Matches in SemOpenAlex for { <https://semopenalex.org/work/W2189698800> ?p ?o ?g. }
- W2189698800 abstract "Geothermal energy is a promising renewable energy to be used for baseload electricity. Most potential sites with high geothermal temperature are mostly located in remote areas where water is limited. This is besides water scarcity and environmental protection, which made dry cooling systems a better alternative solution for heat rejection of power plants. Furthermore, natural draft cooling towers have the advantage of avoiding parasitic losses introduced by the fans at mechanical draft cooling towers. However, power plants utilizing dry cooling technologies experience a significant reduction in power generation during high ambient temperature periods. This reduction often goes along with the peak power demand which results in a great loss for the power plant owners. In certain instances, dry cooling tower performance can be enhanced during these periods by pre cooling of the inlet air by spraying atomized water into the inlet air. The present study introduces the use of spray cooling for inlet air pre-cooling in natural draft cooling towers. Spray cooling is investigated in this study due to its simplicity, low capital cost, ease of operation and maintenance, and capability of increasing power plant efficiency while consuming only a small amount of water compared to wet cooling towers or other evaporative cooling methods. Although spray cooling has found successful applications in process coolers and gas turbine inlet air cooling, the large scale applications in power industry have been limited. Several issues limit the application in power industry. The main one is the incomplete evaporation of water droplets which can cause corrosion and scaling of heat exchanger surface. Incomplete evaporation also increases operational cost due to water consumption. To the best of our knowledge, a detailed investigation of the spray cooling performance in natural draft dry cooling towers operating environment has not yet been performed. The aim of the current work is to optimise a spray cooling system for inlet air pre- cooling in natural draft dry cooling towers. In the present study, an Eulerian-Lagrangian 3-D numerical model was developed which is capable of simulating evaporating water sprays produced by real nozzles. In order to reproduce real nozzle characteristics in the simulation, a new adaptable method for hollow- cone spray representation in Eulerian-Lagrangian numerical models was developed. This allows real nozzles characterised during experiments to be included in the simulation, thereby correctly accounting for radial evolution of droplet size distribution and air/droplets momentum exchange. The CFD model was applied to calculate local droplet transport and evaporation, and spray cooling efficiency at different operating conditions for spray cooling systems optimisation under typical Natural Draft Dry Cooling Tower conditions. Experimental measurements from a wind tunnel test rig simulating Natural Draft Dry Cooling Tower inlet flow conditions have been performed in order to investigate droplet transport and evaporation, and spray cooling efficiency experimentally and for the CFD model validation. Based on a literature review, nine promising high pressure, hollow cone nozzles for inlet air pre-cooling were selected. Spray characterisation of the different nozzles was conducted in UQ’s wind tunnel at different atomization pressures and environmental conditions. The nozzle characterisation was performed utilizing a 2D-Phase Doppler Particle Analyser and a high speed photography system. In addition, measurements of streamwise development of droplet size and velocity, and airflow temperature and humidity were performed for different droplet sizes, velocities, injection rates, spray cone angles and spray patterns under different air velocities and ambient conditions selected to represent typical Natural Draft Dry Cooling Tower operating conditions. The wind tunnel measurements have been used for the validation of the CFD simulation model using the new more realistic hollow-cone nozzle representation approach. The simulated droplet evaporation, transport, and spray cooling efficiency were validated by comparing the predictions of the main features of the airflow and the spray (droplet axial velocity, Sauter mean droplet diameter, outlet air dry bulb temperature) with the experimental measurements downstream the nozzles at various inlet air conditions and spray characteristics. Overall, good agreement was obtained between CFD predictions and experimental measurements yielding an average deviation below 5.3% for all parameters compared. The experimental results indicated that spray dispersion is a major factor affecting nozzle and spray cooling systems performance. A modified spray cooling efficiency was introduced to separate the spray dispersion influence from the cooling efficiency. Finally, the validated CFD model has been used to identify the complex interaction between inlet air (velocity, temperature and relative humidity) and spray (droplet size, velocity, flow rate and cone angle). Two injection approaches were studied. In the first approach, droplets with a single size distribution were injected into the airflow at one single injection location in order to identify the effect of major spray characteristics parameters on droplet transport, evaporation and spray cooling efficiency. In the second approach, different droplet size distributions were injected at the breakup length using the newly developed nozzle representation. The second approach was carried out to investigate the effect of different droplet size distribution spray patterns (as observed during experiments) and major spray characteristics parameters on spray effectiveness. These simulations have provided new insight into the interactions between the spray, air flow, and cooling effectiveness. Air velocity, droplet velocity, and droplet size distribution play significant roles in droplet evaporation, transport, and spray cooling efficiency. In small size distribution, it is not always beneficial to decrease droplet size to enhance evaporation due to the compromise effect of evaporation rate and spray dispersion. However, high droplet velocities are a very effective solution that allows small droplets to penetrate deeper and distribute better within the airflow to mitigate the low Stokes number of small droplet size. Moreover, the validated CFD model has provided insight into some experimental observations (i.e. local droplet velocity increase and higher air cooling in the lower region of the duct). The study demonstrates the feasibility of utilizing spray cooling systems in natural draft dry cooling towers. Complete evaporation of water droplets emitted into airflow under NDDCTs typical condition at a hot and dry ambient condition is an achievable event but compound and trade-offs have to be made as it depends on many factors including: inlet air (velocity, temperature and relative humidity), spray (droplet size, velocity, flow rate, cone angle and configuration). The developed CFD model using the new spray initiation technique provides a good predictive design tool for spray cooling systems optimisation to enhance NDDCTs during high ambient temperature periods." @default.
