Matches in SemOpenAlex for { <https://semopenalex.org/work/W2569795900> ?p ?o ?g. }
Showing items 1 to 84 of
84
with 100 items per page.
- W2569795900 endingPage "794" @default.
- W2569795900 startingPage "791" @default.
- W2569795900 abstract "The use of MRI in radiotherapy planning and simulation is increasing rapidly and is beginning to be integrated into the external beam radiation therapy (EBRT) treatment process. Some have suggested that integrated MRI-linac systems, not the standalone MRI-Sim, represents the future of MRI in radiotherapy, and this is the claim debated in this month's Point/Counterpoint. Arguing for the Proposition is Vladimir Feygelman, Ph.D. Dr. Feygelman received his 5-year (M.S.-equivalent) degree in Laser Physics in 1982 and his Ph.D. in Physical Chemistry in 1985, both from the Rostov State University in the former USSR. Upon landing in the US, he discovered the profession of Medical Physics and, after on the job training, became ABR-certified in Therapeutic Radiological Physics in 1995. Since then, he has held both purely clinical and research-oriented positions and, currently, is an Associate Member faculty physicist at Moffitt Cancer Center in Tampa, FL, USA. He is a member of the team charged with evaluating and implementing new technologies for the Radiation Oncology Department. Dr. Feygelman's current research interests center primarily around quality assurance equipment and procedures for advanced treatments, and he has over 60 peer-reviewed publications. He serves on several AAPM committees and task groups, and is an Associate Editor of both Medical Physics and the JACMP. Arguing against the Proposition is Frank Lohr, M.D. Dr. Lohr received his medical degree from Heidelberg University, Germany, followed by a residency in the Department of Radiation Oncology of Heidelberg University and the German Cancer Research Center, Heidelberg. During residency, he spent 2 years in radiobiological research on hyperthermia-induced gene therapy at Duke University, NC. Following his residency, he joined the team at the Department of Radiation Oncology at University Medical Center Mannheim, University of Heidelberg, as an attending physician, where he became the vice chairman in 2004 and the associate adjunct professor in 2005. Recently, he moved to his current position as the Director of Radiotherapy at the University Hospital, Modena, Italy. He is specially interested in precision radiotherapy techniques such as IMRT, VMAT (performed the second VMAT treatment in Germany), IGRT, and SBRT. His main clinical and research interests are lung, gastric, H&N, CNS and prostate cancers, interdisciplinary optimization of surgery, systemic therapy (particularly immunotherapy), and radiotherapy, as well as the optimization of local radiotherapy based on optimal integration of imaging modalities such as MRI (e.g., iron oxide nanoparticles) and PET. Dr. Lohr has contributed to more than 130 peer-reviewed scientific articles, textbook chapters and textbooks, and is co-editor of a German standard radiotherapy textbook. There is no argument about the increasingly important role of MRI in radiation oncology.1-3 We disagree only on what is the best approach to even tighter integration of MRI into the radiotherapy process. In order to argue that the integrated MR-guided radiation therapy (IMGRT) system is, on balance, the optimal solution, all one has to do is to compare suitability and necessity of IMGRT vs. MR-Simulator (MRS) for the following list of tasks pertinent to radiation oncology. To summarize, in every conceivable clinical or research category, IMGRT capabilities are either superior to, or on par with the MRS. Right now and in the foreseeable future, it is an ultimate SBRT tool, “making radiotherapy more of an interventional radiology process”, as was elegantly stated by Lagendijk et al.1 IMGRT combines immediately available, neatly integrated motion management and daily dose adaptation capabilities with future research experience in functional imaging, which is way more than can be plausibly speculated about the MRS standalone system. There is no doubt that the ideal situation for radiotherapy would be a treatment under more or less static conditions in an ideal dosimetric situation with permanent online image-based control of the position of tumor, OARs, and patient surface. Online MR-guidance is therefore an appealing concept and it has already been applied to brachytherapy.9 However, to provide clinical results beyond what current image guidance strategies in external beam radiotherapy can achieve, several requirements must be fulfilled on the way, and the allocation of a large amount of resources has to be justified. We have already come very close to the objective of treating a quasi-static geometric situation if advanced image guidance strategies already available at moderate cost are fully used. Several such strategies are now available but are underutilized, typically for lack of funding or perceived complexity. Recent developments, such as flattening-filter-free (FFF)-delivery and fast collimators have, however, dramatically shortened treatment time and thus rendered advanced imaging strategies more feasible. Considerable expertise is needed, as it is also for MR-guidance. Continuous 2D-tracking based on fiducials placed by minimally invasive procedures has entered the clinical routine for the ablation of small lesions without complex interference of OARs and achieved precision is near-perfect.10 3D-imaging with CBCT, particularly in conjunction with breath-hold strategies,11 still has considerable potential. Accuracies in the range of 3 mm can be consistently achieved across treatment targets using deep inspiration breath-hold, resulting in favorable dose distributions and straightforward dose accumulation. 