Matches in SemOpenAlex for { <https://semopenalex.org/work/W2893308575> ?p ?o ?g. }
Showing items 1 to 76 of
76
with 100 items per page.
- W2893308575 endingPage "638" @default.
- W2893308575 startingPage "630" @default.
- W2893308575 abstract "El Doppler transcraneal (DTC) es una técnica de monitorización no invasiva de la velocidad del flujo sanguíneo cerebral en las principales arterias intracraneales, especialmente las arterias del polígono de Willis. Nuestro propósito es analizar mediante Eco Doppler pulsado, si durante la anestesia inhalatoria en pediatría, las alteraciones del flujo sanguíneo cerebral (FSC), se corresponden con modificaciones en los valores medidos de índice biespectral (BIS) y entropía espectral de electroencefalograma (EEG) (Estado y Respuesta). Estudio observacional prospectivo, ciego, en 36 pacientes de 5 a 11 años, ASA I-II, bajo anestesia general inhalatoria, para cirugía general menor. Se indujo la anestesia con sevoflurano. Se mantuvo anestesia con sevoflurano al 2,5% en O2/Aire (FiO250%). Se utilizó remifentanilo en perfusión continua para analgesia. Se monitorizó variables hemodinámicas y respiratorias, de gases, temperatura, patrón de hipnosis (BIS y Entropía –ES y ER–), y patrón de flujo sanguíneo cerebral estimado (sonografía Doppler pulsada) en la arteria cerebral media. Se obtuvieron los parámetros de índice de resistencia, índice de pulsatilidad, velocidad media y flujo sanguíneo estimado. Se determinaron correlaciones (r de Pearson) para los valores de BIS, ES, ER, índice de pulsatilidad, índice de resistencia, velocidad media, FSC estimado, FETCO2 y Tª obtenidos. Se determinó la existencia de modelos de regresión. La inducción produjo un sonograma con patrón de alta velocidad (elevación de velocidad media, índice de pulsatilidad normal o disminuido) hasta obtener el valor más bajo de BIS y ES (31 y 29). Durante el mantenimiento se presentó un patrón de sonografía más enlentecido (normalización de índice de pulsatilidad, índice de resistencia y velocidad media), existiendo correlación estadística y concordancia entre las modificaciones de flujo y los valores absolutos de entropía y BIS (–Pearson– r [H11350] ± 0,91. Concordancia Doppler-Bis de 93,4%); coincidentes con valores de BIS y ES de 35–45. En el despertar, las velocidades de flujo se acercaron a cifras basales cuando los valores de BIS y ES ascendieron a 98–90. Se detectaron modificaciones puntuales de FSC coincidentes con elevación o descenso casi concomitante de BIS (r > 0,95), que presentó un ligero retraso no superior al minuto, y que no fueron detectadas de igual modo por entropía. Proporcionamos los patrones sonográficos en la inducción para sevoflurano. Los sistemas de monitorización de hipnosis podrían ser considerados como sistemas indirectos de medición de flujo cerebral (siendo BIS el de mayor sensibilidad). El DTC permitiría objetivar modificaciones de flujo durante la anestesia relacionados con la profundidad de la hipnosis. Transcranial Doppler ultrasound is a noninvasive technique for monitoring the velocity of blood flow in the main intracranial arteries, particularly those in the circle of Willis. Our aim was to assess whether changes in cerebral arterial blood flow in pediatric patients under sevoflurane anesthesia demonstrated by pulsed Doppler ultrasound correlate with changes in the bispectral (BIS) index and electroencephalographic state and response entropy (ES and ER, respectively). Prospective, blinded observational study of 36 pediatric patients (age range, 5 to 11 years; ASA physical status classification, 1–2) under sevoflurane anesthesia for minor surgical procedures. Anesthesia was induced with sevoflurane and maintained with 2.5% sevoflurane in an inspired oxygen fraction of 50% in air. A continuous perfusion of remifentanil was provided for analgesia. In all patients we monitored hemodynamic and respiratory patterns, gases, temperature, and hypnosis (BIS, ES and ER) as well as cerebral blood flow estimated by pulsed Doppler ultrasound in the middle cerebral artery. The resistance index, pulsatility index, mean velocity, and estimated baseline cerebral blood flow were calculated from the Doppler sonogram. Correlations (Pearson’s r) were calculated between BIS, ES, ER, the pulsatility index, resistance index, mean flow velocity, estimated cerebral blood flow, fraction of end-tidal carbon dioxide, and temperature. A regression model was constructed. Induction caused a pattern of high velocity (elevated mean velocity and normal or reduced pulsatility index) until the lowest BIS and ES values of 31 and 29, respectively, were reached. During maintenance, the Doppler sonogram pattern was slower (normalization of the pulsatility index, the resistance index, and mean velocity). Changes in flow and absolute entropy and BIS values were statistically correlated (Pearson’s r values ≥ 0.91); there was 95.6% agreement between Doppler values and BIS and agreement between BIS and ES values of 35 to 45. On awakening, flow velocities approached baseline values when BIS and ES rose to between 90 and 98. The estimated cerebral blood flow underwent fluctuations coinciding with an approximately concomitant increase or decrease in BIS (r > 0.95); the BIS response occurred with a slight delay of no more than a minute. The entropy measurements did not reflect the fluctuations. We show Doppler ultrasound patterns during anesthetic induction with sevoflurane. Systems for monitoring hypnosis could be considered indirect measurements of cerebral blood flow; BIS measurements are more sensitive to change. Transcranial Doppler ultrasound facilitates the observation of changes in blood flow that occur at different levels of hypnosis during anesthesia." @default.