- W2189698800 created "2016-06-24" @default.
- W2189698800 creator A5058968012 @default.
- W2189698800 date "2015-12-02" @default.
- W2189698800 modified "2023-09-23" @default.
- W2189698800 title "Modelling and experimental study of spray cooling systems for inlet air pre-cooling in natural draft dry cooling towers" @default.
- W2189698800 cites W1507148302 @default.
- W2189698800 cites W1578762859 @default.
- W2189698800 cites W165105818 @default.
- W2189698800 cites W1966414219 @default.
- W2189698800 cites W1967831154 @default.
- W2189698800 cites W1968036977 @default.
- W2189698800 cites W1972731318 @default.
- W2189698800 cites W1974863853 @default.
- W2189698800 cites W1975086369 @default.
- W2189698800 cites W1976358623 @default.
- W2189698800 cites W1976886884 @default.
- W2189698800 cites W1983543587 @default.
- W2189698800 cites W1987401716 @default.
- W2189698800 cites W1988844754 @default.
- W2189698800 cites W1997596883 @default.
- W2189698800 cites W1998367474 @default.
- W2189698800 cites W1999305825 @default.
- W2189698800 cites W2000434755 @default.
- W2189698800 cites W2000614977 @default.
- W2189698800 cites W2003310560 @default.
- W2189698800 cites W2003786773 @default.
- W2189698800 cites W2013990065 @default.
- W2189698800 cites W2016532617 @default.
- W2189698800 cites W2017465477 @default.
- W2189698800 cites W2020286242 @default.
- W2189698800 cites W2025183159 @default.
- W2189698800 cites W2026468961 @default.
- W2189698800 cites W2027001653 @default.
- W2189698800 cites W2030493076 @default.
- W2189698800 cites W2032903155 @default.
- W2189698800 cites W2036759815 @default.
- W2189698800 cites W2037469376 @default.
- W2189698800 cites W2040851379 @default.
- W2189698800 cites W2049335292 @default.
- W2189698800 cites W2049766861 @default.
- W2189698800 cites W2050171253 @default.
- W2189698800 cites W2050742031 @default.
- W2189698800 cites W2050807628 @default.
- W2189698800 cites W2053131341 @default.
- W2189698800 cites W2059503749 @default.
- W2189698800 cites W2060229999 @default.
- W2189698800 cites W2062708574 @default.
- W2189698800 cites W2064221303 @default.
- W2189698800 cites W2065592957 @default.
- W2189698800 cites W2066120811 @default.
- W2189698800 cites W2074360566 @default.
- W2189698800 cites W2075578512 @default.
- W2189698800 cites W2075640429 @default.
- W2189698800 cites W2078073774 @default.
- W2189698800 cites W2078355913 @default.
- W2189698800 cites W2080509875 @default.
- W2189698800 cites W2082028102 @default.
- W2189698800 cites W2082058409 @default.
- W2189698800 cites W2082601856 @default.
- W2189698800 cites W2083882813 @default.
- W2189698800 cites W2086407195 @default.
- W2189698800 cites W2090908504 @default.
- W2189698800 cites W2094257693 @default.
- W2189698800 cites W2097251732 @default.
- W2189698800 cites W2099516121 @default.
- W2189698800 cites W2100419646 @default.
- W2189698800 cites W2110223188 @default.
- W2189698800 cites W2114200336 @default.
- W2189698800 cites W2115852345 @default.
- W2189698800 cites W2119678158 @default.
- W2189698800 cites W2122396341 @default.
- W2189698800 cites W2124897046 @default.
- W2189698800 cites W2142138409 @default.
- W2189698800 cites W2157895819 @default.
- W2189698800 cites W2158484563 @default.
- W2189698800 cites W2161071819 @default.
- W2189698800 cites W2172820674 @default.
- W2189698800 cites W2274603731 @default.
- W2189698800 cites W2315214008 @default.
- W2189698800 cites W2320654445 @default.
- W2189698800 cites W2796931599 @default.
- W2189698800 cites W3148284042 @default.
- W2189698800 cites W354311966 @default.
- W2189698800 cites W46684394 @default.
- W2189698800 cites W585335255 @default.
- W2189698800 doi "https://doi.org/10.14264/uql.2015.1059" @default.
- W2189698800 hasPublicationYear "2015" @default.
- W2189698800 type Work @default.
- W2189698800 sameAs 2189698800 @default.
- W2189698800 citedByCount "2" @default.
- W2189698800 countsByYear W21896988002018 @default.
- W2189698800 countsByYear W21896988002019 @default.
- W2189698800 crossrefType "dissertation" @default.
- W2189698800 hasAuthorship W2189698800A5058968012 @default.
- W2189698800 hasBestOaLocation W21896988002 @default.
- W2189698800 hasConcept C105873366 @default.
- W2189698800 hasConcept C127413603 @default.
- W2189698800 hasConcept C153294291 @default.
- W2189698800 hasConcept C199104240 @default.