- W2529788666 abstract "Tabled 1KEY TEACHING POINTS•The complication rate for catheter ablation of atrial fibrillation is 4%–6%. A catheter becoming entrapped in the heart is a very rare complication.•The main sites of catheter entrapment in a heart are the mitral valve and the Chiari apparatus. An ablation catheter could be entrapped by the small branch of the pulmonary vein when the diameter of the ostium of the small branch coincidentally equals the size of the catheter tip.•Starting to monitor the contact force immediately after insertion of the catheter into the intracardiac chamber and confirming the catheter location by the biplane image might prevent this complication. Open table in a new tab A catheter entrapment in the heart is a very rare complication. Most case reports on entrapment have described ring catheters becoming entrapped. An ablation catheter becoming entrapped has rarely been reported. A 64-year-old woman with a 3-year history of drug refractory paroxysmal atrial fibrillation was referred to our hospital for catheter ablation. Preprocedual echocardiography and enhanced computed tomography (CT) revealed no structural heart disease or anatomic anomalies (Figure 1A). Catheter ablation of the atrial fibrillation was performed under conscious sedation. Two 8.5-F long sheaths, an 8-F long sheath, and a 6-F short sheath were introduced percutaneously via the right femoral vein. A 6-F venous sheath was introduced via the right internal jugular vein. A decapolar electrode catheter was positioned in the right ventricular apex. A duodecapolar electrode catheter was advanced into the coronary sinus. A transseptal puncture was performed with the assistance of intracardiac echocardiography using a radiofrequency needle (Japan Lifeline, Tokyo, Japan). Three long sheaths were advanced into the left atrium through the same puncture site. Pulmonary vein (PV) and left atrial angiogram revealed no anatomic anomalies, and the sheaths were placed into the superior PVs. Two circular mapping catheters were positioned in the PVs. An ablation catheter (Thermocool Smart Touch, Biosense Webster, Diamond Bar, CA) was inserted into the 8.5-F sheath placed in the right superior PV. The ablation catheter was pulled back and moved to start the ablation. The operator intended to place the ablation catheter into the left PV and pushed the catheter rightward (patient’s left side) in the left anterior oblique view. At that point, the catheter became entrapped. Intracardiac echocardiography showed that the ablation catheter shaft was in the left atrium; however, the location of the catheter tip was unclear. Gentle traction only produced a shift in the atrial wall. When the sheath was advanced, the ablation catheter could be inserted into the sheath. However, the catheter tip would not come free from the PV (Figure 2A–C). Rotational traction also was not effective. Then, the patient was transferred for a CT scan. The CT results showed that the catheter tip was positioned in a small branch of the PV or extracardiac area (Figure 1B). Strong traction could injure the cardiac tissue; therefore, a surgical removal and Maze procedure were performed after informed consent was received from the patient. According to the intraoperative findings, the catheter was entrapped in a small branch of the right inferior PV (RIPV) (Figure 3). It could not be removed even by traction during direct observation. A microincision in the branch released the catheter, and the small branch was sutured. A Maze procedure and left atrial appendage closure were performed. Subsequent analysis of CT results revealed that the root of the small branch separated from the right inferior PV ostium could be recognized; however, the tip of the branch was not visualized (Figure 1A). The diameter of the small branch was 2.5 mm. The patient was discharged 19 days after the operation. She has had no recurrences of atrial fibrillation.Figure 2Fluoroscopic image of the catheters. A: The ablation catheter entrapment site. B: The ablation catheter was pulled and inserted into the sheath. C: The ablation catheter and sheath were pulled to the maximum. These figures indicate the catheter had mobility of about 20 mm even after the catheter became entrapped.View Large Image Figure ViewerDownload Hi-res image Download (PPT)Figure 3A photograph taken during the surgery, from the head of the patient. The lower side is cranial and the upper side is caudal. Two suction tubes were in the right superior pulmonary vein (PV) and right inferior PV, respectively. The ablation catheter was entrapped in a small branch of the right inferior PV. The catheter tip was placed 15 mm distal to the RIPV ostium.View Large Image Figure ViewerDownload Hi-res image Download (PPT) Our case involved a rare complication with an ablation catheter getting entrapped in the RIPV and requiring open heart surgery. The complication rate for catheter ablation of atrial fibrillation is 4-6%.1Cappato R. Calkins H. Chen S.A. et al.Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation.Circ Arrhythm Electrophysiol. 2010; 3: 32-38Crossref PubMed Scopus (1561) Google Scholar, 2Shah R.U. Freeman J.V. Shilane D. Wang P.J. Go A.S. Hlatky M.A. Procedural complications, rehospitalizations, and repeat procedures after catheter ablation for atrial fibrillation.J Am Coll Cardiol. 