Matches in SemOpenAlex for { <https://semopenalex.org/work/W2978078464> ?p ?o ?g. }
Showing items 1 to 92 of
92
with 100 items per page.
- W2978078464 endingPage "258" @default.
- W2978078464 startingPage "255" @default.
- W2978078464 abstract "•Early diagnosis of ALAFs and immediate management are mandatory to reduce mortality.•Transcatheter closure of ALAF is an option to stabilize the patient as a bridge for surgery. The first reported connection between the aorta and the cardiac chambers was described in 1924 as an incidental finding on autopsy.1Boyd L. A study of four thousand cases of aneurysm of the thoracic aorta.Am J Med Sci. 1924; 168: 654-658Crossref Google Scholar The etiology of aorto-left atrial fistulas (ALAFs) may be (1) secondary to infective endocarditis or aortic dissection; (2) iatrogenic during cardiac catheterization, ablation, or valve replacement; or (3) traumatic or congenital.2Fierro E.A. Sikachi R.R. Agrawal A. Verma I. Ojrzanowski M. Sahni S. Aorto-atrial fistulas: a contemporary review.Cardiol Rev. 2018; 26: 137-144Crossref Scopus (9) Google Scholar The clinical presentation of ALAFs depends on the fistula size and the pressure difference between the aorta and the left atrium (LA).3El Yaman M.M. Ammash N.M. Espinosa R.E. Menon S.C. Cetta F. Successful transcatheter closure of an aorto-left atrial fistula.Congenit Heart Dis. 2007; 2: 446-450Crossref PubMed Scopus (5) Google Scholar Due to the significant difference in pressure between the aorta and LA, a sizable ALAF leads to high LA pressure with persistent pulmonary edema. Immediate diagnosis and treatment are mandatory to avoid mortality.4Thomas M.R. Monaghan M.J. Michalis L.K. Jewitt E.J. Aortoatrial fistulae diagnosed by transthoracic and transesophageal echocardiography: advantages of the transesophageal approach.J Am Soc Echocardiogr. 1993; 6: 21-29Abstract Full Text PDF PubMed Scopus (14) Google Scholar Surgical repair has been the standard treatment; however, percutaneous closure is an alternative. To the best of our knowledge, transcatheter closure of ALAF in the setting of active infective endocarditis as a bridge to surgery has not been reported before. A 49-year-old man with a history of rheumatic heart disease since childhood underwent mechanical mitral valve (MV) replacement 30 years prior. Nine years earlier, he had had another surgery with a mechanical aortic valve (AV) replacement. He had chronic atrial fibrillation that was controlled by medication. He had regular follow-up, with an international normalization rate kept to around 3, and he adhered strictly to his medication regimen. He presented to the emergency room with a history of fever, productive cough, and difficulty breathing for the last 3 days. The patient was tachypneic, 25 breaths/minute, and tachycardic, 110 beats/minute. On auscultation, there was a continuous murmur with maximum intensity at the left sternal border that propagated all over the pericardium. He had another ejection systolic murmur at the right sternal edge that spread to the neck. His arterial blood gases showed hypoxemia and respiratory acidosis. His initial blood test showed mild anemia, elevated white blood cells, and an international normalization rate of 10. The samples for cultures were extracted from the blood, urine, and sputum before starting antibiotics. Bedside transthoracic echocardiography (TTE) revealed a high gradient on the aortic and mitral mechanical prosthesis with questionable mobile masses on both valves. The patient underwent transesophageal echocardiography (TEE), which revealed a large aortic root abscess fistulating to the LA with a large shunt (Figure 1B and Video 1). There was a continuous flow into the LA (Figure 1C, 1D, 1E, Videos 2 and 3), Three dimensional TEE full volume with color showed the flow of ALAF (Video 4). The mean pressure gradient (PG) at the MV was 20 mm Hg (Figure 1F); however, the MV was opening well, so this high gradient was due to high flow from the fistula. There was a systolic reversal in the left upper pulmonary vein (Figure 1G). The left ventricular ejection fraction was 50%. Vegetation was seen attached to the mechanical MV (Figure 2A and Video 5). The mean PG at the mechanical AV was 59 mm Hg (Figure 2B).Figure 2(A) A small vegetation moving through the mechanical MV. (B) The mean PG across the mechanical AV is 59 mm Hg, indicating severe aortic stenosis. (C) The wire passing from the aorta to the fistula to LA during the closure. (D) After the closure of the fistula, there is no more flow to the LA. (E) Improved pulmonary congestion 1 day after fistula closure. (F) Improved pulmonary venous flow; no more systolic