Matches in SemOpenAlex for { <https://semopenalex.org/work/W2169921720> ?p ?o ?g. }
Showing items 1 to 95 of
95
with 100 items per page.
- W2169921720 endingPage "416" @default.
- W2169921720 startingPage "410" @default.
- W2169921720 abstract "We compared the airflow resistance of 7.5 and 8.5 mm internal diameter (i.d.) endotracheal tubes (ETTs) with that of a size 4 laryngeal mask airway (LMA†). We thought that any difference in the resistance of the devices alone might be offset by the resistance of the larynx. Sixteen adult ASA physical status I and II patients (14 males, two females) undergoing general anaesthesia were anaesthetized and paralysed with intravenous propofol, ketamine and vecuronium. After insertion of the LMA, controlled ventilation (tidal volume 10 ml kg−1, frequency 12 min−1) was established with three different settings for inspiratory flow (5.5, 7.5 and 12.5 ml kg−1 s−1). Ventilation with the same settings was used after orotracheal intubation with an ETT of i.d. 7.5 mm (females) or 8.5 mm (males). The position of the LMA mask and the tip of the ETT were checked through a fibrescope. The resistance of the devices and, in case of the LMA, of the larynx, was derived by relating proximal and distal pressures (measured via catheters) to inspiratory flow. Four patients—young, tall men—had to be excluded from further study because of a leak around the LMA. In the remaining 10 males and two females, resistance of the LMA (mean (sd) at high flow, 1.19 (0.22) mbar·s litre−1 in males) was less than that of the 8.5 mm i.d. ETT (3.34 (0.52) mbar·s litre−1) (P<0.01). However, the structures between the LMA and the trachea added another, highly variable, resistance component, so that the mean resistance of the LMA and larynx together was similar (in males: 3.20 (2.71) mbar·s litre−1) to that of the 8.5 mm ETT. In eight patients the epiglottis projected on to one-tenth to two-thirds of the distal opening of the LMA; this was in no case associated with greater resistance. Greater resistance occurred in two patients with a central LMA position and unobstructed view of the glottis and in one patient with marked lateral deviation. In conclusion, there is no clinically relevant difference between the resistance of a size 4 LMA plus that of the larynx and that of an 8.5 mm i.d. ETT. We compared the airflow resistance of 7.5 and 8.5 mm internal diameter (i.d.) endotracheal tubes (ETTs) with that of a size 4 laryngeal mask airway (LMA†). We thought that any difference in the resistance of the devices alone might be offset by the resistance of the larynx. Sixteen adult ASA physical status I and II patients (14 males, two females) undergoing general anaesthesia were anaesthetized and paralysed with intravenous propofol, ketamine and vecuronium. After insertion of the LMA, controlled ventilation (tidal volume 10 ml kg−1, frequency 12 min−1) was established with three different settings for inspiratory flow (5.5, 7.5 and 12.5 ml kg−1 s−1). Ventilation with the same settings was used after orotracheal intubation with an ETT of i.d. 7.5 mm (females) or 8.5 mm (males). The position of the LMA mask and the tip of the ETT were checked through a fibrescope. The resistance of the devices and, in case of the LMA, of the larynx, was derived by relating proximal and distal pressures (measured via catheters) to inspiratory flow. Four patients—young, tall men—had to be excluded from further study because of a leak around the LMA. In the remaining 10 males and two females, resistance of the LMA (mean (sd) at high flow, 1.19 (0.22) mbar·s litre−1 in males) was less than that of the 8.5 mm i.d. ETT (3.34 (0.52) mbar·s litre−1) (P<0.01). However, the structures between the LMA and the trachea added another, highly variable, resistance component, so that the mean resistance of the LMA and larynx together was similar (in males: 3.20 (2.71) mbar·s litre−1) to that of the 8.5 mm ETT. In eight patients the epiglottis projected on to one-tenth to two-thirds of the distal opening of the LMA; this was in no case associated with greater resistance. Greater resistance occurred in two patients with a central LMA position and unobstructed view of the glottis and in one patient with marked lateral deviation. In conclusion, there is no clinically relevant difference between the resistance of a size 4 LMA plus that of the larynx and that of an 8.5 mm i.d. ETT. The laryngeal mask airway (LMA†) is popular as an airway during general anaesthesia. Unlike an endotracheal tube (ETT), it can be inserted into the pharynx without laryngoscopy and neuromuscular blockade and is the airway of choice for short procedures not requiring muscle paralysis; however, it is more frequently used for longer operations with controlled ventilation as well. The LMA provides an adjunct which can be joined to the airway end-to-end, to avoid the reduction in diameter that happens when one tube (the ETT) is inserted into the lumen of another (the trachea).1Brain AIJ The laryngeal mask—a new concept in airway management.Br J Anaesth. 1983; 55: 801-805Crossref PubMed Scopus (775) Google Scholar Indeed, the tube part of a standard LMA is shorter and wider than a corresponding ETT. Bhatt and co-workers2Bhatt SB Kendall AP Lin ES Oh TE Resistance and additional inspiratory work imposed by the laryngeal mask airway.Anaesthesia. 