Matches in SemOpenAlex for { <https://semopenalex.org/work/W2318047572> ?p ?o ?g. }
Showing items 1 to 46 of
46
with 100 items per page.
- W2318047572 abstract "Event Abstract Back to Event In-vitro fatigue fracture of hips stems – is the ISO standard valid? Andrew Moor1, Martin H. Stone2, 3 and Todd D. Stewart1, 3 1 University of Leeds, Institute of Medical and Biological Engineering, United Kingdom 2 Chapel Alerton Hospital, Leeds Teaching Hospitals Trust, Orthopaedics, United Kingdom 3 Leeds Musculoskeletal Biomedical Research Unit, Joint Replacement Technologies, United Kingdom Introduction: One of the most important aspects of the fatigue test method outlined in ISO 7206-4 for the endurance properties of hip arthroplasty stems is the peak load applied to the femoral head. This load assumes a mean patient weight of 78 kg (applied load = 2300 N). Whilst in the past this may have been representative of the population the aim of this study was to assess current trends in patient weight and to apply these in a fatigue test to a popular hip stem as a means to assess the validity of the ISO standard companies utilise for testing. Materials and Methods: ISO fatigue testing was completed using an Instron E3000(Instron, UK) on 2 new femoral stem sizes; neither stem size had a published weight limit, all stems had a normal femoral offset. Stems were tested assuming a body weight of 90Kg and a force of 3.2 times body weight simulating walking (axial sinusoidal load ranging from 300-2800 N) with proximal loosening (incomplete coverage). 10 million cycles of ISO cyclic fatigue was completed, followed by 50 further stumbling cycles at a load of 10 times body weight applied in 0.1 seconds. Results: Under cyclic fatigue testing all components of the smaller size of the 2 stems fractured at ~30000 cycles. Components of the larger stem size did not fracture following 10 million cycles of fatigue testing. The larger stems were found to permanently deform >5mm following the aggressive stumbling cycles, however, no subsequent fractures were observed. Discussion: The weight of 90kg used in this study reflected the 75th percentile of patient weight. BMI values of THR patients commonly exceed 30 and this corresponds well with studies published in the literature. Furthermore joint reaction forces of 3.2 x body weight are representative of a hip replacement patient during normal walking[1]. All implants chosen were above the implant size range where weight limits are applied. Preclinical fatigue testing is often carried out as a part of the design process to assess the endurance performance of the prosthesis. Consequently, ISO 7206 was developed to provide an international standard for the fatigue testing of the stemmed femoral component. Part 4 of the standard simulates proximal loosening and introduces out-of-plane bending and torsion a more severe loading case. Proximal loosening has been observed clinically in a very small number of prostheses raising a potential concern, however, no clinical fractures have been reported to the authors knowledge. Conclusion: In-vitro fatigue testing of a popular femoral stem simulating proximal loosening with a 75th percentile patient weight caused fracture in all components of a smaller stem size. The results suggest that the loading conditions applied by the ISO standard should be reviewed to reflect current weight trends in patients. References:[1] Junyan Li , Anthony B. McWilliams, Zhongmin Jin, John Fisher, Martin H. Stone, Anthony C. Redmond, Todd D. Stewart. Unilateral total hip replacement patients with symptomatic leg length inequality have abnormal hip biomechanics during walking. Clinical Biomechanics, 30, pp 513–519, 2015. Keywords: in vitro, joint replacement, Implant, mechanical property Conference: 10th World Biomaterials Congress, Montréal, Canada, 17 May - 22 May, 2016. Presentation Type: Poster Topic: Mechanical properties of biomaterials Citation: Moor