reversal immediately after closure. (G) The mean PG at MV decreased to 7 immediately.View Large Image Figure ViewerDownload Hi-res image Download (PPT) All culture results showed no bacterial growth, so antibiotics were modified to cover atypical organisms. The consensus was urgent surgery for double valve replacement. Due to active endocarditis, hemodynamic unstability, and worsening chest condition, the surgery was postponed until the improvement of his pulmonary status. Unfortunately, the patient deteriorated with persistent pulmonary edema and white lung that resisted medical treatment (Figure 1A). He was started on mechanical ventilation. He developed renal impairment with decreased urine output. The treating physician decided to try emergency percutaneous closure of the ALAF as a bridge to surgery. The patient was transferred to the catheterization room for fistula closure with intraprocedural TEE guidance. The procedure was planned by combined arterial access and left atrial access via transseptal puncture. The fistula was first crossed from the aortic side using a multipurpose 5 F catheter and 0.035 F glide wire (Figure 2C and Video 6). The wire was snared using a triple-loop snare (EN Snare), size 45 mm, and exteriorized from the femoral vein, creating an AV loop (Figure 3B and Video 7). A 7 F Torque-Vue sheath crossed from the venous side toward the LA and through the fistula to the ascending aorta. An 8 mm muscular ventricular septal defect device was initially deployed; unfortunately, it trapped one leaflet of the mechanical AV (Figure 3C and Video 8). The device was recaptured, and we considered another type of occlusive device with a smaller aortic skirt. We selected two vascular plugs of size 10 mm (AVP II St. Jude Medical). Two wires were passed through two 6 F sheaths, one from the aorta and one from the LA. The two devices were interlocked together by simultaneous deployment, one deployed through the aortic side and the other deployed through the atrial side (Figure 3D and Video 9). Both devices were released (Figure 3E, 2F and Video 10), and the fistula was closed with no residual flow and no entrapment of any aortic leaflets (Figure 2D and Video 11). Immediately after fistula closure, the pulmonary venous flow improved, with no more systolic reversal (Figure 2F). The mean PG at MV decreased to 7 mm Hg (Figure 2G). Normal coronary angiography was documented at the same time. We recommend having access with two wires across the fistula in case there is a need to add another device; recrossing beside the deployed device is difficult. All deployed devices should be kept connected to their cables until all devices are in place; then they should be released one by one. In this way the risk of device embolization is low. After 1 day, the patient improved dramatically; the chest x-ray showed resolution of pulmonary congestion (Figure 2E), and the renal function went back to normal. On the 19th day, the patient was transferred to the theater, the aortic root was debrided, and a new mechanical aortic prosthesis was implanted successfully. The valve and tissues sent for culture showed no growth for any organism. The MV was functioning well, so the valve was cleaned and left in place. The patient was extubated on the fifth postoperative day. After 2 weeks, the patient was discharged from the hospital in good condition and seen in the outpatient clinic after a few days. At 1-year follow-up, both valves were functioning well (Video 12). We recommend TEE in all patients with prosthetic valves with hemodynamic compromise. TTE can detect fistulous tracts in 50% of cases; however, with TEE, the detection rates increase to 97%.5Hill E.E. Herijgers P. Claus P. Vanderschueren S. Peetermans W.E. Herregods M.C. Abscess in infective endocarditis: the value of transesophageal echocardiography and outcome: a 5-year study.Am Heart J. 2007; 154: 923-928Crossref PubMed Scopus (140) Google Scholar TEE is mandatory during transcatheter closure of the fistula to guide the procedure, decide the size of closure devices, and detect any leaflet entrapment. During AV surgery, injury to the membranous septum and excessive debridement of calcium may lead to ALAF.6Eng M.H. Garcia J.A. Hansgen A. Chen Chan K. Carroll J.D. Percutaneous closure of a para-prosthetic aorto-right ventricular fistula.Int J Cardiol. 2007; 118: e31-e34Abstract Full Text Full Text PDF PubMed Scopus (10) Google Scholar During mitral and tricuspid valve surgeries, deep sutures can lead to ALAF.7Yesin M. Kalcik M. Gursoy M.O. Karakoyun S. Gündüz S. Köksal C. et al.Aorto-left atrial fistula after mitral valve surgery.Echocardiography. 