Matches in SemOpenAlex for { <https://semopenalex.org/work/W2316174749> ?p ?o ?g. }
Showing items 1 to 94 of
94
with 100 items per page.
- W2316174749 endingPage "478" @default.
- W2316174749 startingPage "475" @default.
- W2316174749 abstract "Totally implantable venous access devices (TIVADs) consist of a central venous catheter (made of silicone rubber or polyurethane) and a subcutaneously-implanted injection port made of titanium or plastic, providing a simple, safe, and permanent means of accessing the vascular system for intravenous delivery of drugs and fluids.1,2 The main advantages of these systems are to preserve peripheral vessels and to allow the patient unrestricted mobility and freedom in choice of activities.3 This situation has led to increasing use of these systems, particularly for long-term oncologic therapies.4–6 TIVADs can usually be implanted through 2 different ways: subclavian or external jugular vein puncture, by Seldinger technique, eventually under ultrasound (US) guidance; or surgical approach by vein cut-down (VCD) technique.11–14 TIVADs insertion can be accompanied by intraoperative or early postoperative severe complications, such as pneumothorax, hemothorax, arterial, or brachial plexus injuries, deep venous thrombosis and pinch-off syndrome, which seem to be more frequent in cases of direct vein puncture than during surgical approach.7–10,15–18 A recent meta-analysis showed a similar success rate and operating time, as well as complication rates, when comparing vein puncture and surgical approach, even if serious complications such as pneumothorax were higher after vein puncture.19 The authors present a comparative prospective study evaluating both VCD and US-guided Seldinger technique for TIVAD implantation, focusing on surgical outcome, intra and postoperative complications in 298 consecutive patients with a minimum follow-up of 180 days.From December 2012 to September 2013, 298 patients (161 females, 137 males, mean age) were consecutively submitted, in a day-hospital setting, to TIVAD implantation in order to perform chemotherapy for solid tumor or hematologic disease, and were prospectively evaluated. Patients were divided in 2 groups, depending on TIVAD implantation technique. Group A patients (147) received TIVAD implantation by US-guided vein puncture, and group B (151) patients received TIVAD implantation by cephalic vein cut-down (CVCD) technique. TIVAD implantations were performed by 2 different teams, who were respectively skilled in percutaneous vein puncture and in CVCD technique. Patients' demographics, neoplastic disease, and comorbidities are expressed in Table 1. All TIVADs used were BardPort (Bard Access Systems, Salt Lake City, Utah, USA), with 6.5 French polyurethane catheter. All patients received single-shot preoperative antibiotic prophylaxis 30 minutes before surgery. Comparing the 2 groups, we considered the following variables: success rate, operating time, incidence, and type of complications. Continuous data (e.g., age, operating time) were expressed as arithmetic mean +/− standard deviation, while data representing rare occurrence (such as complications) were expressed as numeric value and percentage in each group. Fisher's exact test was used for comparison between groups, considering significant a P value < 0.05.Intraoperative and postoperative results and complications are summarized in Table 2. In Group A patients, 121 TIVADs were implanted through the subclavian vein (11 left, 110 right) and 26 through the internal jugular vein (5 left, 21 right). The first approach was the subclavian vein in all cases, while the access to the internal jugular vein was obtained only in case of unsuccessful subclavian vein puncture. In 4 cases (2.7%), due to unsuccessful subclavian or internal jugular vein catheterization (despite US guidance), the catheter was inserted through external jugular vein cut-down technique. In 17 cases postoperative chest scan was performed in order to identify the presence of pneumothorax due to difficult subclavian vein puncture. In group B patients, 134 TIVADs were implanted through the cephalic (114, 24 left and 90 right) or coracobrachial (20, 3 left and 17 right) vein using the same skin incision used for the port insertion, while, in case of absence or nonsuitability of cephalic or coracobrachial vein, the catheter was inserted through the ipsilateral external jugular vein always by cut-down technique. No conversion to percutaneous vein puncture or contralateral approach, or