Matches in SemOpenAlex for { <https://semopenalex.org/work/W2913443478> ?p ?o ?g. }
Showing items 1 to 29 of
29
with 100 items per page.
- W2913443478 endingPage "118" @default.
- W2913443478 startingPage "117" @default.
- W2913443478 abstract "espanolEn la actualidad existe una necesidad creciente de realizar evaluaciones de estructuras existentes de hormigon armado deterioradas. Esto se debe tanto al cambio en el uso previsto de la obra como a la ampliacion de su periodo de servicio. Ante esta situacion es necesario disponer de modelos de resistencia que incorporen el deterioro en la verificacion de la seguridad estructural y, ademas, disponer de criterios racionales tanto para el refuerzo como para la rehabilitacion de estructuras existentes deterioradas por corrosion. Diversos estudios experimentales se han realizado en los ultimos anos relacionados con modelos de resistencia que incorporan, fundamentalmente, el deterioro por corrosion. Los resultados de dichos estudios se deben tomar con cautela debido a que: Los procesos de deterioro se realizaron principalmente mediante tecnicas de corrosion acelerada por lo que es posible que la corrosion natural pueda tener un comportamiento diferente. Los elementos estudiados eran de pequenas dimensiones y fabricados en condiciones de laboratorio. Por lo tanto es necesario verificar si estos modelos son adecuados para elementos de grandes dimensiones. Por estas razones, la demolicion de un edificio industrial de hormigon armado de 1940 en la costa de Galicia era una oportunidad unica para la evaluacion estructural de elementos reales de grandes dimensiones y con deterioro natural. Para este estudio se seleccionaron ocho vigas que se cortaron in situ mediante disco e hilo de diamante para evitar danos adicionales. Posteriormente se realizaron ensayos de flexion en 4 y 3 puntos para determinar su capacidad resistente. La evaluacion de la capacidad portante de dichas vigas se basa en el teorema del limite inferior de la plasticidad. Primero se establecen modelos de campo de tensiones para determinar la resistencia en las zonas criticas a partir de modelos de resistencia simplificados que se encuentran en los codigos estructurales (EN-1992-1-1 y ModelCode-2010) incorporando la informacion a priori de la geometria (medida antes de llevar a cabo los ensayos) y de los materiales (obtenidas de elementos del mismo edificio). En la segunda etapa, la capacidad resistente se evalua de nuevo incorporando la informacion con respecto a la geometria de las secciones criticas y las propiedades de los materiales de cada una de las vigas. Finalmente se compara la capacidad resistente de una de las vigas ensayadas en funcion de la informacion disponible en la evaluacion. El procedimiento descrito anteriormente se puede utilizar en la evaluacion de la seguridad de vigas existentes deterioradas por corrosion. EnglishActually there is growing need for the assessment of existing damaged reinforced concrete structures. This is due to both the change of use and the extension of their service life. In view of this situation there is a need for resistance models that take deterioration processes into account to assess structural safety and also to have consistent criteria for the upgrading and refurbishment of damaged reinforced concrete structures. A number of experimental studies have been conducted in recent years on resistance models that take deterioration into account, primarily due to corrosion. The findings should be taken with care, however, for the following reasons:#Deterioration processes were produced mostly with acceleration techniques. Natural deterioration might therefore have a different performance. The members studied were of small dimensions and casted in laboratory conditions. For this reason it is necessary to verify whether these resistance models are suitable on members with larger dimensions. In light of this shortfall, the change of use of a 1940`s industrial building of reinforced concrete in the Galician coast was an unique opportunity to study the performance of real members with larger dimensions and naturally damaged. For the present study, eight beams were selected and cut in place with diamond cutting techniques, wall and wire saw, to avoid further damage to the beams. Subsequently, 4-point and 3-point bending tests were conducted to determine their load bearing capacity. The assessment of the load bearing capacity of these beams is based on the lower bound theorem of the theory of plasticity. In the first step, stress field models are established determining the resistance in critical regions from suitably adapted simplified resistance models described in structural code (EN-1992-1-1 and ModelCode-2010) incorporating the required prior information regarding to geometry (measured before conducting the tests) and material properties (obtained from members of the same building). In the second step, the load bearing capacity is assessed with the same models but incorporating new information from each one of the tested beams about the geometry of the critical sections and the material properties. Finally, a comparison between the load bearing capacity of one of the tested beams regarding to the available information used in the assessment is carried out and discussed. The procedure described above may be used in the safety assessment of existing deteriorated concrete structures." @default.
- W2913443478 created "2019-02-21" @default.
- W2913443478 creator A5046060955 @default.
- W2913443478 creator A5064742511 @default.
- W2913443478 creator A5087419163 @default.
- W2913443478 date "2014-01-01" @default.
- W2913443478 modified "2023-09-28" @default.
- W2913443478 title "Evaluación de la capacidad resistente de vigas deterioradas por corrosión sometidas a un ambiente marino durante 70 años" @default.
- W2913443478 hasPublicationYear "2014" @default.
- W2913443478 type Work @default.
- W2913443478 sameAs 2913443478 @default.
- W2913443478 citedByCount "0" @default.
- W2913443478 crossrefType "journal-article" @default.
- W2913443478 hasAuthorship W2913443478A5046060955 @default.
- W2913443478 hasAuthorship W2913443478A5064742511 @default.
- W2913443478 hasAuthorship W2913443478A5087419163 @default.
- W2913443478 hasConcept C138885662 @default.
- W2913443478 hasConcept C15708023 @default.
- W2913443478 hasConceptScore W2913443478C138885662 @default.
- W2913443478 hasConceptScore W2913443478C15708023 @default.
- W2913443478 hasLocation W29134434781 @default.
- W2913443478 hasOpenAccess W2913443478 @default.
- W2913443478 hasPrimaryLocation W29134434781 @default.
- W2913443478 isParatext "false" @default.
- W2913443478 isRetracted "false" @default.
- W2913443478 magId "2913443478" @default.
- W2913443478 workType "article" @default.