1992; 47: 343-347Crossref PubMed Scopus (39) Google Scholar found the resistance of an LMA was between one-sixth and half of that of a comparable ETT, depending on size and flow. They suggested that a patient breathing spontaneously would have to expend less work breathing on an LMA. This ignores the fact that the ETT ends in the trachea, i.e. beyond the glottis, while the LMA ends before the laryngeal entrance. The inspiratory resistance of the larynx should be added to that of the LMA for a true comparison. We compared the inspiratory resistance of a standard ETT with that of a corresponding LMA plus the larynx. We hypothesized that any difference in resistance of the devices alone would be offset by the additional resistance of the larynx. Another aim of the study was to investigate how LMA position affected airflow resistance. Previous studies3Brimacombe J Analysis of 1500 laryngeal mask uses by one anaesthetist in adults undergoing routine anaesthesia.Anaesthesia. 1996; 51: 76-80Crossref PubMed Scopus (160) Google Scholar, 4Brimacombe J Berry A Insertion of the laryngeal mask airway—a prospective study of four techniques.Anaesth Intens Care. 1993; 21: 89-92Crossref PubMed Google Scholar, 5Pothmann W Füllekrug B Schulte am Esch J Fiberoptische Befunde zum Sitz der Kehlkopfmaske.Anaesthesist. 1992; 41: 779-784PubMed Google Scholar, 6Füllekrug B Pothmann W Werner C Schulte am Esch J The laryngeal mask airway: anesthetic gas leakage fiberoptic control of positioning.J Clin Anesth. 1993; 5: 357-363Abstract Full Text PDF PubMed Scopus (35) Google Scholar, 7Nandi PR Nunn JF Charlesworth CH Taylor SJ Radiologic study of the laryngeal mask.Eur J Anaesthesiol. 1991; : 33-39PubMed Google Scholar, 8Payne J The use of fibreoptic laryngoscope to confirm the position of the laryngeal mask.Anaesthesia. 1989; 44: 865Crossref PubMed Scopus (93) Google Scholar, 9Shorten GD Opie NJ Graziotti P Morris I Khangure M Assessment of upper airway anatomy in awake, sedated and anaesthetized patients using magnetic resonance imaging.Anaesth Intens Care. 1994; 22: 165-169PubMed Google Scholar have shown that deviations from a central position are common and that the epiglottis can project into a considerable proportion of the air passage in many patients. It has been suggested8Payne J The use of fibreoptic laryngoscope to confirm the position of the laryngeal mask.Anaesthesia. 1989; 44: 865Crossref PubMed Scopus (93) Google Scholar 10Brodrick PM Webster NR Nunn JF The laryngeal mask airway—a study of 100 patients during spontaneous breathing.Anaesthesia. 1989; 44: 238-241Crossref PubMed Scopus (176) Google Scholar that these variations in position are associated with increased airflow resistance, but no data have been presented to support or reject this assumption. After approval by the Hamburg board of physicians ethics committee, and with their written informed consent, 16 patients scheduled and regularly prepared for elective trauma, general or urological surgery were enrolled. Exclusion criteria were morbid obesity (weight >130% of norm), coagulation abnormalities, systemic disease, allergies, malformations or diseases of the head, neck, thorax or abdomen or the structures and organs within them. The patients received oral midazolam (5.0–7.5 mg). For the study they were placed supine with the head resting on a 5 cm thick foam cushion. Anaesthesia was induced and maintained with propofol (2–3 mg kg−1 and infusion 6–12 mg kg−1 h−1) and ketamine (1.0–1.5 mg kg−1 initially with repeated doses) after atropine 0.5–1.0 mg for reduction of secretions. Ketamine was used for analgesia in order to avoid the effects of opioids on chest wall mechanics. For the first part of the study, a size 4 LMA (Intavent (Cyprus) Ltd, Nicosia, Cyprus) was inserted by a standard technique, and its cuff was inflated with the recommended amount of air (30 ml). Absence of leaks was verified by ventilation with positive pressure. If leaks were detected by auscultation, the LMA was repositioned up to three times. The study was continued only if an apparently leak-free position was obtained. The position of the LMA relative to the structures of the larynx was inspected with a fibre-bronchoscope (type BF P30, Olympus Optical Co. (Europe), Hamburg, Germany). Special attention was given to lateral deviation and to the proportion of the field of vision occupied by the epiglottis when looking from inside the distal opening. In all patients, the same experienced anaesthetist inserted the LMA and did the laryngoscopy. A standard cuffed ETT (Mallinckrodt lopro, Mallinckrodt Medical, Hennef, Germany, internal diameter (i.d.) 7.5 mm for female patients, 8.5 mm for males) was used in the second part of the study, inserted through the mouth by conventional direct laryngoscopy. The position in the trachea was checked fibreoptically. Because of the limited length of the pressure-measuring catheter (see below), the ETTs had to be shortened to 24 cm at the proximal end. Since the length of an airway has only minor impact on its resistance,11Guttmann J Eberhard L Fabry B Bertschmann W Wolff G Continuous calculation of intratracheal pressure in tracheally intubated patients.Anesthesiology. 