2015; 32: 1446-1448Crossref PubMed Scopus (5) Google Scholar Fierro et al.2Fierro E.A. Sikachi R.R. Agrawal A. Verma I. Ojrzanowski M. Sahni S. Aorto-atrial fistulas: a contemporary review.Cardiol Rev. 2018; 26: 137-144Crossref Scopus (9) Google Scholar collected four cases of intraoperative ALAFs, two cases during MV surgery and two cases during AV surgery; all cases were treated with redo surgery. Fierro et al.2Fierro E.A. Sikachi R.R. Agrawal A. Verma I. Ojrzanowski M. Sahni S. Aorto-atrial fistulas: a contemporary review.Cardiol Rev. 2018; 26: 137-144Crossref Scopus (9) Google Scholar also collected 29 case reports of aortoatrial fistulas in the setting of infective endocarditis; all the cases were treated surgically. Intervalvular fibrosa is an avascular area; any infection with abscess formation can erode this area with fistula formation. Surgery is the standard treatment for ALAF. The surgical intervention consists of repairing the affected aortic segment, replacing the prosthesis, annular debridement in the setting of abscess, and suture of the fistula.8Badak O. Akdeniz B. Aslan O. Kirimli O. Goldeli O. Guneri S. Rare complication of aortic valve replacement: aorto-right atrial fistula.Anadolu Kardiyol Derg. 2003; 3: 373Google Scholar It has been reported that the occurrence of ALAF in the context of infective endocarditis is 1%-2%.9Anguera I. Miro J.M. San Roman J.A. Alarcon A. Anguita M. Almirante B. et al.Periannular complications in infective endocarditis involving prosthetic aortic valves.Am J Cardiol. 2006; 98: 1261-1268Abstract Full Text Full Text PDF PubMed Scopus (100) Google Scholar The bacteria associated with aortoatrial fistulas are the Staphylococcus species in 58% of cases, followed by Streptococcus species in 28%, and Enterococcus species in 7%, with 7% of cases being polymicrobial.10Agrawal A. Amor M.M. Iyer D. Parikh M. Cohen M. Aortico-left atrial fistula: a rare complication of bioprosthetic aortic valve endocarditis secondary to enterococcus faecalis.Case Rep Cardiol. 2015; 2015: 473246Google Scholar Our case showed negative culture endocarditis even from the surgically removed valve. The nature of the pathogen has not been shown to affect prognosis.11Anguera I. Miro J.M. Cabell C.H. Abrutyn E. Fowler V.G. Hoen B. et al.Clinical characteristics and outcome of aortic endocarditis with periannular abscess in the International Collaboration on Endocarditis Merged Database.Am J Cardiol. 2005; 96: 976-981Abstract Full Text Full Text PDF PubMed Scopus (86) Google Scholar Fistulas lead to a high rate of complications, with >60% of patients developing significant heart failure and >40% ending in death.12Ozer N. Deniz A. Atalar E. Aksoyek S. Ovunc K. Kes S. Aorta-right atrial fistula: a rare complication of prosthetic aortic valvular endocarditis.J Am Soc Echocardiogr. 2007; 20: 538.e5-538.e6Abstract Full Text Full Text PDF Scopus (8) Google Scholar Early intervention is indicated to avoid mortality. Usually those patients are unstable and not responding to medical treatment. In our case report, we raise the issue of stabilizing the patient with transcatheter closure of the fistula even in the setting of active infection with abscess and dehiscent valve as a bridge for surgery. The patient improved after plug placement; he was not a surgical candidate prior to plug placement, but after plug placement, he improved to the point that he was a viable surgical candidate. Thus, surgery could never have happened without percutaneous closure first. The review of the literature revealed successful transcatheter closures of aortoatrial fistulas with good short-term outcomes; no long-term data are available. Early diagnosis of ALAFs and immediate management is mandatory to reduce mortality. In hemodynamically unstable patients with an active infection, abscess, and dehiscent valve, transcatheter closure of ALAF is an option to stabilize the patient as a bridge for surgery." @default.
- W2978078464 created "2019-10-10" @default.
- W2978078464 creator A5006081059 @default.
- W2978078464 creator A5017085642 @default.
- W2978078464 creator A5042514786 @default.
- W2978078464 creator A5047936897 @default.
- W2978078464 creator A5050921879 @default.
- W2978078464 creator A5075117674 @default.
- W2978078464 creator A5086602402 @default.
- W2978078464 date "2019-12-01" @default.
- W2978078464 modified "2023-09-27" @default.
- W2978078464 title "Transcatheter Closure of Aorta to Left Atrium Fistula during Active Prosthetic Valve Endocarditis as a Bridge for Surgery: A Case Report" @default.
- W2978078464 cites W1484405354 @default.
- W2978078464 cites W1967195252 @default.
- W2978078464 cites W1979511535 @default.