2012; 59: 143-149Abstract Full Text Full Text PDF PubMed Scopus (219) Google Scholar, 3Inoue K. Murakawa Y. Nogami A. Shoda M. Naito S. Kumagai K. Miyauchi Y. Yamane T. Morita N. Okumura K. Japanese Heart Rhythm Society MembersCurrent status of catheter ablation for atrial fibrillation—updated summary of the Japanese Catheter Ablation Registry of Atrial Fibrillation (J-CARAF).Circ J. 2014; 78: 1112-1120Crossref Scopus (30) Google Scholar A catheter becoming entrapped in heart is a very rare complication, and that of an ablation catheter becoming entrapped has rarely been reported. Most case reports of entrapment have described ring catheters becoming entrapped. Of the total of 8 case reports on a ring catheter becoming entrapped in the mitral apparatus, open heart surgery was required in all cases.4Je H.G. Kim J.W. Jung S.H. Lee J.W. Minimally invasive surgical release of entrapped mapping catheter in the mitral valve.Circ J. 2008; 72: 1378-1380Crossref PubMed Scopus (10) Google Scholar, 5Zeljko H.M. Mont L. Sitges M. Tolosana J.M. Nadal M. Castella M. Brugada J. Entrapment of the circular mapping catheter in the mitral valve in two patients undergoing atrial fibrillation ablation.Europace. 2011; 13: 132-133Crossref PubMed Scopus (13) Google Scholar, 6Weymann A. Schmack B. Rauch H. Rosendal C. Karck M. Szabó G. Entanglement of a circular mapping catheter in the mitral valve with persistent iatrogenic atrial septal defect after attempted pulmonary vein isolation: a word of caution.Ann Thorac Cardiovasc Surg. 2014; 20: 250-252Crossref PubMed Scopus (2) Google Scholar The Chiari apparatus is also an important structure that requires careful attention. There was 1 case report about a duodecapolar catheter entrapment in the Chiari apparatus that required vascular surgery for its removal.7Grecu M. Floria M. Tinică G. Complication due to entrapment in the Chiari apparatus.Europace. 2014; 16: 577Crossref Scopus (4) Google Scholar Rarely are PVs anatomic structures that cause catheter entrapment. There has been only 1 previous case report about an ablation catheter becoming entrapped in a PV. Stronger traction and rotation with unusual resistance could release the ablation catheter. However, the catheter tip was covered with the translucent membrane of the venous branch.8Monney P. Pascale P. Fromer M. Pruvot E. Catheter entrapment in a pulmonary vein a unique complication of pulmonary vein isolation.Chest. 2010; 138: 422-425Crossref Scopus (5) Google Scholar This maneuver has the risk of a major hemorrhage. Open heart surgery may be safer when normal traction is not effective. The PVs have a tapered shape and therefore are associated with the potential risk for catheter entrapment. However, the diameter of the PV branch becomes the same as the diameter of the catheter tip only in the distal portion. The ablation catheter is not usually inserted into the terminal portion of the branch. It was confirmed during the open heart surgery that the diameter of the ostium of the small branch coincidentally equaled the size of the ablation catheter tip. The diameter of the small branch was 2.5 mm. The RIPV has a tendency to branch early near its root.9Mansour M. Holmvang G. Sosnovik D. Migrino R. Abbara S. Ruskin J. Keane D. Assessment of pulmonary vein anatomic variability by magnetic resonance imaging: implications for catheter ablation techniques for atrial fibrillation.J Cardiovasc Electrophysiol. 2004; 15: 387-393Crossref PubMed Scopus (160) Google Scholar In such a case, it is difficult for the operator to recognize whether the catheter is positioned in the left atrium or PV branch. In this case, a small branch separated from the right inferior PV ostium. However, the 3-dimensional constructed CT could visualize only the root of the small branch (Figure 1A). Therefore, the operator could not recognize the small branch before the procedure, and as a result, the catheter was forcefully inserted into the PV branch unintentionally. The PV branch was stretchier than the left atrial wall even after the catheter entrapment. The catheter was still mobile within about 20 mm (Figure 2A–C). This retractility prevented the operator from recognizing the catheter insertion into the small branch. The ablation catheter used in this case had a contact force sensor. However, the catheter was entrapped before we began to monitor the contact force. We should have started to monitor the contact force immediately after the catheter was inserted into the intracardiac chamber. The operator saw only the left anterior oblique view in fluoroscopy. Confirming the catheter location by the biplane image might prevent this complication. Our case involved a very rare complication with an ablation catheter getting entrapped in the RIPV and requiring open heart surgery. Gentle catheter manipulation is required at all times." @default.
- W2529788666 created "2016-10-14" @default.
- W2529788666 creator A5016164244 @default.
- W2529788666 creator A5021118252 @default.
- W2529788666 creator A5022209091 @default.
- W2529788666 creator A5024604439 @default.
- W2529788666 creator A5025720985 @default.
- W2529788666 creator A5043132510 @default.
- W2529788666 creator A5043266159 @default.
- W2529788666 creator A5067063901 @default.
- W2529788666 creator A5074865701 @default.