1993; 79: 503-513Crossref PubMed Scopus (162) Google Scholar this shortening should not have influenced our results. The devices were attached to the patient circuit of a standard anaesthesia machine (Cicero, Drägerwerk AG, Lübeck, Germany) via a 90° swivel bronchoscopy connector, a bacterium filter (type BB22-15M; Pall, Newquay, UK), and a combination of pneumotachygraph and proximal airway opening pressure (Pao) tap (side stream spirometer; Datex Instrumentarium Corp., Helsinki, Finland). A pressure-measuring catheter of 2.5 mm outer diameter, with closed tip and side holes (K-31; Baxter Healthcare Corporation, Deerfield, IL, USA) was placed through the LMA or ETT with the tip guided into the trachea under direct vision using a bronchoscope (‘distal’ catheter). An identical catheter was placed with its tip in the proximal end of the devices close to the swivel connector (‘connector’ catheter) and both were attached to individual transducers (Medex, Klein Winternheim, Germany) measuring pressure relative to atmosphere. The catheters were flushed with air frequently throughout the study; this reliably prevented plugging by mucus or condensation. Signals from these pressure transducers and from the sidestream spirometer (flow and Pao) were displayed on a monitor (ASIII; Datex) and stored on a personal computer after digitizing at 100 Hz. The monitor was calibrated according to the manufacturer's specifications; standard pressures and a standard volume were recorded on the computer before each study for correction of the digitized signals. Earlier tests had shown that the ASIII monitor delays signal output by 50 ms (pressures) or 250 ms (signals from the sidestream spirometer). The tracks of the digital recordings were shifted appropriately, so the remaining phase shift between signals was <10 ms. Linearity and symmetry were verified for pressure measurements by appropriate reference pressures and for the flow measurement by applying the calibration volume (1 litre) in both directions with a wide range of flows. Arterial pressure (cuff), heart rate (ECG), oxyhaemoglobin saturation (pulse oximeter) and endtidal Pco2 were monitored throughout the study (Marquette Electronics Inc., Milwaukee, WI, USA; Draegerwerk AG). The patients were ventilated with 50% oxygen in nitrogen in intermittent positive pressure ventilation mode with 12 breaths min−1, a tidal volume of 10 ml kg−1 and an inspiratory:expiratory time (I:E) ratio of 1:1.5. To obtain measurements at different inspiratory flow rates while keeping tidal volume and I:E ratio constant, the relation between the inspiratory flow phase and end inspiratory pause was varied: Each measurement block consisted of three sets of 10–30 breaths each with an end inspiratory pause of 0%, 30% and 60% of inspiratory time, respectively, resulting in flows of 5.5, 7.5 and 12.5 ml kg−1 s−1, respectively. With each device, one block of measurements was made with the ‘distal’ catheter located in the trachea and one after retraction of this catheter to the ‘connector’ position. By comparing the data from the two blocks, the effect of the catheter on the devices’ resistance could be estimated. In eight patients, another block of measurements was made with the tip of the ‘distal’ catheter located in the distal opening of the LMA, so in these patients the resistance of the LMA could be distinguished from that of the larynx. To avoid unnecessary manipulation in the patients’ upper airway, the LMA was studied first in all patients. The ETT was then placed and left there for the rest of the anaesthesia. Since the variables measured were bound to be independent of time, we did not expect the order to have any effect. As endotracheal intubation was facilitated routinely by neuromuscular blockade, both devices were studied after administration of vecuronium (0.1 mg kg−1 initially, repeat doses of 0.05 mg kg−1 after 30 min) to allow comparability. In five patients additional measurements were made with the LMA before giving the relaxant, to provide data on the effects of neuromuscular blockade. The recorded signals were supplemented with a trace for the drop in resistive pressure along the devices and the larynx. This was obtained by digitally subtracting the pressure measured with the ‘distal’ catheter from that at the ‘connector’ catheter. The flow signal was digitally integrated for calculation of tidal volume. Flow during the last 500 ms of inspiration was used as the denominator in resistance calculations. All respiratory mechanics results were means from the last six breaths of each setting. Resistance values were calculated primarily by dividing the drop in resistive pressure between the connector and the trachea (and between the connector and tip of the LMA in eight patients) by the simultaneously measured flow values. However, this resistance was, inevitably, increased artificially by the ‘distal’ catheter passing through the devices and the larynx. The data were corrected for this artefact by a second method for resistance calculation: When inspiratory flow stops, pressures throughout the respiratory system decrease suddenly, because the resistive loads distal to any point of measurement no longer have to be addressed by a driving pressure component. If an end inspiratory pause follows the cessation of flow, as in our study in the setting with