postoperative chest scan, were needed. Mean operative time was 39.5 +/− 12.1 minutes for percutaneous vein puncture and 34.8 +/− 7.7 for vein cut-down approach, and these data showed no significant difference. Complication rate was 4.08% in Group A patients (5 cases with 2 cases of pneumothorax needing chest drain and 3 days hospitalization and 1 case of deep venous thrombosis treated with anticoagulation and subsequent TIVAD removal) and 1.98% in group B (3 cases, no pneumothorax). In 4 cases (2 of Group A, 2 of Group B), TIVAD was removed, due to wound infection, catheter tip dislocation, or deep venous thrombosis.Since the first implant described in 1982,1 TIVADs have increasingly been used for long-term intravenous nutrition and drug delivery. TIVADs achieve a permanent, safe and less painful vascular access, facilitate treatment of many medical disorders, and improve patients' quality of life by giving them unrestricted mobility and freedom in their activities.2,11 TIVADs can be implanted through either percutaneous or surgical approach.7–14 Percutaneous access consists of a direct deep vein puncture of internal jugular vein or subclavian vein (eventually axillary vein), better under US guidance, and catheter insertion using the Seldinger technique.15–17 This approach is the same used in cases of short-term central venous catheter or dialysis catheter implantation, and is still the most used worldwide.7,10,15–20 Percutaneous approach has the risks of severe intraoperative complications, such as pneumothorax, hemothorax, arterial, or brachial plexus injuries, which can affect patients' outcomes. Data in the literature show that the aforementioned complications may occur in up to 12% of patients.7,15,16,21 The use of ultrasound guidance has been demonstrated to reduce, but not to completely avoid this risk.15,22–25 On the other hand, surgical approach with peripheral vein cut-down technique (cephalic vein coracobrachial vein or even external jugular vein), which has shown an overall risk of complication similar to percutaneous approach, is obviously not affected by risk of hemothorax and pneumothorax, due to the absence of deep vein puncture.14–26 In about 10−12% of cases,13,14,18 cephalic vein is not suitable for catheterization, due to anatomic variations or vein damage. In these cases we have different options: try to identify the coracobrachial vein deeper in the Morenheim fossa or place the catheter in the ipsilateral external jugular vein. This vein is superficial, quite large, and rectilineous, and it is easy to check,14,27 placing the patient in mild Trendelenburg position. So, the combined success rate of the cephalic vein and coracobrachial/external jugular vein cut-down approach is about 100% in literature as well as in the present study.13,14,18,19,27 Results from the present prospective study show no differences in operative time, as well as mid- and long-term results between the two groups, while there was a slightly higher incidence of complications in Group A (not statistically relevant) due to specific complications of direct vein puncture.In conclusion, peripheral veins cut-down approaches for TIVAD placement are fast and safe and have a very high success rate with very low risk of complications when compared to percutaneous approach. So, this approach should be considered as a valid alternative to vein puncture approach, and the first choice in selected cases." @default.
- W2316174749 created "2016-06-24" @default.
- W2316174749 creator A5003243923 @default.
- W2316174749 creator A5018144514 @default.
- W2316174749 creator A5023483845 @default.
- W2316174749 creator A5027322561 @default.
- W2316174749 creator A5043954889 @default.
- W2316174749 creator A5057537703 @default.
- W2316174749 creator A5070132734 @default.
- W2316174749 creator A5076943659 @default.
- W2316174749 date "2014-07-01" @default.
- W2316174749 modified "2023-09-25" @default.
- W2316174749 title "Ultrasound-Guided Vein Puncture Versus Surgical Cut-Down Technique in Totally Implantable Venous Access Devices (Tivads):" @default.
- W2316174749 cites W1591396174 @default.
- W2316174749 cites W1971839041 @default.
- W2316174749 cites W1982755501 @default.
- W2316174749 cites W1997388259 @default.
- W2316174749 cites W2020347824 @default.
- W2316174749 cites W2025979799 @default.
- W2316174749 cites W2044647900 @default.
- W2316174749 cites W2047430090 @default.
- W2316174749 cites W2049253891 @default.
- W2316174749 cites W2066263176 @default.
- W2316174749 cites W2066510189 @default.
