Matches in SemOpenAlex for { <https://semopenalex.org/work/W3000535087> ?p ?o ?g. }
Showing items 1 to 78 of
78
with 100 items per page.
- W3000535087 endingPage "184" @default.
- W3000535087 startingPage "175" @default.
- W3000535087 abstract "Purpose To evaluate the anterior chamber angle status and estimate the intraocular pressure (IOP) in patients with mucopolysaccharidoses (MPSs) type I, II, IV, and VI. Design Prospective cross-sectional study. Methods This study enrolled 27 consecutive MPS patients (8 patients with MPS I, 4 patients with MPS II, 9 patients with MPS IV, and 6 patients with MPS VI) and 20 normal control subjects. Anterior chamber angle status was evaluated by swept-source optical coherence tomography and IOP was estimated by the new-generation tonometer Corvis ST. Results Twelve eyes (6 patients) of 15 eyes (8 patients) with MPS I had narrow angles or peripheral iridocorneal touches together with elevated IOP (80%). Six eyes (3 patients) of 8 eyes (4 patients) with MPS II had plateau iris configuration, but all 8 eyes had normal IOP. All 18 eyes (9 patients) with MPS IV had normal angle structures, but 8 eyes (4 patients) had elevated IOP (44.4%). Nine eyes (5 patients) of 11 eyes (6 patients) with MPS VI had shallow but not closed angles (81.8%). Among these 9 eyes, 5 eyes had elevated IOP, and 4 of these 5 eyes had IOP >30 mm Hg. The trabecular iris angles of MPS types I, II, and VI were smaller than those of MPS type IV and of the control subjects. The angle recess areas of MPS types I and VI were smaller than those of MPS type IV and of the control subjects. Conclusions MPS type I patients are prone to have glaucoma with narrow or closed angles; MPS type II patients tend to have plateau iris; MPS type IV patients are vulnerable to open-angle glaucoma; MPS type VI patients have narrow angles not as close as those of MPS type I. MPS types I, IV, and VI had higher IOP estimates than the control subjects, but only MPS I and IV had higher corrected IOP estimates than the control subjects. The ordinary IOP estimates in MPS VI patients may be falsely high because of clouded corneas and increased corneal rigidity. Swept-source optical coherence tomography helps ophthalmologist investigate the angle structure and the pathophysiology of glaucoma caused by MPS. To evaluate the anterior chamber angle status and estimate the intraocular pressure (IOP) in patients with mucopolysaccharidoses (MPSs) type I, II, IV, and VI. Prospective cross-sectional study. This study enrolled 27 consecutive MPS patients (8 patients with MPS I, 4 patients with MPS II, 9 patients with MPS IV, and 6 patients with MPS VI) and 20 normal control subjects. Anterior chamber angle status was evaluated by swept-source optical coherence tomography and IOP was estimated by the new-generation tonometer Corvis ST. Twelve eyes (6 patients) of 15 eyes (8 patients) with MPS I had narrow angles or peripheral iridocorneal touches together with elevated IOP (80%). Six eyes (3 patients) of 8 eyes (4 patients) with MPS II had plateau iris configuration, but all 8 eyes had normal IOP. All 18 eyes (9 patients) with MPS IV had normal angle structures, but 8 eyes (4 patients) had elevated IOP (44.4%). Nine eyes (5 patients) of 11 eyes (6 patients) with MPS VI had shallow but not closed angles (81.8%). Among these 9 eyes, 5 eyes had elevated IOP, and 4 of these 5 eyes had IOP >30 mm Hg. The trabecular iris angles of MPS types I, II, and VI were smaller than those of MPS type IV and of the control subjects. The angle recess areas of MPS types I and VI were smaller than those of MPS type IV and of the control subjects. MPS type I patients are prone to have glaucoma with narrow or closed angles; MPS type II patients tend to have plateau iris; MPS type IV patients are vulnerable to open-angle glaucoma; MPS type VI patients have narrow angles not as close as those of MPS type I. MPS types I, IV, and VI had higher IOP estimates than the control subjects, but only MPS I and IV had higher corrected IOP estimates than the control subjects. The ordinary IOP estimates in MPS VI patients may be falsely high because of clouded corneas and increased corneal rigidity. Swept-source optical coherence tomography helps ophthalmologist investigate the angle structure and the pathophysiology of glaucoma caused by MPS." @default.