medium and high flows, the difference between the peak pressure immediately preceding the cessation and the value directly after it (ΔP1) can be divided by the flow before cessation, yielding resistance of all structures distal to the point of measurements 12von Neergard K Wirz R Die Messung der Strömungswiderstände in den Atemwegen des Menschen, insbesondere bei Asthma und Emphysem.Z Klin Med. 1927; 105: 51-82Google Scholar. In this study the ΔP1 method was applied to Pao; comparison of the values with the ‘distal’ catheter in the trachea or at the tip of the LMA, respectively, to those after retraction to the ‘connector’ position allowed quantification of the increased resistance caused by the catheter passing through the structures of interest when in the ‘distal’ position. The catheter-derived resistances were corrected for this artefact. Since the artefact could only be quantified at medium and high flows (see above), corrected resistance values are available only for those settings. Since the ΔP1 method is prone to noise, the artefact correction introduced a certain amount of scatter, but this did not influence the main findings of the study. Theoretically, simple differences between the resistances of the devices could have been measured entirely based on the ΔP1 method, obviating the need for catheter measurements. This simplification, however, would have generated several problems: (i) no absolute values of resistance would have been available, making comparison with published data difficult; (ii) intubation-related changes in resistance of structures distal to the trachea, i.e. bronchi, lung parenchyma and chest wall, could not have been distinguished from changes of the values under study, thus introducing a substantial source of error; (iii) separate consideration of LMA and larynx would not have been possible. Data are reported as means (sd) unless stated otherwise. Since comparison of devices always included ETTs, only the data for the male patients were tested by Wilcoxon's ranked sign test; differences were considered significant if P was <0.05 (SYSTAT version 5.1 under MacOS). There were too few female patients for statistical testing to be valid for data from these patients. Data from 12 of the patients were available for analysis. In two patients, audible leaks around the LMA persisted despite careful repositioning, so study of these patients was cancelled before any data acquisition; in another two, analysis of inspiratory and expiratory tidal volume indicated a leak of >100 ml breath−1 when lungs were ventilated through the LMA, so data from these patients were excluded from further analysis. All patients excluded were young, tall men. Table 1 summarizes the patient characteristics.Table 1Patient characteristicsPatientGenderAge (yr)Weight (kg)1male52752female35903male50824male67955male43746female52677male59728male27709male656310male587311male566412male6482Median54.0073.50Range27–6763–95 Open table in a new tab Figure 1 shows the inspiratory resistance of LMA alone (left panel), LMA plus larynx (middle) and ETT (right) as a function of flow before correction for the artificial increase in resistance by the ‘distal’ catheter in place. Plots spanning corresponding flow values in the three panels refer to the same patient, as flow was determined by tidal volume and thus by body weight. Low flow was on average 0.45 litres s−1, medium flow 0.63 litres s−1 and high flow 1.05 litres s−1. Three main observations can be made: (i) the resistance of the LMA alone and of the ETT had a nearly linear flow–resistance relationship; scatter was negligible; (ii) the resistance of the LMA alone was smallest, while that of the 7.5 mm i.d. ETT used for the two females was greatest; (iii) anatomical structures distal to the LMA showed a highly variable additional resistance. Figure 2 shows the corresponding resistance after correction for the catheter artefact. Since the correction was based on the ΔP1 method and required an end inspiratory pause, only values from medium and high flows were available. The data, taken in conjunction with those from the corresponding panels of Figure 1, allow several conclusions: (i) the correction slightly increased the scatter; (ii) as expected, the additional resistance caused by the measuring catheter is lowest in the device with the widest lumen, i.e. the LMA (0.33 (0.29) mbarċs litre−1 at high flow), and increases with narrowing of the lumen (8.5 mm i.d. ETT, 1.74 (0.32) mbarċs litre−1; 7.5 mm i.d., 4.31 (0.05) mbarċs litre−1); (iii) the resistance of the structures between the LMA and the trachea was nearly as high and variable as before correction. In Figure 3, the corrected resistance data are presented in a different way to improve the presentation of group mean data. Standard deviations are only shown for males. The resistance of the devices alone corresponded to that found by other authors:2Bhatt SB Kendall AP Lin ES Oh TE Resistance and additional inspiratory work imposed by the laryngeal mask airway.Anaesthesia. 1992; 47: 343-347Crossref PubMed Scopus (39) Google Scholar 11Guttmann J Eberhard L Fabry B Bertschmann W Wolff G Continuous calculation of intratracheal pressure in tracheally intubated patients.Anesthesiology. 