- W2893308575 created "2018-10-05" @default.
- W2893308575 creator A5011248411 @default.
- W2893308575 creator A5046189985 @default.
- W2893308575 creator A5052021074 @default.
- W2893308575 creator A5073290756 @default.
- W2893308575 creator A5077738954 @default.
- W2893308575 creator A5087069711 @default.
- W2893308575 date "2010-01-01" @default.
- W2893308575 modified "2023-10-02" @default.
- W2893308575 title "Doppler transcraneal, BIS y entropía como medición indirecta del flujo cerebral durante la anestesia inhalatoria en pacientes pediátricos" @default.
- W2893308575 cites W1973854954 @default.
- W2893308575 cites W1985326472 @default.
- W2893308575 cites W1991079836 @default.
- W2893308575 cites W1996044042 @default.
- W2893308575 cites W2007305882 @default.
- W2893308575 cites W2014205116 @default.
- W2893308575 cites W2017065764 @default.
- W2893308575 cites W2020630580 @default.
- W2893308575 cites W2032656032 @default.
- W2893308575 cites W2036296234 @default.
- W2893308575 cites W2059312138 @default.
- W2893308575 cites W2095552123 @default.
- W2893308575 cites W2100188504 @default.
- W2893308575 cites W2111607494 @default.
- W2893308575 cites W2123300471 @default.
- W2893308575 cites W2126204041 @default.
- W2893308575 cites W2129892559 @default.
- W2893308575 cites W2132258502 @default.
- W2893308575 cites W2133745591 @default.
- W2893308575 cites W2136854527 @default.
- W2893308575 cites W2168352792 @default.
- W2893308575 cites W4236366897 @default.
- W2893308575 doi "https://doi.org/10.1016/s0034-9356(10)70299-1" @default.
- W2893308575 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/22283015" @default.
- W2893308575 hasPublicationYear "2010" @default.
- W2893308575 type Work @default.
- W2893308575 sameAs 2893308575 @default.
- W2893308575 citedByCount "2" @default.
- W2893308575 countsByYear W28933085752016 @default.
- W2893308575 countsByYear W28933085752021 @default.
- W2893308575 crossrefType "journal-article" @default.
- W2893308575 hasAuthorship W2893308575A5011248411 @default.
- W2893308575 hasAuthorship W2893308575A5046189985 @default.
- W2893308575 hasAuthorship W2893308575A5052021074 @default.
- W2893308575 hasAuthorship W2893308575A5073290756 @default.
- W2893308575 hasAuthorship W2893308575A5077738954 @default.
- W2893308575 hasAuthorship W2893308575A5087069711 @default.
- W2893308575 hasConcept C138885662 @default.
- W2893308575 hasConcept C15708023 @default.
- W2893308575 hasConcept C71924100 @default.
- W2893308575 hasConceptScore W2893308575C138885662 @default.
- W2893308575 hasConceptScore W2893308575C15708023 @default.
- W2893308575 hasConceptScore W2893308575C71924100 @default.
- W2893308575 hasIssue "10" @default.
- W2893308575 hasLocation W28933085751 @default.
- W2893308575 hasLocation W28933085752 @default.
- W2893308575 hasOpenAccess W2893308575 @default.
- W2893308575 hasPrimaryLocation W28933085751 @default.
- W2893308575 hasRelatedWork W1506200166 @default.
- W2893308575 hasRelatedWork W1995515455 @default.
- W2893308575 hasRelatedWork W2039318446 @default.
- W2893308575 hasRelatedWork W2048182022 @default.
- W2893308575 hasRelatedWork W2080531066 @default.
- W2893308575 hasRelatedWork W2604872355 @default.
- W2893308575 hasRelatedWork W2748952813 @default.
- W2893308575 hasRelatedWork W2899084033 @default.
- W2893308575 hasRelatedWork W3032375762 @default.
- W2893308575 hasRelatedWork W3108674512 @default.
- W2893308575 hasVolume "57" @default.
- W2893308575 isParatext "false" @default.
- W2893308575 isRetracted "false" @default.
- W2893308575 magId "2893308575" @default.
- W2893308575 workType "article" @default.