- W2958696211 abstract "We have developed a second-generation virtual-pinhole (VP) positron emission tomography (PET) device that can position a flat-panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region-of-interest using a whole-body PET/computed tomography (CT) scanner.We constructed a flat-panel VP-PET device using 32 high-resolution detectors, each containing a 4 × 4 MPPC array and 16 × 16 LYSO crystals of 1.0 × 1.0 × 3.0 mm3 each. The flat-panel detectors can be positioned around a patient's body anywhere in the imaging field-of-view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP-PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP-PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 × 228 × 162 mm3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP-PET device. Images were reconstructed using a list mode Maximum-Likelihood Estimation-Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP-PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP-PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP-PET device over the native PET/CT scanner.The repeatability in positioning the flat-panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP-PET insert device with the flat-panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual-panel VP-PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP-PET device that has a single flat-panel detector. The improvement is greater if the VP-PET device employs a dual-panel design.We have developed a prototype flat-panel VP-PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions-of-interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP-PET device. This technology may become a cost-effective solution for organ-specific imaging tasks." @default.
- W2958696211 created "2019-07-23" @default.
- W2958696211 creator A5010109677 @default.
- W2958696211 creator A5017100408 @default.
- W2958696211 creator A5020936192 @default.
- W2958696211 creator A5030863883 @default.
- W2958696211 creator A5044333105 @default.
- W2958696211 creator A5051303178 @default.
- W2958696211 creator A5077671366 @default.
- W2958696211 creator A5081009588 @default.
- W2958696211 date "2019-08-07" @default.
- W2958696211 modified "2023-10-13" @default.
- W2958696211 title "A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner" @default.
- W2958696211 cites W1494052777 @default.
- W2958696211 cites W1759875101 @default.
- W2958696211 cites W1923362618 @default.
- W2958696211 cites W1968331395 @default.
- W2958696211 cites W1975649801 @default.
- W2958696211 cites W1979298638 @default.
- W2958696211 cites W1980694088 @default.
- W2958696211 cites W1987314126 @default.
- W2958696211 cites W1994242225 @default.
- W2958696211 cites W2005466494 @default.
- W2958696211 cites W2022044137 @default.
- W2958696211 cites W2035655339 @default.
- W2958696211 cites W2038113011 @default.
- W2958696211 cites W2041379652 @default.
- W2958696211 cites W2050335258 @default.
- W2958696211 cites W2064990216 @default.
- W2958696211 cites W2069841093 @default.
- W2958696211 cites W2069859704 @default.
- W2958696211 cites W2075734152 @default.
- W2958696211 cites W2081650101 @default.
- W2958696211 cites W2083264163 @default.
- W2958696211 cites W2089502051 @default.
- W2958696211 cites W2093162406 @default.
- W2958696211 cites W2099676413 @default.
- W2958696211 cites W2107385382 @default.
- W2958696211 cites W2117305340 @default.
- W2958696211 cites W2118318615 @default.
- W2958696211 cites W2122964209 @default.
- W2958696211 cites W2124087039 @default.
- W2958696211 cites W2125345610 @default.
- W2958696211 cites W2139043139 @default.
- W2958696211 cites W2144904402 @default.
- W2958696211 cites W2151843995 @default.
- W2958696211 cites W2156617598 @default.
- W2958696211 cites W2165092775 @default.
- W2958696211 cites W2165318151 @default.
- W2958696211 cites W2166462970 @default.
- W2958696211 cites W2166934514 @default.
- W2958696211 cites W2170591739 @default.
- W2958696211 cites W2171902542 @default.
- W2958696211 cites W2172217142 @default.
- W2958696211 cites W2218124377 @default.
- W2958696211 cites W2265071295 @default.
- W2958696211 cites W2326128229 @default.
- W2958696211 cites W236140065 @default.
- W2958696211 cites W2415291192 @default.
- W2958696211 cites W2532039271 @default.
- W2958696211 cites W2758460516 @default.
- W2958696211 cites W2913409883 @default.
- W2958696211 cites W3202857298 @default.
- W2958696211 cites W40005850 @default.
- W2958696211 doi "https://doi.org/10.1002/mp.13724" @default.
- W2958696211 hasPubMedCentralId "https://www.ncbi.nlm.nih.gov/pmc/articles/6739194" @default.
- W2958696211 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/31315157" @default.
- W2958696211 hasPublicationYear "2019" @default.
- W2958696211 type Work @default.
- W2958696211 sameAs 2958696211 @default.
- W2958696211 citedByCount "13" @default.
- W2958696211 countsByYear W29586962112020 @default.
- W2958696211 countsByYear W29586962112021 @default.
- W2958696211 countsByYear W29586962112022 @default.
- W2958696211 countsByYear W29586962112023 @default.
- W2958696211 crossrefType "journal-article" @default.
- W2958696211 hasAuthorship W2958696211A5010109677 @default.
- W2958696211 hasAuthorship W2958696211A5017100408 @default.
- W2958696211 hasAuthorship W2958696211A5020936192 @default.
- W2958696211 hasAuthorship W2958696211A5030863883 @default.
- W2958696211 hasAuthorship W2958696211A5044333105 @default.
- W2958696211 hasAuthorship W2958696211A5051303178 @default.
- W2958696211 hasAuthorship W2958696211A5077671366 @default.
- W2958696211 hasAuthorship W2958696211A5081009588 @default.
- W2958696211 hasBestOaLocation W29586962113 @default.
- W2958696211 hasConcept C104293457 @default.
- W2958696211 hasConcept C120665830 @default.
- W2958696211 hasConcept C121332964 @default.
- W2958696211 hasConcept C127077266 @default.
- W2958696211 hasConcept C150627866 @default.
- W2958696211 hasConcept C161694136 @default.
- W2958696211 hasConcept C2775842073 @default.
- W2958696211 hasConcept C2779751349 @default.
- W2958696211 hasConcept C2780330291 @default.
- W2958696211 hasConcept C2989005 @default.
- W2958696211 hasConcept C34445779 @default.
- W2958696211 hasConcept C41008148 @default.
- W2958696211 hasConcept C520434653 @default.