1993; 79: 503-513Crossref PubMed Scopus (162) Google Scholar 13Al-Hasani A Resistance to constant air flow imposed by the standard laryngeal mask, the reinforced laryngeal mask and RAE tracheal tubes.Br J Anaesth. 1993; 71: 594-596Crossref PubMed Scopus (14) Google Scholar 18Boisson-Bertrand D Hannhart B Rousselot JM Duvivier C Quilici N Peslin R Comparative effects of laryngeal mask and tracheal tube on total respiratory resistance in anaesthetized patients.Anaesthesia. 1994; 49: 846-849Crossref PubMed Scopus (12) Google Scholar that of the LMA (1.19 (0.22) mbarċs litre−1 in males and 1.98 (0.44) mbarċs litre−1 in females, at high flow) was smaller than that of the ETT (3.34 (0.52) mbarċs litre−1 for 8.5 mm i.d (P<0.01 versus LMA) and 6.39 (2.50) mbarċs litre−1 for 7.5 mm i.d.). The resistance of LMA plus larynx, however (3.20 (2.71) mbarċs litre−1 in males, 6.14 (4.27) mbarċs litre−1 in females) was similar to that of the ETT (P>0.1; only males compared). As in the other figures, the scatter of resistance was largest for LMA plus larynx, suggesting high variability in the resistance of the structures distal to the LMA. One each of the male and female patients showed excessively high resistance of the larynx; because fewer females were studied, the impact on the mean value was much larger in the female subgroup. In the other female patient the resistance of the larynx was in the same range as that of a male larynx. The data for the LMA alone and the 8.5 mm i.d. ETT were fitted to a common second-order polynomial equation, Rohrer's equation, relating the pressure drop, ΔP, along a tube to the flow through it: ΔP = (K1 × flow) + (K2 × flow2Bhatt SB Kendall AP Lin ES Oh TE Resistance and additional inspiratory work imposed by the laryngeal mask airway.Anaesthesia. 1992; 47: 343-347Crossref PubMed Scopus (39) Google Scholar) In this study, K1 and K2 for the LMA were 0.08 and 1.54 respectively (so ΔP was 1.62 mbar at a flow rate of 1 litre s−1), while those for the ETT were 0.32 and 3.21, respectively (so ΔP was 3.53 mbar at a flow rate of 1 litre s−1). This underscores the similarity between the resistance found in the present study and those reported previously.2Bhatt SB Kendall AP Lin ES Oh TE Resistance and additional inspiratory work imposed by the laryngeal mask airway.Anaesthesia. 1992; 47: 343-347Crossref PubMed Scopus (39) Google Scholar 11Guttmann J Eberhard L Fabry B Bertschmann W Wolff G Continuous calculation of intratracheal pressure in tracheally intubated patients.Anesthesiology. 1993; 79: 503-513Crossref PubMed Scopus (162) Google Scholar Confidence intervals for resistance values are not reported, because the variability caused by individual differences in flow rate would have to be eliminated first by deriving a resistance value at a normalized flow. For the devices alone this can be done by fitting the data as described in the paragraph above. However, the absence of such a clear relationship for the most interesting data, namely those from the LMA plus larynx, precludes such procedure in this context. Table 2 summarizes endoscopic findings and other observations. Resistance data for the LMA plus larynx are included as reference. Two patients made a whooping noise during inspiration when ventilated through the LMA, and one showed a marked lateral deviation of the LMA; these were the three patients with especially high resistance of LMA plus larynx. In eight patients the epiglottis covered between one-tenth and two-thirds of the distal opening of the LMA, but this was not associated with increased resistance. In the two patients with a whoop and high resistance, the epiglottis could not be seen; the entire glottis could be seen from the distal opening of the LMA.Table 2Endoscopy. ‘Distal opening’ is the proportion of the field of vision occupied by the epiglottis (E) or anterior wall of the trachea (AW). Patients 2 and 4 made a whooping sound during inspiration through LMALMAPatientETT endoscopyLeakage (ml per ml of tidal volume)EndoscopyResistance including larynx (mbar s–1 litre–1)DeviationDistal openingDeviationDistal opening of endoscope1−−0left1/10 (E)1.802−−0−09.163−−0right2/3 (E)3.304−−30/970−010.305left−0left01.416−−60/690−1/4 (E)3.127−−0−1/4 (E)2.218−1/3 (AW)0−1/2 (E)1.849−−0dorsal00.7010−−0−4/10 (E)2.6711−−0right1/2 (E)4.29(marked)12−−0−1/2 (E)3.45 Open table in a new tab We found that there was less airflow resistance with a size 4 LMA than with a corresponding ETT. The anatomical structures between the LMA and the trachea imposed an additional highly variable resistance, so overall resistive pressure drops between the airway opening and the trachea were of the same magnitude. The resistance of artificial airways is of interest because a spontaneously breathing patient has to work to overcome it. Previous in vitro studies2Bhatt SB Kendall AP Lin ES Oh TE Resistance and additional inspiratory work imposed by the laryngeal mask airway.Anaesthesia. 1992; 47: 343-347Crossref PubMed Scopus (39) Google Scholar 13Al-Hasani A Resistance to constant air flow imposed by the standard laryngeal mask, the reinforced laryngeal mask and RAE tracheal tubes.Br J Anaesth. 