear W21469938932012 @default.
- W2146993893 countsByYear W21469938932013 @default.
- W2146993893 countsByYear W21469938932014 @default.
- W2146993893 countsByYear W21469938932015 @default.
- W2146993893 countsByYear W21469938932016 @default.
- W2146993893 countsByYear W21469938932017 @default.
- W2146993893 countsByYear W21469938932018 @default.
- W2146993893 countsByYear W21469938932019 @default.
- W2146993893 countsByYear W21469938932020 @default.
- W2146993893 countsByYear W21469938932021 @default.
- W2146993893 countsByYear W21469938932022 @default.
- W2146993893 countsByYear W21469938932023 @default.
- W2146993893 crossrefType "journal-article" @default.
- W2146993893 hasAuthorship W2146993893A5026097984 @default.
- W2146993893 hasAuthorship W2146993893A5084077585 @default.
- W2146993893 hasConcept C106487976 @default.
- W2146993893 hasConcept C137535248 @default.
- W2146993893 hasConcept C162356407 @default.
- W2146993893 hasConcept C175467004 @default.
- W2146993893 hasConcept C185592680 @default.
- W2146993893 hasConcept C2778918659 @default.
- W2146993893 hasConcept C41625074 @default.
- W2146993893 hasConcept C43617362 @default.
- W2146993893 hasConcept C55493867 @default.
- W2146993893 hasConcept C64489805 @default.
- W2146993893 hasConceptScore W2146993893C106487976 @default.
- W2146993893 hasConceptScore W2146993893C137535248 @default.
- W2146993893 hasConceptScore W2146993893C162356407 @default.
- W2146993893 hasConceptScore W2146993893C175467004 @default.
- W2146993893 hasConceptScore W2146993893C185592680 @default.
- W2146993893 hasConceptScore W2146993893C2778918659 @default.
- W2146993893 hasConceptScore W2146993893C41625074 @default.
- W2146993893 hasConceptScore W2146993893C43617362 @default.
- W2146993893 hasConceptScore W2146993893C55493867 @default.
- W2146993893 hasConceptScore W2146993893C64489805 @default.
- W2146993893 hasIssue "4" @default.
- W2146993893 hasLocation W21469938931 @default.
- W2146993893 hasLocation W21469938932 @default.
- W2146993893 hasOpenAccess W2146993893 @default.
- W2146993893 hasPrimaryLocation W21469938931 @default.
- W2146993893 hasRelatedWork W1838573891 @default.
- W2146993893 hasRelatedWork W1986686938 @default.
- W2146993893 hasRelatedWork W2004208954 @default.
- W2146993893 hasRelatedWork W2010997683 @default.
- W2146993893 hasRelatedWork W2019140910 @default.
- W2146993893 hasRelatedWork W2023115092 @default.
- W2146993893 hasRelatedWork W2062405252 @default.
- W2146993893 hasRelatedWork W2105096041 @default.
- W2146993893 hasRelatedWork W2329583206 @default.
- W2146993893 hasRelatedWork W3028635380 @default.
- W2146993893 hasVolume "3" @default.
- W2146993893 isParatext "false" @default.
- W2146993893 isRetracted "false" @default.
- W2146993893 magId "2146993893" @default.
- W2146993893 workType "article" @default.