- W2316174749 cites W2068072205 @default.
- W2316174749 cites W2074037380 @default.
- W2316174749 cites W2088558878 @default.
- W2316174749 cites W2092119293 @default.
- W2316174749 cites W2102279655 @default.
- W2316174749 cites W2127827773 @default.
- W2316174749 cites W2165146587 @default.
- W2316174749 cites W2168725050 @default.
- W2316174749 cites W4237722346 @default.
- W2316174749 cites W4312285890 @default.
- W2316174749 cites W4320800312 @default.
- W2316174749 doi "https://doi.org/10.9738/intsurg-d-14-00008.1" @default.
- W2316174749 hasPubMedCentralId "https://www.ncbi.nlm.nih.gov/pmc/articles/4114383" @default.
- W2316174749 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/25058787" @default.
- W2316174749 hasPublicationYear "2014" @default.
- W2316174749 type Work @default.
- W2316174749 sameAs 2316174749 @default.
- W2316174749 citedByCount "6" @default.
- W2316174749 countsByYear W23161747492015 @default.
- W2316174749 countsByYear W23161747492017 @default.
- W2316174749 countsByYear W23161747492019 @default.
- W2316174749 countsByYear W23161747492021 @default.
- W2316174749 countsByYear W23161747492023 @default.
- W2316174749 crossrefType "journal-article" @default.
- W2316174749 hasAuthorship W2316174749A5003243923 @default.
- W2316174749 hasAuthorship W2316174749A5018144514 @default.
- W2316174749 hasAuthorship W2316174749A5023483845 @default.
- W2316174749 hasAuthorship W2316174749A5027322561 @default.
- W2316174749 hasAuthorship W2316174749A5043954889 @default.
- W2316174749 hasAuthorship W2316174749A5057537703 @default.
- W2316174749 hasAuthorship W2316174749A5070132734 @default.
- W2316174749 hasAuthorship W2316174749A5076943659 @default.
- W2316174749 hasBestOaLocation W23161747491 @default.
- W2316174749 hasConcept C126838900 @default.
- W2316174749 hasConcept C141071460 @default.
- W2316174749 hasConcept C143753070 @default.
- W2316174749 hasConcept C2777202286 @default.
- W2316174749 hasConcept C2780446839 @default.
- W2316174749 hasConcept C2781267111 @default.
- W2316174749 hasConcept C71924100 @default.
- W2316174749 hasConceptScore W2316174749C126838900 @default.
- W2316174749 hasConceptScore W2316174749C141071460 @default.
- W2316174749 hasConceptScore W2316174749C143753070 @default.
- W2316174749 hasConceptScore W2316174749C2777202286 @default.
- W2316174749 hasConceptScore W2316174749C2780446839 @default.
- W2316174749 hasConceptScore W2316174749C2781267111 @default.
- W2316174749 hasConceptScore W2316174749C71924100 @default.
- W2316174749 hasIssue "4" @default.
- W2316174749 hasLocation W23161747491 @default.
- W2316174749 hasLocation W23161747492 @default.
- W2316174749 hasLocation W23161747493 @default.
- W2316174749 hasOpenAccess W2316174749 @default.
- W2316174749 hasPrimaryLocation W23161747491 @default.
- W2316174749 hasRelatedWork W2003938723 @default.
- W2316174749 hasRelatedWork W2047967234 @default.
- W2316174749 hasRelatedWork W2118496982 @default.
- W2316174749 hasRelatedWork W2365162211 @default.
- W2316174749 hasRelatedWork W2367166131 @default.
- W2316174749 hasRelatedWork W2413090889 @default.
- W2316174749 hasRelatedWork W2439875401 @default.
- W2316174749 hasRelatedWork W4238867864 @default.
- W2316174749 hasRelatedWork W899595869 @default.
- W2316174749 hasRelatedWork W2525756941 @default.
- W2316174749 hasVolume "99" @default.
- W2316174749 isParatext "false" @default.
- W2316174749 isRetracted "false" @default.
- W2316174749 magId "2316174749" @default.
- W2316174749 workType "article" @default.