1993; 71: 594-596Crossref PubMed Scopus (14) Google Scholar found that the resistance and the additional work of breathing caused by standard LMAs are approximately one-sixth to half of those elicited by comparable ETTs (the range reflects the fact that there is a range of ETT sizes corresponding to a single LMA size). This difference is not surprising considering the larger diameter of the LMA tube: the work of breathing is inversely related to the third to fourth power of the tube diameter,14Bolder PM Healy TEJ Bolder AR Beatty PCW Kay B. The extra work of breathing through adult endotracheal tubes.Anesth Analg. 1986; 65: 853-859Crossref PubMed Scopus (90) Google Scholar depending on breathing pattern, while length only makes a minor difference.11Guttmann J Eberhard L Fabry B Bertschmann W Wolff G Continuous calculation of intratracheal pressure in tracheally intubated patients.Anesthesiology. 1993; 79: 503-513Crossref PubMed Scopus (162) Google Scholar The recently introduced reinforced LMAs have narrower tubes, so their resistance is greater than that of standard LMAs and similar to that of ETTs.13Al-Hasani A Resistance to constant air flow imposed by the standard laryngeal mask, the reinforced laryngeal mask and RAE tracheal tubes.Br J Anaesth. 1993; 71: 594-596Crossref PubMed Scopus (14) Google Scholar However, an ETT bridges the larynx and thus eliminates its resistance. Thus, work while breathing through an ETT has been found to be equivalent to that during breathing through a standard LMA, and even less than that during breathing through a reinforced LMA with its narrower tube.13Al-Hasani A Resistance to constant air flow imposed by the standard laryngeal mask, the reinforced laryngeal mask and RAE tracheal tubes.Br J Anaesth. 1993; 71: 594-596Crossref PubMed Scopus (14) Google Scholar We found that the anatomical structures between the LMA and trachea had a sizeable and highly variable resistance of their own. On average, this resistance (the difference between the resistance determined for the LMA alone and that of the LMA plus larynx) amounted to 2.3 mbarċs litre−1 at high flow and reduced the differences between LMA and ETT resistance to insignificant and clinically irrelevant amounts. These results support those of Ferguson and colleagues,15Ferguson C Herdman M Evans K Hayes M Cole PV Flow resistance of the laryngeal mask in awake subjects.Br J Anaesth. 1991; 66: 400PGoogle Scholar who studied spontaneously breathing awake volunteers. They found that the resistance of the airways including an LMA was similar to that found for airways including an ETT by Gal and Suratt.16Gal TJ Suratt PM Resistance to breathing in healthy subjects following endotracheal intubation under topical anesthesia.Anesth Analg. 1980; 59: 270-274Crossref PubMed Scopus (52) Google Scholar Normal upper airway resistance is between 0.5 and 1.0 mbarċs litre−1 during quiet breathing,17Ferris Jr, BG Mead J Opie LH Partitioning of respiratory flow resistance in man.J Appl Physiol. 1964; 19: 653-658Crossref PubMed Scopus (285) Google Scholar i.e. at flows comparable to the medium or low flows in our study. In contrast, Boisson-Bertrand and co-workers18Boisson-Bertrand D Hannhart B Rousselot JM Duvivier C Quilici N Peslin R Comparative effects of laryngeal mask and tracheal tube on total respiratory resistance in anaesthetized patients.Anaesthesia. 1994; 49: 846-849Crossref PubMed Scopus (12) Google Scholar found that the upper airways did not contribute to the overall resistance of the respiratory system resistance during mechanical ventilation via an LMA. The discrepancy might be result from the fact that upper airway resistance was not measured directly in that study. Because of the small number of patients, the present study might not show a true difference between the resistance of the ETT and that of an LMA plus larynx. However, because of the high variability of laryngeal resistance, many patients would have to be studied to find a difference, which cannot be expected to be of a clinically relevant magnitude. The relevance of the additional work of breathing imposed by airways can also be questioned in general. This work component is of the same order of magnitude as that naturally imposed by the respiratory system, and healthy adults should be able to easily overcome it with the force reserve of their respiratory muscles. However, the resistance of the structures between a LMA and the trachea is clinically relevant from a different point of view: major complications known to be associated with the use of the LMA,19Leach AB Alexander CA The laryngeal mask—an overview.Eur J Anaesthesiol. 1991; : 19-31Google Scholar i.e. laryngospasm and bronchospasm, likewise increase resistance, often immediately after LMA insertion. The anaesthetist has to distinguish these complications from an increase in resistance for mechanical reasons. The latter requires a different therapy, if any (namely repositioning of the device), which is not indicated in the case of laryngospasm or bronchospasm.19Leach AB Alexander CA The laryngeal mask—an overview.Eur J Anaesthesiol. 1991; : 19-31Google Scholar 20Brain AIJ Studies on the laryngeal mask—first, learn the art.Anaesthesia. 