- W2529788666 creator A5075305875 @default.
- W2529788666 creator A5089456844 @default.
- W2529788666 creator A5091274314 @default.
- W2529788666 date "2017-01-01" @default.
- W2529788666 modified "2023-09-30" @default.
- W2529788666 title "A case of an ablation catheter entrapped in the pulmonary vein during atrial fibrillation ablation requiring open heart surgery for removal" @default.
- W2529788666 cites W1994312044 @default.
- W2529788666 cites W2008635984 @default.
- W2529788666 cites W2034343222 @default.
- W2529788666 cites W2052339069 @default.
- W2529788666 cites W2066065996 @default.
- W2529788666 cites W2119278267 @default.
- W2529788666 cites W2120316478 @default.
- W2529788666 cites W2146673314 @default.
- W2529788666 cites W2333761865 @default.
- W2529788666 doi "https://doi.org/10.1016/j.hrcr.2016.09.008" @default.
- W2529788666 hasPubMedCentralId "https://www.ncbi.nlm.nih.gov/pmc/articles/5420032" @default.
- W2529788666 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/28491775" @default.
- W2529788666 hasPublicationYear "2017" @default.
- W2529788666 type Work @default.
- W2529788666 sameAs 2529788666 @default.
- W2529788666 citedByCount "2" @default.
- W2529788666 countsByYear W25297886662018 @default.
- W2529788666 countsByYear W25297886662020 @default.
- W2529788666 crossrefType "journal-article" @default.
- W2529788666 hasAuthorship W2529788666A5016164244 @default.
- W2529788666 hasAuthorship W2529788666A5021118252 @default.
- W2529788666 hasAuthorship W2529788666A5022209091 @default.
- W2529788666 hasAuthorship W2529788666A5024604439 @default.
- W2529788666 hasAuthorship W2529788666A5025720985 @default.
- W2529788666 hasAuthorship W2529788666A5043132510 @default.
- W2529788666 hasAuthorship W2529788666A5043266159 @default.
- W2529788666 hasAuthorship W2529788666A5067063901 @default.
- W2529788666 hasAuthorship W2529788666A5074865701 @default.
- W2529788666 hasAuthorship W2529788666A5075305875 @default.
- W2529788666 hasAuthorship W2529788666A5089456844 @default.
- W2529788666 hasAuthorship W2529788666A5091274314 @default.
- W2529788666 hasBestOaLocation W25297886661 @default.
- W2529788666 hasConcept C126322002 @default.
- W2529788666 hasConcept C141071460 @default.
- W2529788666 hasConcept C164705383 @default.
- W2529788666 hasConcept C2776131983 @default.
- W2529788666 hasConcept C2777611987 @default.
- W2529788666 hasConcept C2778902805 @default.
- W2529788666 hasConcept C2779161974 @default.
- W2529788666 hasConcept C2780689522 @default.
- W2529788666 hasConcept C2781267111 @default.
- W2529788666 hasConcept C71924100 @default.
- W2529788666 hasConceptScore W2529788666C126322002 @default.
- W2529788666 hasConceptScore W2529788666C141071460 @default.
- W2529788666 hasConceptScore W2529788666C164705383 @default.
- W2529788666 hasConceptScore W2529788666C2776131983 @default.
- W2529788666 hasConceptScore W2529788666C2777611987 @default.
- W2529788666 hasConceptScore W2529788666C2778902805 @default.
- W2529788666 hasConceptScore W2529788666C2779161974 @default.
- W2529788666 hasConceptScore W2529788666C2780689522 @default.
- W2529788666 hasConceptScore W2529788666C2781267111 @default.
- W2529788666 hasConceptScore W2529788666C71924100 @default.
- W2529788666 hasIssue "1" @default.
- W2529788666 hasLocation W25297886661 @default.
- W2529788666 hasLocation W25297886662 @default.
- W2529788666 hasLocation W25297886663 @default.
- W2529788666 hasLocation W25297886664 @default.
- W2529788666 hasOpenAccess W2529788666 @default.
- W2529788666 hasPrimaryLocation W25297886661 @default.
- W2529788666 hasRelatedWork W1201797503 @default.
- W2529788666 hasRelatedWork W1971108666 @default.
- W2529788666 hasRelatedWork W2021493629 @default.
- W2529788666 hasRelatedWork W2034156327 @default.
- W2529788666 hasRelatedWork W2094486097 @default.
- W2529788666 hasRelatedWork W2334172342 @default.
- W2529788666 hasRelatedWork W2359227379 @default.
- W2529788666 hasRelatedWork W2583047656 @default.
- W2529788666 hasRelatedWork W2997443537 @default.
- W2529788666 hasRelatedWork W3206627070 @default.
- W2529788666 hasVolume "3" @default.
- W2529788666 isParatext "false" @default.
- W2529788666 isRetracted "false" @default.
- W2529788666 magId "2529788666" @default.
- W2529788666 workType "article" @default.