Matches in SemOpenAlex for { <https://semopenalex.org/work/W2747595255> ?p ?o ?g. }
Showing items 1 to 72 of
72
with 100 items per page.
- W2747595255 abstract "The Levelized Cost of Electricity (LCOE) of Concentrated Solar Power, referred to in this document as Solar Thermal Electric (STE) is no match for that of Photovoltaic (about one third in similar conditions). However, the future electrical grids dominated by intermittent renewables (in 2030 and beyond) will value the firm capacity provided by STE that integrate a massive thermal storage. The molten salt solar tower is, beyond any doubt, the best technology to provide this firm capacity at reasonable cost for the 10–15 years to come. We believe that the next generation of STE plants will keep the molten salt tower architecture, but with novel solar loop, storage medium and power block that will allow for higher working temperatures and conversion efficiency, thereby downsizing the solar field that accounts for ∼40% of the plant’s LCOE. Among the three power block technologies that can make good use of the high temperatures allowed by the new storage medium (probably fluidized particles) — supercritical steam Rankine cycle, supercritical CO2 Brayton cycle and combined cycle gas turbine (CCGT) — the latter is a good candidate. In order to achieve today’s impressive efficiencies of state-of-the-art gas-fired CCGTs (up to 62%), the manufacturers relied on continuous improvements — including Turbine Inlet Temperatures (TIT) increases up to ∼1500°C — without modifying the architecture. Our problem is quite different: we consider that our TIT is limited to 1,000°C. Therefore, new architectures must be contemplated in order to reach a ∼50% efficiency that would be a significant improvement compared to the ∼42% obtained with current subcritical steam cycles. The objective of this study is to define the optimal configuration of a CCGT working with an external heat input provided by heat exchangers that collect the heat from a storage medium. The study was conducted as follows. The bottoming cycle’s power output per unit of GT exhaust gas mass flow was defined as a function of the exhaust gas temperature thanks to several simulations performed with Thermoflow’s GT-PRO software and a linear regression. Our efforts were then focused on the gas turbine. Four gas turbine configurations were optimized and compared: with/without reheat, with/without intercooling. Single and double reheat were also compared. For each configuration, three TIT values were considered: 800°C, 900°C and 1,000°C. A supplementary combustion that entails a 6% pressure drop was considered after the external heat and reheat(s). These calculations were performed twice: first using an analytic model, then with the Thermoflex software. Both results were always very consistent, which is no surprise: since the gas turbine is uncooled, the analytical model is straightforward. The single reheat cycle without intercooling is the most efficient one if TIT ≥ 900°C. The double reheat increases the efficiency for TIT = 800°C. The gross efficiencies of the combined cycle power blocks with single reheat GT with additional combustion are as follows: 46.8% if TIT = 800°C (49.7% with a double reheat and no additional combustion), 50.3% if TIT = 900°C and 53.1% if TIT = 1,000°C. The reheat (or second reheat if applicable) poses a considerable challenge because the low working air pressure entails a high relative pressure drop of the heat exchanger that is highly detrimental to the cycle efficiency. According to expert opinion, a train of reheat exchangers with the pressure drop considered in this study (6%) and a ∼50 K final temperature difference can be manufactured at reasonable cost. The Capital Expenditure (Capex) of the CCGT plus its trains of heat exchangers must be assessed in collaboration with manufacturers but should be reasonable, lower anyway than that of a supercritical steam cycle with similar efficiency. In conclusion, a low TIT, externally heated CCGT with single or double reheat (depending on the TIT) is a good option for the next generation of high temperature solar towers. There is no major hurdle for manufacturing such a power block right now, other than convincing a manufacturer to do it." @default.
- W2747595255 created "2017-08-31" @default.
- W2747595255 creator A5044636997 @default.
- W2747595255 creator A5069039433 @default.
- W2747595255 date "2017-06-26" @default.
- W2747595255 modified "2023-09-28" @default.
- W2747595255 title "Optimisation of a Low-TIT Combined Cycle Gas Turbine With Application to New Generation Solar Thermal Power Plants" @default.