1991; 46: 417-418Crossref PubMed Scopus (22) Google Scholar It might be reasonable to increase the depth of anaesthesia at first, perform auscultation for differential diagnosis, and then attempt to reposition the device. The study also aimed to discover the degree to which highly variable resistance of the larynx and the surrounding structures might be related to individual differences in the interactions of the LMA with the upper airway. The position of the epiglottis relative to the LMA has been of concern for several authors. Studies using magnetic resonance imaging, conventional radiography and/or fibreoptic endoscopy showed that, in 35–65% of patients, the epiglottis comes to lie within the cuff of the LMA and in most of these is folded down.3Brimacombe J Analysis of 1500 laryngeal mask uses by one anaesthetist in adults undergoing routine anaesthesia.Anaesthesia. 1996; 51: 76-80Crossref PubMed Scopus (160) Google Scholar 5Pothmann W Füllekrug B Schulte am Esch J Fiberoptische Befunde zum Sitz der Kehlkopfmaske.Anaesthesist. 1992; 41: 779-784PubMed Google Scholar−9 The epiglottis might occupy up to 100% of the field of view when looking down on the distal opening of the LMA with a fibrescope. This has been postulated to be a potential reason for obstruction,8Payne J The use of fibreoptic laryngoscope to confirm the position of the laryngeal mask.Anaesthesia. 1989; 44: 865Crossref PubMed Scopus (93) Google Scholar 10Brodrick PM Webster NR Nunn JF The laryngeal mask airway—a study of 100 patients during spontaneous breathing.Anaesthesia. 1989; 44: 238-241Crossref PubMed Scopus (176) Google Scholar but a correlation has not been found. As Brain points out,20Brain AIJ Studies on the laryngeal mask—first, learn the art.Anaesthesia. 1991; 46: 417-418Crossref PubMed Scopus (22) Google Scholar the endoscopic view is two-dimensional, so the fact that the epiglottis can be seen—even in large parts of the field of view—does not preclude air from passing around it. Our study supports the notion that visibility of the epiglottis is not associated with a marked increase in resistance. Indeed, in the two patients in whom resistance was greatest, the view of the glottis was completely unobstructed. As the visibility of the epiglottis was not associated with increased resistance, no attempts were made to quantify the area of visual obstruction more precisely or to correct for the geometry of the fibrescope. Nandi and co-workers7Nandi PR Nunn JF Charlesworth CH Taylor SJ Radiologic study of the laryngeal mask.Eur J Anaesthesiol. 1991; : 33-39PubMed Google Scholar point to an important potential mechanism for obstruction. They found that the typical anterior displacement of the cricoid cartilage by the blocked LMA might render the vocal cords short, slack and partially adducted. In our study, both patients with high resistance were ventilated with relatively high tidal volumes (and, thus, inspiratory flows) because of their high body weight. The whooping sound associated with inspiration in these, and only these, patients gave rise to the suspicion that the inspiratory flow itself caused a narrowing of the glottis by a Bernoulli-like effect of flow limitation in an elastic tube. We also noted that, in one patient, the overall resistance diminished when the measuring catheter was retracted from the glottis. This resembled findings by Pedersen and Ingram,21Pedersen OF Ingram Jr, RH Configuration of maximum expiratory flow–volume curve: model experiments with physiological implications.J Appl Physiol. 1985; 58: 1305-1313PubMed Google Scholar who showed that a foreign body introduced into an elastic tube can promote collapse and aggravate flow limitation. Righini and colleagues22Righini ER Marangoni E Volta CA Alvisi R Bortolazzi S Gritti G Additional inspiratory resistance imposed by the laryngeal mask airway: in vitro versus in vivo comparison.Anaesthesia. 1997; 52: 872-878Crossref PubMed Scopus (7) Google Scholar found that the inspiratory resistance shown by a size 3 LMA while in situ in five patients was almost twice that measured in vitro. These authors speculated that this was caused by a narrowing of the distal LMA opening brought about by blocking the LMA cuff within the hypopharynx. However, the distal pressure was measured with a catheter extending 15 mm beyond the distal opening. Our endoscopic findings suggest that, in this position, Righini and co-workers were already measuring a considerable part of the resistance posed by the anatomical structures, so that conformational changes of the LMA outlet might not have had the impact ascribed to it by these authors. In conclusion, we found no statistically significant or clinically relevant difference between the resistance of a size 4 LMA plus that of the larynx and that of an 8.5 mm i.d. ETT. The resistance of the anatomical structures between the LMA and the trachea is sizeable and highly variable. These findings extend and complement previous in vitro studies. In addition, they suggest that an LMA might change upper airway geometry in a way that promotes elevation of resistance. The authors thank the anaesthesia nurses of the department for their co-operation and the Hoyer Engström company for the loan of a Datex AS III monitor." @default.
- W2169921720 created "2016-06-24" @default.
- W2169921720 creator A5002163808 @default.
- W2169921720 creator A5009729501 @default.
- W2169921720 creator A5027196228 @default.
- W2169921720 creator A5037320109 @default.
- W2169921720 creator A5088883499 @default.
- W2169921720 date "2000-09-01" @default.