4D-approaches are available, and ultrafast “snapshot” volume imaging is ready to be deployed clinically.12 Ultrasound, where applicable, allows not only for positioning but also for tracking in 2D and 3D.13 Surface scanning as a complementary positioning and gating tool not using ionizing radiation may simultaneously provide patient surveillance and gating signals during a therapy session, further improving overall precision of a treatment.14 The integration of functional MR-data into the treatment process is desirable, but the possibilities at the currently available field strengths in integrated machines are limited. Another aspect is that non-coplanar treatment strategies have recently gained renewed interest outside the cranial area15 and high-LET radiation, too, may have further potential to improve clinical results independent of imaging strategy. Both strategies are currently not feasible in conjunction with in-room MR-guidance. Finally, local control of small, mobile lesions is already excellent. For larger lesions, overcoming integral dose limits using particle strategies may be more important than minimally further improving geometric precision. In conclusion, if online MR-guidance is necessary, then there is a general necessity for broad use of advanced image guidance strategies, particularly as successful screening programs such as those for lung cancer and, potentially, even pancreatic cancer, are established, as this potentially leads to more localized disease being treated. These opportunities should be exploited immediately with available technology while, in parallel, online MR-guidance is scientifically developed to provide added value in applications such as intratumoral dose painting, conformal treatment of individual lymph nodes identified as positive by novel markers, or other situations not yet identified that go beyond just providing geographic precision. My distinguished opponent has chosen to shift the debate away from the relative merits of IMGRT vs. MRS. It is understandable, given the paucity of reported clinical accomplishments of MRS in the last 15 years. Instead, the strategy of the opposing Opening Statement is to enumerate different existing IGRT approaches, with the aim of convincing the reader that IMGRT is an unnecessary luxury. In reality, each one of those techniques comes with a sizable disclaimer. Some only work for certain disease sites. Others require implanted fiducials or rely on external surrogates, and/or provide no information beyond (hopefully) tumor location. My opponent and his co-authors seem to advocate that breath-hold is the ultimate answer to the problem of motion in radiotherapy and are willing to resort to extraordinary measures to induce prolonged breath-holds beyond normal physiology.16 However, in the same breath the authors “emphasize the urgent need for more research on the position changes of both tumors and healthy tissue throughout breath-holding.” This in itself contradicts my opponent's main postulate that the current image guidance strategies have already achieved the saturation point of clinical impact. To further dispel that assertion, early reports from the clinical IMGRT sites, admittedly anecdotal so far, indicate that there may be a subgroup of patients, previously considered untreatable, that can now be offered beneficial radiotherapy. Unlike the other IGRT techniques, IMGRT is universally applicable to any disease site and provides direct visualization, with best image quality currently available, of the tumor and surrounding OARs, for both adaptive re-planning and real-time motion management. While the cost of an MR-guided system currently is roughly double that of the nicely equipped accelerator, once one adds up the costs of separate IGRT systems best suited for every clinical situation, the cost gap narrows appreciably, yet without matching the image quality and seamless workflow of IMGRT. The authors have no relevant conflicts of interest to disclose." @default.
- W2569795900 created "2017-01-13" @default.
- W2569795900 creator A5026442912 @default.
- W2569795900 creator A5073682650 @default.
- W2569795900 creator A5089476321 @default.
- W2569795900 date "2017-02-13" @default.
- W2569795900 modified "2023-10-06" @default.
- W2569795900 title "The future of MRI in radiation therapy belongs to integrated MRI-linac systems, not the standalone MRI-Sim" @default.