- W2747595255 doi "https://doi.org/10.1115/gt2017-65227" @default.
- W2747595255 hasPublicationYear "2017" @default.
- W2747595255 type Work @default.
- W2747595255 sameAs 2747595255 @default.
- W2747595255 citedByCount "4" @default.
- W2747595255 countsByYear W27475952552019 @default.
- W2747595255 countsByYear W27475952552020 @default.
- W2747595255 countsByYear W27475952552021 @default.
- W2747595255 countsByYear W27475952552022 @default.
- W2747595255 crossrefType "proceedings-article" @default.
- W2747595255 hasAuthorship W2747595255A5044636997 @default.
- W2747595255 hasAuthorship W2747595255A5069039433 @default.
- W2747595255 hasConcept C110910425 @default.
- W2747595255 hasConcept C121332964 @default.
- W2747595255 hasConcept C127413603 @default.
- W2747595255 hasConcept C153294291 @default.
- W2747595255 hasConcept C163258240 @default.
- W2747595255 hasConcept C171146098 @default.
- W2747595255 hasConcept C204530211 @default.
- W2747595255 hasConcept C2778449969 @default.
- W2747595255 hasConcept C2987684023 @default.
- W2747595255 hasConcept C39432304 @default.
- W2747595255 hasConcept C423512 @default.
- W2747595255 hasConcept C78519656 @default.
- W2747595255 hasConcept C97355855 @default.
- W2747595255 hasConceptScore W2747595255C110910425 @default.
- W2747595255 hasConceptScore W2747595255C121332964 @default.
- W2747595255 hasConceptScore W2747595255C127413603 @default.
- W2747595255 hasConceptScore W2747595255C153294291 @default.
- W2747595255 hasConceptScore W2747595255C163258240 @default.
- W2747595255 hasConceptScore W2747595255C171146098 @default.
- W2747595255 hasConceptScore W2747595255C204530211 @default.
- W2747595255 hasConceptScore W2747595255C2778449969 @default.
- W2747595255 hasConceptScore W2747595255C2987684023 @default.
- W2747595255 hasConceptScore W2747595255C39432304 @default.
- W2747595255 hasConceptScore W2747595255C423512 @default.
- W2747595255 hasConceptScore W2747595255C78519656 @default.
- W2747595255 hasConceptScore W2747595255C97355855 @default.
- W2747595255 hasLocation W27475952551 @default.
- W2747595255 hasOpenAccess W2747595255 @default.
- W2747595255 hasPrimaryLocation W27475952551 @default.
- W2747595255 hasRelatedWork W1557668783 @default.
- W2747595255 hasRelatedWork W2057300316 @default.
- W2747595255 hasRelatedWork W2522082777 @default.
- W2747595255 hasRelatedWork W2548837300 @default.
- W2747595255 hasRelatedWork W2611295055 @default.
- W2747595255 hasRelatedWork W2751407460 @default.
- W2747595255 hasRelatedWork W2769975588 @default.
- W2747595255 hasRelatedWork W2802859252 @default.
- W2747595255 hasRelatedWork W2890930174 @default.
- W2747595255 hasRelatedWork W2920030486 @default.
- W2747595255 hasRelatedWork W2984433160 @default.
- W2747595255 hasRelatedWork W2993365632 @default.
- W2747595255 hasRelatedWork W3011026098 @default.
- W2747595255 hasRelatedWork W3122302531 @default.
- W2747595255 hasRelatedWork W3163262644 @default.
- W2747595255 hasRelatedWork W2832027059 @default.
- W2747595255 hasRelatedWork W2836504087 @default.
- W2747595255 hasRelatedWork W2976159544 @default.
- W2747595255 hasRelatedWork W3020260744 @default.
- W2747595255 hasRelatedWork W3027629450 @default.
- W2747595255 isParatext "false" @default.
- W2747595255 isRetracted "false" @default.
- W2747595255 magId "2747595255" @default.
- W2747595255 workType "article" @default.