Matches in SemOpenAlex for { <https://semopenalex.org/work/W2341094588> ?p ?o ?g. }
Showing items 1 to 55 of
55
with 100 items per page.
- W2341094588 endingPage "19" @default.
- W2341094588 startingPage "19" @default.
- W2341094588 abstract "Introduction Our clinic has started to use MAZOR9s Spine-Assist(r) robotic device in routine spinal surgery practice since 2006. The use of this system is diverse and now applicable for Vertebroplasty, Biopsy procedures and different techniques of Spinal fusion. During this time our clinic performed near 150 robotic assisted surgeries. Amongst its benefits the system allows the reduction of the duration of fluoroscopic exposure in the OR, better accuracy due to computerized assisted planning and navigation, avoidance of human caused complications and a less traumatic procedure for the patient. On the other hand, the duration of the procedure is prolonged, the wound is subdued to a longer exposure in cases of the open surgery, and the operational cost is higher and requires a good trained medical staff. Materials and Methods In the last 2 years we have performed 56 robotic assisted Vertebroplasty procedures (research group). At the same time we have performed 44 non assisted Vertebroplasty procedures. There was a significant difference in the fluoroscopic time and subsequent exposure time to radiation between the groups: in the research group we used only an average of 3 seconds of staff fluoroscopic exposure (an average of 5 fluoroscopic images) compared to an average of 11 seconds of exposure (an average of 24 fluoroscopic images). Furthermore, we have successfully inserted more than 400 pedical screws with less than 1mm accuracy from planning, out which only 8 were misplaced. Subsequently we have also performed 16 biopsies, which were effective as CT based biopsies. The average duration of a surgical procedure without the use of the system in 1 level fusion was 82 min. With the use of the system the average time was 106 min. The operational cost with the use of the system was about 1,000 ∊ more expensive. Furthermore, the use of the system required performing of an additional CT scan with 1 mm slices, which caused an additional exposure to patient radiation. Results Robotic assisted spinal surgery is a new and safe approach aiming to dramatically shorten the duration of fluoroscopic exposure of the staff and surgeon thus reducing the exposure to radiogenic dose. This novel procedure, promotes a better accuracy with regard to Vertebroplasty, Spinal fusion, insertion of Pedical Screws and also for biopsies procedures. We continue to broaden the usage of the robotic assisted device to other fields of spinal surgery and to general orthopaedic surgery. However, we have to resolve some issues such as cost, operation time and less fluoroscopic exposure for the patient." @default.
- W2341094588 created "2016-06-24" @default.
- W2341094588 creator A5077552490 @default.
- W2341094588 date "2012-06-01" @default.
- W2341094588 modified "2023-09-28" @default.
- W2341094588 title "Robotic Assisted Spinal Surgery - 2 Years of Clinical Experience - Gains and Disadvantages" @default.
- W2341094588 hasPublicationYear "2012" @default.
- W2341094588 type Work @default.
- W2341094588 sameAs 2341094588 @default.
- W2341094588 citedByCount "0" @default.
- W2341094588 crossrefType "journal-article" @default.
- W2341094588 hasAuthorship W2341094588A5077552490 @default.
- W2341094588 hasConcept C126838900 @default.
- W2341094588 hasConcept C141071460 @default.
- W2341094588 hasConcept C19527891 @default.
- W2341094588 hasConcept C2776805002 @default.
- W2341094588 hasConcept C2779925993 @default.
- W2341094588 hasConcept C2989005 @default.
- W2341094588 hasConcept C71924100 @default.
- W2341094588 hasConceptScore W2341094588C126838900 @default.
- W2341094588 hasConceptScore W2341094588C141071460 @default.
- W2341094588 hasConceptScore W2341094588C19527891 @default.
- W2341094588 hasConceptScore W2341094588C2776805002 @default.
- W2341094588 hasConceptScore W2341094588C2779925993 @default.
- W2341094588 hasConceptScore W2341094588C2989005 @default.
- W2341094588 hasConceptScore W2341094588C71924100 @default.
- W2341094588 hasLocation W23410945881 @default.
- W2341094588 hasOpenAccess W2341094588 @default.
- W2341094588 hasPrimaryLocation W23410945881 @default.
- W2341094588 hasRelatedWork W195818377 @default.
- W2341094588 hasRelatedWork W2055350243 @default.
- W2341094588 hasRelatedWork W2076740251 @default.
- W2341094588 hasRelatedWork W2079581347 @default.
- W2341094588 hasRelatedWork W2132399803 @default.
- W2341094588 hasRelatedWork W2315912503 @default.
- W2341094588 hasRelatedWork W2343516623 @default.
- W2341094588 hasRelatedWork W2344108670 @default.
- W2341094588 hasRelatedWork W2402573293 @default.
- W2341094588 hasRelatedWork W2525903410 @default.
- W2341094588 hasRelatedWork W268389664 @default.
- W2341094588 hasRelatedWork W2944404836 @default.
- W2341094588 hasRelatedWork W2969227770 @default.
- W2341094588 hasRelatedWork W2970306158 @default.
- W2341094588 hasRelatedWork W2999264517 @default.
- W2341094588 hasRelatedWork W3035238844 @default.
- W2341094588 hasRelatedWork W3092214856 @default.
- W2341094588 hasRelatedWork W3119958418 @default.
- W2341094588 hasRelatedWork W3175718519 @default.
- W2341094588 hasRelatedWork W3088532881 @default.
- W2341094588 isParatext "false" @default.
- W2341094588 isRetracted "false" @default.
- W2341094588 magId "2341094588" @default.
- W2341094588 workType "article" @default.