Matches in SemOpenAlex for { <https://semopenalex.org/work/W2318794854> ?p ?o ?g. }
Showing items 1 to 48 of
48
with 100 items per page.
- W2318794854 abstract "You have accessJournal of UrologyTrauma/Reconstruction: Trauma & Reconstructive Surgery (II)1 Apr 2013104 PENILE ENTRAPMENT BY CONSTRICTION DEVICE: A NOVEL TECHNIQUE FOR REMOVAL OF STUBBORN RINGS Daniel T. Oberlin, Puneet Masson, and Robert E. Brannigan Daniel T. OberlinDaniel T. Oberlin Chicago, IL More articles by this author , Puneet MassonPuneet Masson Chicago, IL More articles by this author , and Robert E. BranniganRobert E. Brannigan Chicago, IL More articles by this author View All Author Informationhttps://doi.org/10.1016/j.juro.2013.02.1482AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookTwitterLinked InEmail INTRODUCTION AND OBJECTIVES Penile entrapment via penile ring is an increasingly encountered clinical entity requiring urgent and effective treatment. Management poses unique challenges to the treating physician through variable presentation as well as the lack of a standardized approach to ring removal. Power-drive cutting tools, which include Dremel saws and oscillating orthopedic saws, have been utilized but have variable success and increased potential for morbidity. We present a novel technique to facilitate penile ring removal in patients presenting with this devastating condition. METHODS A retrospective single-institution study evaluating a novel strategy for penile ring removal was performed. Clinical parameters were assessed including duration of entrapment, method of entrapment, and degree of incarceration and/or tissue strangulation. Conservative attempts with manual compression and reduction of edema were initially attempted in all patients. When unsuccessful, the following steps were performed: 1) an anesthetic penile block was established with injection of 1% lidocaine at the 11 o'clock and 1 o'clock dorsal positions, 2) protection of the penile skin and reduction of penile edema by placing gauze circumferentially at the ring-skin interface, 3) insertion of the orthopedic Tungsten Carbide (T/C) pin cutter between the skin and gauze with avoidance of surrounding tissue, followed by controlled compression of cutter at 2 and 10 o'clock positions. Patients were monitored post-procedure to confirm appropriate healing and discharged home afterwards. RESULTS From 2009 to 2012, 9 patients presented with penile ring entrapment to the institution's emergency room. Manual decompression was attempted in all patients without success. All 9 patients underwent penile ring removal at the bedside using the proposed technique, with successful removal of the ring in 100% of cases. There were no complications during ring removal or evidence of tissue necrosis. All patients tolerated the procedure well and were discharged home the same day. CONCLUSIONS Penile entrapment is a urologic emergency and expeditious decompression is essential to prevent further penile injury. In situations where reduction of penile edema and removal of a constriction device are not attainable with conservative methods, there is no standardized approach to penile ring removal. This novel technique with the orthopedic pin cutter demonstrates excellent results with regards to safety and efficacy, and may be a reliable and efficient approach in the management of penile entrapment. © 2013 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 189Issue 4SApril 2013Page: e41-e42 Advertisement Copyright & Permissions© 2013 by American Urological Association Education and Research, Inc.MetricsAuthor Information Daniel T. Oberlin Chicago, IL More articles by this author Puneet Masson Chicago, IL More articles by this author Robert E. Brannigan Chicago, IL More articles by this author Expand All Advertisement Advertisement PDF downloadLoading ..." @default.
- W2318794854 created "2016-06-24" @default.
- W2318794854 creator A5017464131 @default.
- W2318794854 creator A5038439301 @default.
- W2318794854 creator A5041045531 @default.
- W2318794854 date "2013-04-01" @default.
- W2318794854 modified "2023-09-25" @default.
- W2318794854 title "104 PENILE ENTRAPMENT BY CONSTRICTION DEVICE: A NOVEL TECHNIQUE FOR REMOVAL OF STUBBORN RINGS" @default.
- W2318794854 doi "https://doi.org/10.1016/j.juro.2013.02.1482" @default.
- W2318794854 hasPublicationYear "2013" @default.
- W2318794854 type Work @default.
- W2318794854 sameAs 2318794854 @default.
- W2318794854 citedByCount "0" @default.
- W2318794854 crossrefType "journal-article" @default.
- W2318794854 hasAuthorship W2318794854A5017464131 @default.
- W2318794854 hasAuthorship W2318794854A5038439301 @default.
- W2318794854 hasAuthorship W2318794854A5041045531 @default.
- W2318794854 hasConcept C105702510 @default.
- W2318794854 hasConcept C140530291 @default.
- W2318794854 hasConcept C141071460 @default.
- W2318794854 hasConcept C2776915481 @default.
- W2318794854 hasConcept C2780149897 @default.
- W2318794854 hasConcept C71924100 @default.
- W2318794854 hasConceptScore W2318794854C105702510 @default.
- W2318794854 hasConceptScore W2318794854C140530291 @default.
- W2318794854 hasConceptScore W2318794854C141071460 @default.
- W2318794854 hasConceptScore W2318794854C2776915481 @default.
- W2318794854 hasConceptScore W2318794854C2780149897 @default.
- W2318794854 hasConceptScore W2318794854C71924100 @default.
- W2318794854 hasIssue "4S" @default.
- W2318794854 hasLocation W23187948541 @default.
- W2318794854 hasOpenAccess W2318794854 @default.
- W2318794854 hasPrimaryLocation W23187948541 @default.
- W2318794854 hasRelatedWork W2002120878 @default.
- W2318794854 hasRelatedWork W2003938723 @default.
- W2318794854 hasRelatedWork W2047967234 @default.
- W2318794854 hasRelatedWork W2118496982 @default.
- W2318794854 hasRelatedWork W2145593979 @default.
- W2318794854 hasRelatedWork W2364998975 @default.
- W2318794854 hasRelatedWork W2439875401 @default.
- W2318794854 hasRelatedWork W4238867864 @default.
- W2318794854 hasRelatedWork W4244293369 @default.
- W2318794854 hasRelatedWork W2525756941 @default.
- W2318794854 hasVolume "189" @default.
- W2318794854 isParatext "false" @default.
- W2318794854 isRetracted "false" @default.
- W2318794854 magId "2318794854" @default.
- W2318794854 workType "article" @default.