- W2569795900 cites W1988811616 @default.
- W2569795900 cites W1989985079 @default.
- W2569795900 cites W2000946074 @default.
- W2569795900 cites W2033929819 @default.
- W2569795900 cites W2042262831 @default.
- W2569795900 cites W2070935120 @default.
- W2569795900 cites W2115173250 @default.
- W2569795900 cites W2133880976 @default.
- W2569795900 cites W2163533828 @default.
- W2569795900 cites W2166273484 @default.
- W2569795900 cites W2255290178 @default.
- W2569795900 cites W2287904894 @default.
- W2569795900 cites W2308751262 @default.
- W2569795900 cites W2345333796 @default.
- W2569795900 cites W2474839153 @default.
- W2569795900 cites W585341442 @default.
- W2569795900 doi "https://doi.org/10.1002/mp.12090" @default.
- W2569795900 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/28063171" @default.
- W2569795900 hasPublicationYear "2017" @default.
- W2569795900 type Work @default.
- W2569795900 sameAs 2569795900 @default.
- W2569795900 citedByCount "4" @default.
- W2569795900 countsByYear W25697959002018 @default.
- W2569795900 countsByYear W25697959002019 @default.
- W2569795900 countsByYear W25697959002022 @default.
- W2569795900 crossrefType "journal-article" @default.
- W2569795900 hasAuthorship W2569795900A5026442912 @default.
- W2569795900 hasAuthorship W2569795900A5073682650 @default.
- W2569795900 hasAuthorship W2569795900A5089476321 @default.
- W2569795900 hasBestOaLocation W25697959001 @default.
- W2569795900 hasConcept C120665830 @default.
- W2569795900 hasConcept C121332964 @default.
- W2569795900 hasConcept C126838900 @default.
- W2569795900 hasConcept C143409427 @default.
- W2569795900 hasConcept C168834538 @default.
- W2569795900 hasConcept C180048950 @default.
- W2569795900 hasConcept C19527891 @default.
- W2569795900 hasConcept C2989005 @default.
- W2569795900 hasConcept C31601959 @default.
- W2569795900 hasConcept C509974204 @default.
- W2569795900 hasConcept C71924100 @default.
- W2569795900 hasConcept C75088862 @default.
- W2569795900 hasConceptScore W2569795900C120665830 @default.
- W2569795900 hasConceptScore W2569795900C121332964 @default.
- W2569795900 hasConceptScore W2569795900C126838900 @default.
- W2569795900 hasConceptScore W2569795900C143409427 @default.
- W2569795900 hasConceptScore W2569795900C168834538 @default.
- W2569795900 hasConceptScore W2569795900C180048950 @default.
- W2569795900 hasConceptScore W2569795900C19527891 @default.
- W2569795900 hasConceptScore W2569795900C2989005 @default.
- W2569795900 hasConceptScore W2569795900C31601959 @default.
- W2569795900 hasConceptScore W2569795900C509974204 @default.
- W2569795900 hasConceptScore W2569795900C71924100 @default.
- W2569795900 hasConceptScore W2569795900C75088862 @default.
- W2569795900 hasIssue "3" @default.
- W2569795900 hasLocation W25697959001 @default.
- W2569795900 hasLocation W25697959002 @default.
- W2569795900 hasOpenAccess W2569795900 @default.
- W2569795900 hasPrimaryLocation W25697959001 @default.
- W2569795900 hasRelatedWork W1972877072 @default.
- W2569795900 hasRelatedWork W2064873898 @default.
- W2569795900 hasRelatedWork W2065864741 @default.
- W2569795900 hasRelatedWork W2068340264 @default.
- W2569795900 hasRelatedWork W2103123203 @default.
- W2569795900 hasRelatedWork W2115968180 @default.
- W2569795900 hasRelatedWork W2163242481 @default.
- W2569795900 hasRelatedWork W2412325395 @default.
- W2569795900 hasRelatedWork W4205482557 @default.
- W2569795900 hasRelatedWork W4285153207 @default.
- W2569795900 hasVolume "44" @default.
- W2569795900 isParatext "false" @default.
- W2569795900 isRetracted "false" @default.
- W2569795900 magId "2569795900" @default.
- W2569795900 workType "article" @default.