- W3000535087 created "2020-01-23" @default.
- W3000535087 creator A5018655334 @default.
- W3000535087 creator A5025383648 @default.
- W3000535087 creator A5072764187 @default.
- W3000535087 creator A5086460300 @default.
- W3000535087 date "2020-04-01" @default.
- W3000535087 modified "2023-09-28" @default.
- W3000535087 title "Anterior Chamber Angles in Different Types of Mucopolysaccharidoses" @default.
- W3000535087 cites W1942675811 @default.
- W3000535087 cites W1977353587 @default.
- W3000535087 cites W1984545253 @default.
- W3000535087 cites W1985801121 @default.
- W3000535087 cites W1998707365 @default.
- W3000535087 cites W2010472479 @default.
- W3000535087 cites W2012188139 @default.
- W3000535087 cites W2018822016 @default.
- W3000535087 cites W2028317926 @default.
- W3000535087 cites W2040242541 @default.
- W3000535087 cites W2046693574 @default.
- W3000535087 cites W2048083700 @default.
- W3000535087 cites W2053800852 @default.
- W3000535087 cites W2101066852 @default.
- W3000535087 cites W2111000351 @default.
- W3000535087 cites W2114566908 @default.
- W3000535087 cites W2120277028 @default.
- W3000535087 cites W2125123118 @default.
- W3000535087 cites W2144065257 @default.
- W3000535087 cites W2161110724 @default.
- W3000535087 cites W2164020569 @default.
- W3000535087 cites W2335744710 @default.
- W3000535087 cites W2759765051 @default.
- W3000535087 cites W342980 @default.
- W3000535087 doi "https://doi.org/10.1016/j.ajo.2020.01.007" @default.
- W3000535087 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/31945334" @default.
- W3000535087 hasPublicationYear "2020" @default.
- W3000535087 type Work @default.
- W3000535087 sameAs 3000535087 @default.
- W3000535087 citedByCount "7" @default.
- W3000535087 countsByYear W30005350872021 @default.
- W3000535087 countsByYear W30005350872022 @default.
- W3000535087 countsByYear W30005350872023 @default.
- W3000535087 crossrefType "journal-article" @default.
- W3000535087 hasAuthorship W3000535087A5018655334 @default.
- W3000535087 hasAuthorship W3000535087A5025383648 @default.
- W3000535087 hasAuthorship W3000535087A5072764187 @default.
- W3000535087 hasAuthorship W3000535087A5086460300 @default.
- W3000535087 hasConcept C118487528 @default.
- W3000535087 hasConcept C2778527774 @default.
- W3000535087 hasConcept C2781092963 @default.
- W3000535087 hasConcept C2910536731 @default.
- W3000535087 hasConcept C71924100 @default.
- W3000535087 hasConceptScore W3000535087C118487528 @default.
- W3000535087 hasConceptScore W3000535087C2778527774 @default.
- W3000535087 hasConceptScore W3000535087C2781092963 @default.
- W3000535087 hasConceptScore W3000535087C2910536731 @default.
- W3000535087 hasConceptScore W3000535087C71924100 @default.
- W3000535087 hasLocation W30005350871 @default.
- W3000535087 hasLocation W30005350872 @default.
- W3000535087 hasOpenAccess W3000535087 @default.
- W3000535087 hasPrimaryLocation W30005350871 @default.
- W3000535087 hasRelatedWork W1137840535 @default.
- W3000535087 hasRelatedWork W1971004186 @default.
- W3000535087 hasRelatedWork W2042967592 @default.
- W3000535087 hasRelatedWork W2044049238 @default.
- W3000535087 hasRelatedWork W2111980802 @default.
- W3000535087 hasRelatedWork W2405419176 @default.
- W3000535087 hasRelatedWork W2752005099 @default.
- W3000535087 hasRelatedWork W2886435389 @default.
- W3000535087 hasRelatedWork W4375861827 @default.
- W3000535087 hasRelatedWork W642445530 @default.
- W3000535087 hasVolume "212" @default.
- W3000535087 isParatext "false" @default.
- W3000535087 isRetracted "false" @default.
- W3000535087 magId "3000535087" @default.
- W3000535087 workType "article" @default.