Matches in SemOpenAlex for { <https://semopenalex.org/work/W2947503447> ?p ?o ?g. }
Showing items 1 to 80 of
80
with 100 items per page.
- W2947503447 abstract "Background An adequate airway management plan is essential for patient safety. Recently, new tools have been developed as alternatives to direct laryngoscopy and intubation. Among these, video-laryngoscopy has enjoyed a rapid increase in popularity and is now considered by many as the first-line technique in airway management. This paradigm shift may have an impact on patient safety. Principal findings Studies show that video-laryngoscopes are associated with better glottic visualization, a higher success rate for difficult airways, and a faster learning curve, resulting in a higher success rate for intubations by novice physicians. Thus, unanticipated difficult intubations may be less frequent if video-laryngoscopy is used as the first-line approach. In addition, on-screen viewing by the operator creates a new dynamic interaction during airway management. The entire operating room team can assess progress in real time, which enhances communication and improves teaching. However, if video-laryngoscopes become standard tools for tracheal intubation, these more costly devices will need to be widely available in all locations where airway management is conducted. Furthermore, algorithms for difficult intubation will require modification, and the question of selecting alternate devices will arise. If the incidence of difficult intubation decreases, the lack of motivation to teach and learn the use of alternative devices might adversely impact patient safety. Conclusion The greater effectiveness of video-laryngoscopes associated with multi-person visualization could enhance overall patient safety during airway management. However, the routine use of video-laryngoscopy also introduces some issues that need to be addressed to avoid potentially dangerous pitfalls. Resume Contexte Une prise en charge adaptee des voies aeriennes est essentielle a la securite des patients. De nouvelles alternatives a la laryngoscopie directe et a l’intubation ont ete recemment developpees. Parmi elles, la video-laryngoscopie est devenue rapidement populaire et beaucoup la considerent maintenant comme la technique de premiere intention pour la prise en charge des voies aeriennes. Ce changement de paradigme pourrait avoir un impact sur la securite des patients. Constatations principales Les etudes montrent que les video-laryngoscopes sont associes a une meilleure visualisation de la glotte, un taux de reussite superieur en cas de voies aeriennes difficiles et une courbe d’apprentissage plus rapide, aboutissant a des taux de reussite plus eleves pour les intubations realisees par des medecins novices. En consequence, les intubations difficiles inattendues pourraient etre moins frequentes si la video-laryngoscopie etait utilisee comme approche de premiere intention. De plus, le suivi sur ecran par l’operateur cree une nouvelle dynamique interactive au cours de la prise en charge des voies aeriennes. Toute l’equipe de la salle d’operation peut evaluer l’evolution en temps reel, ce qui encourage la communication et ameliore l’enseignement. Cependant, si les video-laryngoscopes deviennent des outils standard pour l’intubation tracheale, ces dispositifs plus couteux doivent devenir largement disponibles dans tous les endroits ou J.-B. Paolini, MD (&) F. Donati, MD, PhD P. Drolet, MD Departement d’anesthesiologie, Universite de Montreal, Montreal, QC, Canada e-mail: jbpaolini@yahoo.fr 123 Can J Anesth/J Can Anesth (2013) 60:184–191 DOI 10.1007/s12630-012-9859-5" @default.
- W2947503447 created "2019-06-07" @default.
- W2947503447 creator A5000488608 @default.
- W2947503447 creator A5022147948 @default.
- W2947503447 date "2013-01-01" @default.
- W2947503447 modified "2023-10-12" @default.
- W2947503447 title "Review article: Video-laryngoscopy: another tool for difficult intubation or a new paradigm in airway management? Article de synthèse: La vidéo-laryngoscopie: un autre outil pour les intubations difficiles ou un nouveau paradigme pour la prise en charge des voies aériennes?" @default.
- W2947503447 cites W1522608274 @default.
- W2947503447 cites W1562085292 @default.
- W2947503447 cites W1965115380 @default.
- W2947503447 cites W1970453815 @default.
- W2947503447 cites W1971231312 @default.
- W2947503447 cites W1978202479 @default.
- W2947503447 cites W1985972065 @default.
- W2947503447 cites W1988797689 @default.
- W2947503447 cites W1995786745 @default.
- W2947503447 cites W1996859235 @default.
- W2947503447 cites W2002444753 @default.
- W2947503447 cites W2041463792 @default.
- W2947503447 cites W2065649545 @default.
- W2947503447 cites W2072289491 @default.
- W2947503447 cites W2093544523 @default.
- W2947503447 cites W2094377228 @default.
- W2947503447 cites W2102325787 @default.
- W2947503447 cites W2104382728 @default.
- W2947503447 cites W2105119499 @default.
- W2947503447 cites W2106709024 @default.
- W2947503447 cites W2108214974 @default.
- W2947503447 cites W2108923454 @default.
- W2947503447 cites W2112745821 @default.
- W2947503447 cites W2118554508 @default.
- W2947503447 cites W2124024380 @default.
- W2947503447 cites W2131173864 @default.
- W2947503447 cites W2133167770 @default.
- W2947503447 cites W2136896143 @default.
- W2947503447 cites W2149804175 @default.
- W2947503447 cites W2150255105 @default.
- W2947503447 cites W2153769995 @default.
- W2947503447 cites W2163335760 @default.
- W2947503447 cites W2271281458 @default.
- W2947503447 cites W2286658784 @default.
- W2947503447 cites W3083145462 @default.
- W2947503447 hasPublicationYear "2013" @default.
- W2947503447 type Work @default.
- W2947503447 sameAs 2947503447 @default.
- W2947503447 citedByCount "0" @default.
- W2947503447 crossrefType "journal-article" @default.
- W2947503447 hasAuthorship W2947503447A5000488608 @default.
- W2947503447 hasAuthorship W2947503447A5022147948 @default.
- W2947503447 hasConcept C105922876 @default.
- W2947503447 hasConcept C160735492 @default.
- W2947503447 hasConcept C162324750 @default.
- W2947503447 hasConcept C177713679 @default.
- W2947503447 hasConcept C2776888792 @default.
- W2947503447 hasConcept C2778716859 @default.
- W2947503447 hasConcept C2779328685 @default.
- W2947503447 hasConcept C2780978852 @default.
- W2947503447 hasConcept C2910000593 @default.
- W2947503447 hasConcept C42219234 @default.
- W2947503447 hasConcept C50522688 @default.
- W2947503447 hasConcept C71924100 @default.
- W2947503447 hasConceptScore W2947503447C105922876 @default.
- W2947503447 hasConceptScore W2947503447C160735492 @default.
- W2947503447 hasConceptScore W2947503447C162324750 @default.
- W2947503447 hasConceptScore W2947503447C177713679 @default.
- W2947503447 hasConceptScore W2947503447C2776888792 @default.
- W2947503447 hasConceptScore W2947503447C2778716859 @default.
- W2947503447 hasConceptScore W2947503447C2779328685 @default.
- W2947503447 hasConceptScore W2947503447C2780978852 @default.
- W2947503447 hasConceptScore W2947503447C2910000593 @default.
- W2947503447 hasConceptScore W2947503447C42219234 @default.
- W2947503447 hasConceptScore W2947503447C50522688 @default.
- W2947503447 hasConceptScore W2947503447C71924100 @default.
- W2947503447 hasLocation W29475034471 @default.
- W2947503447 hasOpenAccess W2947503447 @default.
- W2947503447 hasPrimaryLocation W29475034471 @default.
- W2947503447 isParatext "false" @default.
- W2947503447 isRetracted "false" @default.
- W2947503447 magId "2947503447" @default.
- W2947503447 workType "article" @default.