Matches in SemOpenAlex for { <https://semopenalex.org/work/W2530622066> ?p ?o ?g. }
Showing items 1 to 71 of
71
with 100 items per page.
- W2530622066 endingPage "07" @default.
- W2530622066 startingPage "01" @default.
- W2530622066 abstract "Introduction: Traditional open surgeries are now being done by minimally invasive keyhole laparoscopic techniques. Simultaneously, airway management of patients has also progressed from ventilation through endotracheal tube to lesser invasive Laryngeal Mask Airway. The Proseal Laryngeal Mask Airway, the latest in the family of Laryngeal Mask Airway, differs from the standard Laryngeal Mask Airway in having a drain tube in addition to a reinforced airway tube. It is a highly satisfactory device in securing an airway, it's lacunae with positive pressure ventilation (PPV), especially in patients with decreased pulmonary compliance prompted him further to find a better airway device.It also offered protection against regurgitation and gastric insufflation. AIMS And Objective: The present study aims to compare safety and efficacy of giving general anesthesia using proseal laryngeal mask airway in patients undergoing laproscopic surgery. The above will be reached by observing vital parameters – heart rate, blood pressure , oxygen saturation , end tidal carbon di-oxide level & any other complications as observed . Material And Methods: The proposed study was carried out in S.R.N. Hospital associated with M.L.N. Medical College , Allahabad. After randomization & blinding, patients will be allocated in one of the following groups. each group containing 30 patients. Group A: Undergoing general anaesthesia using Proseal laryngeal mask Airway(PLMA). Group B: Undergoing general anaesthesia using Endotracheal tube(ETT). Results:Compared to PLMA group , patient that were intubated with E.T. tube showed significantly increase in Pulse rate, SBP, DBP & MAP which was statistically significant till 5 th min of induction(p value <0.0001) & immediate postoperative period.Postoperative there was significant increase in incidence of sorethroat in ETT group. Conclusion: The comparative study showed PLMA has good hemodynamic stability, adequate ventilation and less post-operative airway complication. Hence, it is concluded PLMA is suiFigure and a safe alternative to cuffed ETT for airway management in elective non obese patients undergoing laparoscopic surgeries under general anaesthesia" @default.
- W2530622066 created "2016-10-21" @default.
- W2530622066 creator A5016621307 @default.
- W2530622066 creator A5024639326 @default.
- W2530622066 creator A5040559146 @default.
- W2530622066 creator A5072591106 @default.
- W2530622066 creator A5090449363 @default.
- W2530622066 date "2016-09-01" @default.
- W2530622066 modified "2023-10-16" @default.
- W2530622066 title "“A Comparison of General Anaesthesia Techinques Using Proseal Laryngeal Mask Airway Or Endotracheal Tube, In Patients Undergoing Laproscopic Surgery”." @default.
- W2530622066 cites W140044211 @default.
- W2530622066 cites W1485283641 @default.
- W2530622066 cites W1971485701 @default.
- W2530622066 cites W1997931589 @default.
- W2530622066 cites W2007659371 @default.
- W2530622066 cites W2150878484 @default.
- W2530622066 cites W2170129995 @default.
- W2530622066 cites W2170524179 @default.
- W2530622066 cites W2462188333 @default.
- W2530622066 cites W2464718069 @default.
- W2530622066 cites W2472179389 @default.
- W2530622066 cites W2921658548 @default.
- W2530622066 doi "https://doi.org/10.9790/0853-1509130107" @default.
- W2530622066 hasPublicationYear "2016" @default.
- W2530622066 type Work @default.
- W2530622066 sameAs 2530622066 @default.
- W2530622066 citedByCount "0" @default.
- W2530622066 crossrefType "journal-article" @default.
- W2530622066 hasAuthorship W2530622066A5016621307 @default.
- W2530622066 hasAuthorship W2530622066A5024639326 @default.
- W2530622066 hasAuthorship W2530622066A5040559146 @default.
- W2530622066 hasAuthorship W2530622066A5072591106 @default.
- W2530622066 hasAuthorship W2530622066A5090449363 @default.
- W2530622066 hasBestOaLocation W25306220661 @default.
- W2530622066 hasConcept C105922876 @default.
- W2530622066 hasConcept C141071460 @default.
- W2530622066 hasConcept C2776900724 @default.
- W2530622066 hasConcept C2776983577 @default.
- W2530622066 hasConcept C2778716859 @default.
- W2530622066 hasConcept C3019038464 @default.
- W2530622066 hasConcept C42219234 @default.
- W2530622066 hasConcept C71924100 @default.
- W2530622066 hasConceptScore W2530622066C105922876 @default.
- W2530622066 hasConceptScore W2530622066C141071460 @default.
- W2530622066 hasConceptScore W2530622066C2776900724 @default.
- W2530622066 hasConceptScore W2530622066C2776983577 @default.
- W2530622066 hasConceptScore W2530622066C2778716859 @default.
- W2530622066 hasConceptScore W2530622066C3019038464 @default.
- W2530622066 hasConceptScore W2530622066C42219234 @default.
- W2530622066 hasConceptScore W2530622066C71924100 @default.
- W2530622066 hasIssue "09" @default.
- W2530622066 hasLocation W25306220661 @default.
- W2530622066 hasOpenAccess W2530622066 @default.
- W2530622066 hasPrimaryLocation W25306220661 @default.
- W2530622066 hasRelatedWork W1555572994 @default.
- W2530622066 hasRelatedWork W1898277211 @default.
- W2530622066 hasRelatedWork W2040236441 @default.
- W2530622066 hasRelatedWork W2055857700 @default.
- W2530622066 hasRelatedWork W2106443424 @default.
- W2530622066 hasRelatedWork W2169179843 @default.
- W2530622066 hasRelatedWork W2344295942 @default.
- W2530622066 hasRelatedWork W2979710695 @default.
- W2530622066 hasRelatedWork W590157893 @default.
- W2530622066 hasRelatedWork W2111116368 @default.
- W2530622066 hasVolume "15" @default.
- W2530622066 isParatext "false" @default.
- W2530622066 isRetracted "false" @default.
- W2530622066 magId "2530622066" @default.
- W2530622066 workType "article" @default.