Matches in SemOpenAlex for { <https://semopenalex.org/work/W3087380049> ?p ?o ?g. }
Showing items 1 to 62 of
62
with 100 items per page.
- W3087380049 endingPage "166" @default.
- W3087380049 startingPage "165" @default.
- W3087380049 abstract "Central MessageWATCHMAN device failure requires a range of surgical approaches described in this series. Long-term data and additional patient and operative details would help define optimal surgical management.See Article page 160. WATCHMAN device failure requires a range of surgical approaches described in this series. Long-term data and additional patient and operative details would help define optimal surgical management. See Article page 160. In this edition of JTCVS Techniques, Palmer and colleagues1Palmer S. Romano M.A. Bolling S.F. Fukahara S. Surgical strategies for a failed watchman device.J Thorac Cardiovasc Surg Tech. 2020; 4: 160-164Google Scholar present a series of 5 patients with failed WATCHMAN (Boston Scientific, Plymouth, Minn) devices requiring surgical intervention. WATCHMAN device failure is often treated with anticoagulation to prevent thrombotic complications of a malpositioned device and to reduce the stroke risk associated with the patient's atrial fibrillation. Device failure in this series was due to peri-device leak, dislodgement, or thrombus formation, and all patients developed bleeding complications from anticoagulation. Operative indications are not exactly clear, but it appears that 3 patients had bleeding complications, 1 of whom had multiple thrombi, and 2 patients had severe mitral regurgitation (MR). In 3 patients, the device was explanted and the left atrial appendage (LAA) excluded with either suture or with the AtriClip (AtriCure Inc, Mason, Ohio). In 1 patient, the device remained and the LAA was excluded with the AtriClip and in another patient the device was excluded with a pericardial patch. LAA occlusion was 100% successful—there was no flow or residual stump of the LAA; all patients underwent a maze procedure at the time of operation. Several questions arise from this case series. First, why did 3 of these patients require valve replacements? Did the WATCHMAN device cause these valve pathologies and if not, shouldn't these patients have been referred for surgical valve treatment and maze as the initial treatment? If the valve pathologies were caused by the device, it would be interesting to see on echocardiography how the device caused MR or aortic valve disease; there are case reports in the literature of MR and aortic stenosis caused by the WATCHMAN device.2Deng H. Liao H. Liu Y. Chen S. Xue Y. Zhan X. et al.Acute heart failure caused by dislocation of a WATCHMAN left atrial appendage occluder.JACC Cardiovasc Interv. 2016; 9: e97-e99Crossref PubMed Scopus (9) Google Scholar,3El-Gabry M. Shehada S.E. Wendt D. Mourad F. Emergent surgical removal of a migrated left atrial appendage occluder.Eur J Cardiothorac Surg. 2018; 54: 191-192Crossref PubMed Scopus (7) Google Scholar Second, while the immediate postoperative echocardiography findings are promising, we know that most failures occur late.4Lee R. Vassallo P. Kruse J. Malaisrie S.C. Rigolin V. Andrei A.C. et al.A randomized, prospective pilot comparison of 3 atrial appendage elimination techniques: internal ligation, stapled excision, and surgical excision.J Thorac Cardiovasc Surg. 2016; 152: 1075-1080Abstract Full Text Full Text PDF PubMed Scopus (74) Google Scholar This series would be strengthened by long-term imaging confirmation of LAA occlusion. Third, 2 of the patients remained on anticoagulation for 6 months; this seems unusual since both of the patients had preoperative bleeding complications. If the anticoagulation is for prevention of thromboembolism after bioprosthetic valve replacement, then why was one of the patients on rivaroxaban, which is not the recommended anticoagulant, and both were anticoagulated for 6 months, which is on the longer end of the recommended 3-6-months?5Nishimura R.A. Otto C.M. Bonow R.O. Carabello B.A. Erwin III, J.P. Fleisher L.A. et al.2017 AHA/ACC focused update of the 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association task force on clinical practice guidelines.J Am Coll Cardiol. 2017; 70: 252-289Crossref PubMed Scopus (1812) Google Scholar Finally, the authors include a supplemental video, which nicely shows a video-assisted thoracoscopic surgery technique for LAA exclusion with the AtriClip while keeping the device in place. This approach, as the authors comment in their conclusions, works well when there is no atrial thrombus or protrusion of the device into the left atrium. But when those criteria are not met, a robotic or right mini-thoracotomy approach could be equally effective while providing patients with the benefit of a minimally invasive operation. This series is an excellent summary of the types of WATCHMAN device failures and varied surgical approaches to address these failures and eliminate the LAA as a source of stroke. We encourage the authors to elaborate on this series with more patient and operative details to further understand the optimal surgical management of these complex WATCHMAN device failures. Surgical strategies for a failed Watchman deviceJTCVS TechniquesVol. 4PreviewTranscatheter closure of the left atrial appendage (LAA) using a Watchman device (Boston Scientific, Plymouth, Minn) is an approved alternative to oral anticoagulation to reduce the risk of stroke in patients with atrial fibrillation that are considered at high risk for bleeding complications.1 Device malposition and/or incomplete LAA seal are known inherent modes of device failure. These events may be underreported, because most of these nonfatal complications can be managed by continued antithrombotic therapy. Full-Text PDF Open Access" @default.