- W2169921720 modified "2023-10-11" @default.
- W2169921720 title "Resistance of laryngeal mask airway and tracheal tube in mechanically ventilated patients †" @default.
- W2169921720 cites W1517812804 @default.
- W2169921720 cites W1991185392 @default.
- W2169921720 cites W1994510116 @default.
- W2169921720 cites W2023660370 @default.
- W2169921720 cites W2024612757 @default.
- W2169921720 cites W2033229199 @default.
- W2169921720 cites W2041028839 @default.
- W2169921720 cites W2058523215 @default.
- W2169921720 cites W2085154682 @default.
- W2169921720 cites W2088339252 @default.
- W2169921720 cites W2095067293 @default.
- W2169921720 cites W2103367239 @default.
- W2169921720 cites W2109328758 @default.
- W2169921720 cites W2132058555 @default.
- W2169921720 cites W2417195995 @default.
- W2169921720 cites W2435381475 @default.
- W2169921720 cites W4237258985 @default.
- W2169921720 doi "https://doi.org/10.1093/bja/85.3.410" @default.
- W2169921720 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/11103183" @default.
- W2169921720 hasPublicationYear "2000" @default.
- W2169921720 type Work @default.
- W2169921720 sameAs 2169921720 @default.
- W2169921720 citedByCount "17" @default.
- W2169921720 countsByYear W21699217202014 @default.
- W2169921720 countsByYear W21699217202016 @default.
- W2169921720 countsByYear W21699217202019 @default.
- W2169921720 countsByYear W21699217202022 @default.
- W2169921720 countsByYear W21699217202023 @default.
- W2169921720 crossrefType "journal-article" @default.
- W2169921720 hasAuthorship W2169921720A5002163808 @default.
- W2169921720 hasAuthorship W2169921720A5009729501 @default.
- W2169921720 hasAuthorship W2169921720A5027196228 @default.
- W2169921720 hasAuthorship W2169921720A5037320109 @default.
- W2169921720 hasAuthorship W2169921720A5088883499 @default.
- W2169921720 hasBestOaLocation W21699217201 @default.
- W2169921720 hasConcept C105922876 @default.
- W2169921720 hasConcept C141071460 @default.
- W2169921720 hasConcept C159985019 @default.
- W2169921720 hasConcept C192562407 @default.
- W2169921720 hasConcept C2776900724 @default.
- W2169921720 hasConcept C2777551473 @default.
- W2169921720 hasConcept C2778112660 @default.
- W2169921720 hasConcept C2778716859 @default.
- W2169921720 hasConcept C2780474809 @default.
- W2169921720 hasConcept C3019038464 @default.
- W2169921720 hasConcept C3020246157 @default.
- W2169921720 hasConcept C33362165 @default.
- W2169921720 hasConcept C42219234 @default.
- W2169921720 hasConcept C71924100 @default.
- W2169921720 hasConceptScore W2169921720C105922876 @default.
- W2169921720 hasConceptScore W2169921720C141071460 @default.
- W2169921720 hasConceptScore W2169921720C159985019 @default.
- W2169921720 hasConceptScore W2169921720C192562407 @default.
- W2169921720 hasConceptScore W2169921720C2776900724 @default.
- W2169921720 hasConceptScore W2169921720C2777551473 @default.
- W2169921720 hasConceptScore W2169921720C2778112660 @default.
- W2169921720 hasConceptScore W2169921720C2778716859 @default.
- W2169921720 hasConceptScore W2169921720C2780474809 @default.
- W2169921720 hasConceptScore W2169921720C3019038464 @default.
- W2169921720 hasConceptScore W2169921720C3020246157 @default.
- W2169921720 hasConceptScore W2169921720C33362165 @default.
- W2169921720 hasConceptScore W2169921720C42219234 @default.
- W2169921720 hasConceptScore W2169921720C71924100 @default.
- W2169921720 hasIssue "3" @default.
- W2169921720 hasLocation W21699217201 @default.
- W2169921720 hasLocation W21699217202 @default.
- W2169921720 hasOpenAccess W2169921720 @default.
- W2169921720 hasPrimaryLocation W21699217201 @default.
- W2169921720 hasRelatedWork W2029517049 @default.
- W2169921720 hasRelatedWork W2088384880 @default.
- W2169921720 hasRelatedWork W2107505766 @default.
- W2169921720 hasRelatedWork W2330418440 @default.
- W2169921720 hasRelatedWork W2352204819 @default.
- W2169921720 hasRelatedWork W2440670172 @default.
- W2169921720 hasRelatedWork W2471071062 @default.
- W2169921720 hasRelatedWork W2492402190 @default.
- W2169921720 hasRelatedWork W4244111096 @default.
- W2169921720 hasRelatedWork W604814998 @default.
- W2169921720 hasVolume "85" @default.
- W2169921720 isParatext "false" @default.
- W2169921720 isRetracted "false" @default.
- W2169921720 magId "2169921720" @default.
- W2169921720 workType "article" @default.