- W2959891061 abstract "EN 14791 is a European Standard Reference method for the measurement of SO2 in emissions. This standard is based on a wet-chemical method in which SO2 present in flue gases is absorbed into an absorption solution containing hydrogen peroxide, and analyzed as sulfates after sampling. This study presents the results obtained when three portable automated measuring systems (P-AMS), based on Fourier-transform infrared (FTIR) spectroscopy, non-dispersive infrared (NDIR) and ultraviolet-fluorescence (UV) techniques, were compared to the Standard Reference Method for SO2 (EN 14791) in order to verify whether they could be used as alternative methods (AM) to EN 14791. In the case of FTIR, the measurements were performed from hot and wet gas, without any conditioning. UV-fluorescence analyzers were equipped with dilution probes and one NDIR applied a permeation dryer, whereas the other had a chiller. Tests were carried out at concentration ranges from 0 to 200 mg/m3(n) and from 0 to 800 mg/m3(n) for testing of equivalency according to CEN/TS 14793 using a test bench. Equivalency test criteria were met for all tested P-AMS except for NDIR at the lower range. The SO2 results measured with NDIR and the chiller were lower compared to the set-up with NDIR and permeation. This was most probably due to the chiller causing absorption of SO2 in the condensate. Tests were also carried out at field conditions, measuring the SO2 emissions from a boiler combusting mainly bark. The same phenomena were observed in these tests as during the test bench study, i.e. the measurement set-up with NDIR and the chiller gave the lowest results. These data demonstrated that the tested alternative methods (FTIR, UV-fluorescence, and NDIR) could be used instead of the standard reference method EN 14791, thus providing real-time calibration of automated measuring systems. It must however be emphasized that when measuring water-soluble gases, such as SO2, the choice of suitable conditioning technique is critical in order to minimize losses of the studied component in the condensate.Implications: Portable automated measuring systems (P-AMS) provide real-time information about emissions and their concentrations, thus offering significant advantages compared to wet-chemical methods. This study presents results which can be used as a validation protocol to show that the tested P-AMS techniques (FTIR, NDIR, UV-fluorescence) could be used instead of EN 14791 (CEN 2017a) as alternative methods (AM), when paying attention to the selection of an appropriate conditioning technique." @default.
- W2959891061 created "2019-07-23" @default.
- W2959891061 creator A5006153859 @default.
- W2959891061 creator A5043731521 @default.
- W2959891061 creator A5066125020 @default.
- W2959891061 date "2019-08-05" @default.
- W2959891061 modified "2023-09-27" @default.
- W2959891061 title "SO<sub>2</sub> emission measurement with the European standard reference method, EN 14791, and alternative methods – observations from laboratory and field studies" @default.
- W2959891061 cites W1956073560 @default.
- W2959891061 doi "https://doi.org/10.1080/10962247.2019.1640809" @default.
- W2959891061 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/31298978" @default.
- W2959891061 hasPublicationYear "2019" @default.
- W2959891061 type Work @default.
- W2959891061 sameAs 2959891061 @default.
- W2959891061 citedByCount "2" @default.
- W2959891061 countsByYear W29598910612022 @default.
- W2959891061 countsByYear W29598910612023 @default.
- W2959891061 crossrefType "journal-article" @default.
- W2959891061 hasAuthorship W2959891061A5006153859 @default.
- W2959891061 hasAuthorship W2959891061A5043731521 @default.
- W2959891061 hasAuthorship W2959891061A5066125020 @default.
- W2959891061 hasBestOaLocation W29598910611 @default.
- W2959891061 hasConcept C105923489 @default.
- W2959891061 hasConcept C107872376 @default.
- W2959891061 hasConcept C113196181 @default.
- W2959891061 hasConcept C121332964 @default.
- W2959891061 hasConcept C160892712 @default.
- W2959891061 hasConcept C167206829 @default.
- W2959891061 hasConcept C178790620 @default.
- W2959891061 hasConcept C185592680 @default.
- W2959891061 hasConcept C62520636 @default.
- W2959891061 hasConceptScore W2959891061C105923489 @default.
- W2959891061 hasConceptScore W2959891061C107872376 @default.
- W2959891061 hasConceptScore W2959891061C113196181 @default.
- W2959891061 hasConceptScore W2959891061C121332964 @default.
- W2959891061 hasConceptScore W2959891061C160892712 @default.
- W2959891061 hasConceptScore W2959891061C167206829 @default.
- W2959891061 hasConceptScore W2959891061C178790620 @default.
- W2959891061 hasConceptScore W2959891061C185592680 @default.
- W2959891061 hasConceptScore W2959891061C62520636 @default.
- W2959891061 hasFunder F4320313458 @default.
- W2959891061 hasIssue "9" @default.
- W2959891061 hasLocation W29598910611 @default.
- W2959891061 hasLocation W29598910612 @default.
- W2959891061 hasOpenAccess W2959891061 @default.
- W2959891061 hasPrimaryLocation W29598910611 @default.
- W2959891061 hasRelatedWork W2000849552 @default.
- W2959891061 hasRelatedWork W2023607525 @default.
- W2959891061 hasRelatedWork W2048517929 @default.
- W2959891061 hasRelatedWork W2054071901 @default.
- W2959891061 hasRelatedWork W2313735840 @default.
- W2959891061 hasRelatedWork W2364650970 @default.
- W2959891061 hasRelatedWork W2791447111 @default.
- W2959891061 hasRelatedWork W3154960385 @default.
- W2959891061 hasRelatedWork W4366310567 @default.
- W2959891061 hasRelatedWork W4377030150 @default.
- W2959891061 hasVolume "69" @default.
- W2959891061 isParatext "false" @default.
- W2959891061 isRetracted "false" @default.
- W2959891061 magId "2959891061" @default.
- W2959891061 workType "article" @default.