Matches in SemOpenAlex for { <https://semopenalex.org/work/W2343156724> ?p ?o ?g. }
Showing items 1 to 63 of
63
with 100 items per page.
- W2343156724 endingPage "179" @default.
- W2343156724 startingPage "178" @default.
- W2343156724 abstract "The use of the intraosseous (IO) route for drug administration has been widely reported in the prehospital and military trauma setting, for use in paediatric patients and for use in the cardiac arrest scenario for rapid access. We wish to highlight its use for rapid sequence induction (RSI) in the adult population in a case of difficult intravenous access. A patient presented to our hospital as a stand-by call to the Emergency Department resuscitation area. He was peri-arrest with cardiogenic shock. He was cyanosed with unrecordable oxygen saturations and blood pressure but was very combative. Intubation to facilitate oxygenation was required urgently due to his rapidly deteriorating condition. Multiple attempts at securing intravenous access had been unsuccessful. An EZ-IO (Prometheus Medical Ltd, Hereford, UK) Intraosseous Vascular Access System was inserted in his right proximal tibia. Rapid sequence induction was performed using fentanyl 200mg, ketamine 100mg and suxamethonium 100mg. No fasciculations were observed. We waited 30 s and attempted direct laryngoscopy, which obtained a Grade I Cormack-Lehane View. Intubation was secured at first attempt. The induction process felt very similar in nature and speed to a standard intravenous induction. Post intubation, rapid intravenous access was secured in the right external jugular and then a femoral central line sited. The intraosseous route for drug administration has been used for many years. Studies comparing the pharmacokinetic data of intraosseous versus central venous drug delivery have primarily been undertaken in animals. One study has compared intraosseous versus intravenous rocuronium in anaesthetised swine. They compared electromyographic data obtained following tibial intraosseous administration to that of peripheral intravenous administration and demonstrated no statistically significant difference in the onset time between the two groups. They also demonstrated that the duration of paralysis with the intraosseous route was longer than with the intravenous. They concluded that rocuronium could be administered via the intraosseous route in the same doses as when using the intravenous route. With regard to human studies, a prospective, randomised crossover study has compared the delivery of intraosseous to intravenous morphine in adults and demonstrated that there was no statistically significant difference in the majority of the pharmacokinetic data including the maximum plasma concentration, time to maximum concentration and area under plasma concentration time curve. The majority of reports of using intraosseous for RSI have come from military and trauma experience. A recent observational study has been published in the Emergency Medicine Journal looking at whether RSI via IO was comparable to the intravenous route in terms of grade of view and number of attempts at intubation. The study demonstrated that in the 34 patients who received RSI via IO for trauma they had a 97% first pass intubation rate and that 91% of patients had a Grade 1 Cormack-Lehane view. They were unable to compare this directly to RSI via the intravenous route, as intraosseous access is often the preferred route of access in a military trauma setting. A further military study retrospectively reviewed 830 adult trauma cases and found that 1014 IO devices were inserted over a 60-month period. They demonstrated that the devices were used to infuse anaesthetic induction drugs, analgesia, tranexamic acid, blood and blood products, and intravenous fluids. Of the 1205 times that the IO route was used to infuse drugs, anaesthetic induction agents were the most common drug given, being used for this purpose in 61.8% of cases. With regard to complications, there were no serious complications reported and 14 minor complications that included failure to correctly place IO device, failure to infuse drug, or fracture of needle. This is similar to a Danish study that looked at complications associated with intraosseous access. They showed that serious complications such as compartment syndrome or osetomyelitis are very rare and that problems such as difficulty penetrating periosteum, difficulty aspirating bone marrow and difficulties injecting or infusing fluids or drugs are more common. One of the concerns with the use of the intraosseous route in awake patients is the side effects of pain on insertion and pain on injection. Reports have" @default.
- W2343156724 created "2016-06-24" @default.
- W2343156724 creator A5041329083 @default.
- W2343156724 creator A5077227887 @default.
- W2343156724 date "2016-05-01" @default.
- W2343156724 modified "2023-09-24" @default.
- W2343156724 title "Rapid sequence induction via an intraosseous needle" @default.
- W2343156724 cites W1978601077 @default.
- W2343156724 cites W1991019177 @default.
- W2343156724 cites W2044764378 @default.
- W2343156724 cites W2086241433 @default.
- W2343156724 cites W2095241412 @default.
- W2343156724 cites W2170700001 @default.
- W2343156724 doi "https://doi.org/10.1177/1751143715614845" @default.
- W2343156724 hasPubMedCentralId "https://www.ncbi.nlm.nih.gov/pmc/articles/5606396" @default.
- W2343156724 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/28979485" @default.
- W2343156724 hasPublicationYear "2016" @default.
- W2343156724 type Work @default.
- W2343156724 sameAs 2343156724 @default.
- W2343156724 citedByCount "1" @default.
- W2343156724 countsByYear W23431567242023 @default.
- W2343156724 crossrefType "journal-article" @default.
- W2343156724 hasAuthorship W2343156724A5041329083 @default.
- W2343156724 hasAuthorship W2343156724A5077227887 @default.
- W2343156724 hasBestOaLocation W23431567241 @default.
- W2343156724 hasConcept C141071460 @default.
- W2343156724 hasConcept C2778112365 @default.
- W2343156724 hasConcept C2778716859 @default.
- W2343156724 hasConcept C2778801495 @default.
- W2343156724 hasConcept C54355233 @default.
- W2343156724 hasConcept C71924100 @default.
- W2343156724 hasConcept C86803240 @default.
- W2343156724 hasConceptScore W2343156724C141071460 @default.
- W2343156724 hasConceptScore W2343156724C2778112365 @default.
- W2343156724 hasConceptScore W2343156724C2778716859 @default.
- W2343156724 hasConceptScore W2343156724C2778801495 @default.
- W2343156724 hasConceptScore W2343156724C54355233 @default.
- W2343156724 hasConceptScore W2343156724C71924100 @default.
- W2343156724 hasConceptScore W2343156724C86803240 @default.
- W2343156724 hasIssue "2" @default.
- W2343156724 hasLocation W23431567241 @default.
- W2343156724 hasLocation W23431567242 @default.
- W2343156724 hasLocation W23431567243 @default.
- W2343156724 hasLocation W23431567244 @default.
- W2343156724 hasOpenAccess W2343156724 @default.
- W2343156724 hasPrimaryLocation W23431567241 @default.
- W2343156724 hasRelatedWork W2002120878 @default.
- W2343156724 hasRelatedWork W2003938723 @default.
- W2343156724 hasRelatedWork W2047967234 @default.
- W2343156724 hasRelatedWork W2118496982 @default.
- W2343156724 hasRelatedWork W2364998975 @default.
- W2343156724 hasRelatedWork W2369162477 @default.
- W2343156724 hasRelatedWork W2439875401 @default.
- W2343156724 hasRelatedWork W4238867864 @default.
- W2343156724 hasRelatedWork W2519357708 @default.
- W2343156724 hasRelatedWork W2525756941 @default.
- W2343156724 hasVolume "17" @default.
- W2343156724 isParatext "false" @default.
- W2343156724 isRetracted "false" @default.
- W2343156724 magId "2343156724" @default.
- W2343156724 workType "article" @default.