- W2978078464 cites W1986862201 @default.
- W2978078464 cites W2025035566 @default.
- W2978078464 cites W2055312241 @default.
- W2978078464 cites W2081012509 @default.
- W2978078464 cites W2090115213 @default.
- W2978078464 cites W2461163211 @default.
- W2978078464 cites W2937591999 @default.
- W2978078464 cites W86694643 @default.
- W2978078464 doi "https://doi.org/10.1016/j.case.2019.08.004" @default.
- W2978078464 hasPubMedCentralId "https://www.ncbi.nlm.nih.gov/pmc/articles/6984996" @default.
- W2978078464 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/32002479" @default.
- W2978078464 hasPublicationYear "2019" @default.
- W2978078464 type Work @default.
- W2978078464 sameAs 2978078464 @default.
- W2978078464 citedByCount "1" @default.
- W2978078464 countsByYear W29780784642021 @default.
- W2978078464 crossrefType "journal-article" @default.
- W2978078464 hasAuthorship W2978078464A5006081059 @default.
- W2978078464 hasAuthorship W2978078464A5017085642 @default.
- W2978078464 hasAuthorship W2978078464A5042514786 @default.
- W2978078464 hasAuthorship W2978078464A5047936897 @default.
- W2978078464 hasAuthorship W2978078464A5050921879 @default.
- W2978078464 hasAuthorship W2978078464A5075117674 @default.
- W2978078464 hasAuthorship W2978078464A5086602402 @default.
- W2978078464 hasBestOaLocation W29780784641 @default.
- W2978078464 hasConcept C100776233 @default.
- W2978078464 hasConcept C126322002 @default.
- W2978078464 hasConcept C141071460 @default.
- W2978078464 hasConcept C146834321 @default.
- W2978078464 hasConcept C162324750 @default.
- W2978078464 hasConcept C164705383 @default.
- W2978078464 hasConcept C2775872228 @default.
- W2978078464 hasConcept C2776341189 @default.
- W2978078464 hasConcept C2777615863 @default.
- W2978078464 hasConcept C2779161974 @default.
- W2978078464 hasConcept C2779980429 @default.
- W2978078464 hasConcept C2780714102 @default.
- W2978078464 hasConcept C34447519 @default.
- W2978078464 hasConcept C71924100 @default.
- W2978078464 hasConceptScore W2978078464C100776233 @default.
- W2978078464 hasConceptScore W2978078464C126322002 @default.
- W2978078464 hasConceptScore W2978078464C141071460 @default.
- W2978078464 hasConceptScore W2978078464C146834321 @default.
- W2978078464 hasConceptScore W2978078464C162324750 @default.
- W2978078464 hasConceptScore W2978078464C164705383 @default.
- W2978078464 hasConceptScore W2978078464C2775872228 @default.
- W2978078464 hasConceptScore W2978078464C2776341189 @default.
- W2978078464 hasConceptScore W2978078464C2777615863 @default.
- W2978078464 hasConceptScore W2978078464C2779161974 @default.
- W2978078464 hasConceptScore W2978078464C2779980429 @default.
- W2978078464 hasConceptScore W2978078464C2780714102 @default.
- W2978078464 hasConceptScore W2978078464C34447519 @default.
- W2978078464 hasConceptScore W2978078464C71924100 @default.
- W2978078464 hasIssue "6" @default.
- W2978078464 hasLocation W29780784641 @default.
- W2978078464 hasLocation W29780784642 @default.
- W2978078464 hasLocation W29780784643 @default.
- W2978078464 hasLocation W29780784644 @default.
- W2978078464 hasOpenAccess W2978078464 @default.
- W2978078464 hasPrimaryLocation W29780784641 @default.
- W2978078464 hasRelatedWork W113810927 @default.
- W2978078464 hasRelatedWork W1965866611 @default.
- W2978078464 hasRelatedWork W2013155646 @default.
- W2978078464 hasRelatedWork W2015840096 @default.
- W2978078464 hasRelatedWork W2046824956 @default.
- W2978078464 hasRelatedWork W2081369697 @default.
- W2978078464 hasRelatedWork W2091437571 @default.
- W2978078464 hasRelatedWork W2348809255 @default.
- W2978078464 hasRelatedWork W2403915500 @default.
- W2978078464 hasRelatedWork W3026367711 @default.
- W2978078464 hasVolume "3" @default.
- W2978078464 isParatext "false" @default.
- W2978078464 isRetracted "false" @default.
- W2978078464 magId "2978078464" @default.
- W2978078464 workType "article" @default.