A, Stone MH and Stewart TD (2016). In-vitro fatigue fracture of hips stems – is the ISO standard valid?. Front. Bioeng. Biotechnol. Conference Abstract: 10th World Biomaterials Congress. doi: 10.3389/conf.FBIOE.2016.01.00656 Copyright: The abstracts in this collection have not been subject to any Frontiers peer review or checks, and are not endorsed by Frontiers. They are made available through the Frontiers publishing platform as a service to conference organizers and presenters. The copyright in the individual abstracts is owned by the author of each abstract or his/her employer unless otherwise stated. Each abstract, as well as the collection of abstracts, are published under a Creative Commons CC-BY 4.0 (attribution) licence (https://creativecommons.org/licenses/by/4.0/) and may thus be reproduced, translated, adapted and be the subject of derivative works provided the authors and Frontiers are attributed. For Frontiers’ terms and conditions please see https://www.frontiersin.org/legal/terms-and-conditions. Received: 27 Mar 2016; Published Online: 30 Mar 2016. Login Required This action requires you to be registered with Frontiers and logged in. To register or login click here. Abstract Info Abstract The Authors in Frontiers Andrew Moor Martin H Stone Todd D Stewart Google Andrew Moor Martin H Stone Todd D Stewart Google Scholar Andrew Moor Martin H Stone Todd D Stewart PubMed Andrew Moor Martin H Stone Todd D Stewart Related Article in Frontiers Google Scholar PubMed Abstract Close Back to top Javascript is disabled. Please enable Javascript in your browser settings in order to see all the content on this page." @default.
- W2318047572 created "2016-06-24" @default.
- W2318047572 creator A5021150582 @default.
- W2318047572 creator A5028581440 @default.
- W2318047572 creator A5065803090 @default.
- W2318047572 date "2016-01-01" @default.
- W2318047572 modified "2023-10-18" @default.
- W2318047572 title "In-vitro fatigue fracture of hips stems � is the ISO standard valid?" @default.
- W2318047572 doi "https://doi.org/10.3389/conf.fbioe.2016.01.00656" @default.
- W2318047572 hasPublicationYear "2016" @default.
- W2318047572 type Work @default.
- W2318047572 sameAs 2318047572 @default.
- W2318047572 citedByCount "0" @default.
- W2318047572 crossrefType "journal-article" @default.
- W2318047572 hasAuthorship W2318047572A5021150582 @default.
- W2318047572 hasAuthorship W2318047572A5028581440 @default.
- W2318047572 hasAuthorship W2318047572A5065803090 @default.
- W2318047572 hasBestOaLocation W23180475721 @default.
- W2318047572 hasConcept C126322002 @default.
- W2318047572 hasConcept C147583825 @default.
- W2318047572 hasConcept C1862650 @default.
- W2318047572 hasConcept C29694066 @default.
- W2318047572 hasConcept C71924100 @default.
- W2318047572 hasConceptScore W2318047572C126322002 @default.
- W2318047572 hasConceptScore W2318047572C147583825 @default.
- W2318047572 hasConceptScore W2318047572C1862650 @default.
- W2318047572 hasConceptScore W2318047572C29694066 @default.
- W2318047572 hasConceptScore W2318047572C71924100 @default.
- W2318047572 hasLocation W23180475721 @default.
- W2318047572 hasOpenAccess W2318047572 @default.
- W2318047572 hasPrimaryLocation W23180475721 @default.
- W2318047572 hasRelatedWork W1987392569 @default.
- W2318047572 hasRelatedWork W2101112389 @default.
- W2318047572 hasRelatedWork W2128244667 @default.
- W2318047572 hasRelatedWork W2605071393 @default.
- W2318047572 hasRelatedWork W2748952813 @default.
- W2318047572 hasRelatedWork W2803521480 @default.
- W2318047572 hasRelatedWork W2899084033 @default.
- W2318047572 hasRelatedWork W2899198113 @default.
- W2318047572 hasRelatedWork W2982110096 @default.
- W2318047572 hasRelatedWork W3031052312 @default.
- W2318047572 hasVolume "4" @default.
- W2318047572 isParatext "false" @default.
- W2318047572 isRetracted "false" @default.
- W2318047572 magId "2318047572" @default.
- W2318047572 workType "article" @default.