- W3087380049 created "2020-09-25" @default.
- W3087380049 creator A5005972665 @default.
- W3087380049 creator A5008410969 @default.
- W3087380049 date "2020-12-01" @default.
- W3087380049 modified "2023-10-01" @default.
- W3087380049 title "Commentary: Watch out for WATCHMAN device failures" @default.
- W3087380049 cites W2398389519 @default.
- W3087380049 cites W2467643486 @default.
- W3087380049 cites W2596816418 @default.
- W3087380049 cites W2793264827 @default.
- W3087380049 cites W3049705359 @default.
- W3087380049 doi "https://doi.org/10.1016/j.xjtc.2020.09.001" @default.
- W3087380049 hasPubMedCentralId "https://www.ncbi.nlm.nih.gov/pmc/articles/8306117" @default.
- W3087380049 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/34317998" @default.
- W3087380049 hasPublicationYear "2020" @default.
- W3087380049 type Work @default.
- W3087380049 sameAs 3087380049 @default.
- W3087380049 citedByCount "1" @default.
- W3087380049 countsByYear W30873800492023 @default.
- W3087380049 crossrefType "journal-article" @default.
- W3087380049 hasAuthorship W3087380049A5005972665 @default.
- W3087380049 hasAuthorship W3087380049A5008410969 @default.
- W3087380049 hasBestOaLocation W30873800491 @default.
- W3087380049 hasConcept C127413603 @default.
- W3087380049 hasConcept C141071460 @default.
- W3087380049 hasConcept C164705383 @default.
- W3087380049 hasConcept C2779161974 @default.
- W3087380049 hasConcept C2780645631 @default.
- W3087380049 hasConcept C2781362458 @default.
- W3087380049 hasConcept C71924100 @default.
- W3087380049 hasConcept C78519656 @default.
- W3087380049 hasConceptScore W3087380049C127413603 @default.
- W3087380049 hasConceptScore W3087380049C141071460 @default.
- W3087380049 hasConceptScore W3087380049C164705383 @default.
- W3087380049 hasConceptScore W3087380049C2779161974 @default.
- W3087380049 hasConceptScore W3087380049C2780645631 @default.
- W3087380049 hasConceptScore W3087380049C2781362458 @default.
- W3087380049 hasConceptScore W3087380049C71924100 @default.
- W3087380049 hasConceptScore W3087380049C78519656 @default.
- W3087380049 hasLocation W30873800491 @default.
- W3087380049 hasLocation W30873800492 @default.
- W3087380049 hasLocation W30873800493 @default.
- W3087380049 hasOpenAccess W3087380049 @default.
- W3087380049 hasPrimaryLocation W30873800491 @default.
- W3087380049 hasRelatedWork W1967841144 @default.
- W3087380049 hasRelatedWork W2018480046 @default.
- W3087380049 hasRelatedWork W2064495796 @default.
- W3087380049 hasRelatedWork W2319489406 @default.
- W3087380049 hasRelatedWork W2333279585 @default.
- W3087380049 hasRelatedWork W2603808924 @default.
- W3087380049 hasRelatedWork W2763816051 @default.
- W3087380049 hasRelatedWork W2793053827 @default.
- W3087380049 hasRelatedWork W2889073610 @default.
- W3087380049 hasRelatedWork W4207059483 @default.
- W3087380049 hasVolume "4" @default.
- W3087380049 isParatext "false" @default.
- W3087380049 isRetracted "false" @default.
- W3087380049 magId "3087380049" @default.
- W3087380049 workType "article" @default.