Matches in SemOpenAlex for { <https://semopenalex.org/work/W3128606322> ?p ?o ?g. }
Showing items 1 to 78 of
78
with 100 items per page.
- W3128606322 endingPage "1086" @default.
- W3128606322 startingPage "1086" @default.
- W3128606322 abstract "Sir, We would like to share a case series of four morbidly obese patients with traumatic rib fractures requiring respiratory support in the intensive care unit (ICU) and they received erector spinae plane (ESP) block[1] as analgesic adjunct. They were males with median age (interquartile range, IQR), 56 (42–61) years and median body mass index, BMI (IQR) 35.2 (33.0–36.9) kg/m2. They had sustained polytrauma [Table 1] secondary to motor vehicle accidents with multilevel rib fractures and other injuries. They also had multiple comorbidities, required oxygen therapy with non-invasive ventilatory (NIV) support, therefore, being closely monitored in ICU. They received multimodal analgesia regime—intravenous patient-controlled analgesia (PCA) morphine, regular doses of paracetamol, tramadol plus nonsteroidal anti inflammatory drugs (NSAIDs) or coxib since hospital admission. Despite the above analgesic regime, they still experienced severes pain. The median pain scores using numerical rating scale (NRS) were 6.5/10 (IQR 5.25–7.75) at rest and 9/10 (IQR 7.25–10) during movement. The mean daily morphine consumption prior to block was 48 mg (±8 mg). ESP block was given on day 2 of ICU admission because of unsatisfactory pain control, poor cough effort with difficulty to perform chest physiotherapy and requiring NIV support.Table 1: Case descriptionThe blocks were performed using a 10-5 MHz 38 mm linear probe (Sonosite M-Turbo, Bothell, Washington, USA) and an 80 mm, 18-gauge Tuohy epidural needle (Perifix® Filter set, BBraun, Melsungen, Germany) with in-plane needling technique. Patients were placed either in sitting or lateral position, adjusted according to their comfort level as they had multiple injuries and skin wound affecting the positioning. The transverse process of the 3rd or 4th thoracic vertebra was identified. Muscle layers of trapezius, rhomboids major, and erector spinae were identified, and the fascial plane beneath the erector spinae muscle was entered with the Tuohy epidural needle inserted from cranial to caudal direction. The needle placement was confirmed with pumping effect within the fascial plane following hydrodissection and small boluses of local anaesthetic. A total bolus of 40 ml of ropivacaine 0.375% was delivered within the fascial plane and an indwelling Perifix epidural catheter was threaded-in and anchored with 4 cm tip in the fascial plane with transparent film dressing (3M™ Tegaderm™, Maplewood, Minnesota, USA) [Figure 1]. ESP block is a fascial plane block which relies on high volume low concentration local anaesthetic to exert its analgesic efficacy. Luftig et al.[2] recommended a 40 ml local anaesthetic regime for patient above 70 kg in unilateral ESP block. All patients experienced significant pain reduction within 30 min after the block [Figure 1]. A continuous infusion of 8 ml/h ropivacaine 0.2% was run with intermittent bolus of 10 ml ropivacaine 0.2% every 12 h. The intermittent bolus was delivered manually by a trained staff nurse to avoid patient confusion with the PCA morphine device plus no available programmed infusion pump. The median pain scores after ESP block were 2/10 (IQR 2 – 2) at rest and 4/10 (IQR 4.0–4.75) during movement. The pain score remained mild to moderate over the next few days. As patients also had other injuries [Table 1], it would be difficult to achieve zero pain score although other injury sites were not the predominant pain area. Therefore, the mean daily morphine consumption only reduced gradually after ESP block [Table 1]. The median length of ICU stays were 6.5 days (IQR 6–7.75). The median duration of NIV support was 2.5 days (IQR 2–3).Figure 1: (a) Poor sonoanatomy of the erector spinae plane (ESP) despite optimal adjustment of the ultrasound settings, probe selection and manipulation. The ESP is located deeper (>4 cm). The 18G Tuohy needle is vaguely seen in the trajectory pathway. (b) Sonoanatomy of ESP with catheter in a thin lady (unrelated case), a stark difference of sonoanatomy between a lean and an obese patient. (c) Patient B is on non-invasive ventilator support. Inset – The monitors showed drastic reduction of blood pressure after the ESP block because his pain was alleviated and stress response attenuatedTraumatic rib fractures are very painful. Inadequate pain control would impair breathing, adequate coughing with clearance of pulmonary secretions and compliance with chest physiotherapy. Consequently, patient would be at risk of secondary pulmonary complications, that is, atelectasis, pneumonia, respiratory failure, and the need for respiratory support. Effective analgesia may help to improve a patient's respiratory mechanics and to avoid intubation of the trachea for ventilatory support and therefore may dramatically alter the course of recovery. Multimodal systemic analgesics with intravenous patient-controlled opioid has been the mainstay of pain management and they are usually sufficient for healthy individuals with one to two fractured ribs.[3] However, for more than three to four fractured ribs, studies and experience have reaffirmed that regional techniques like thoracic epidural, thoracic paravertebral, serratus anterior plane, and intercostal blocks provide superior analgesia.[34] Regional techniques are particularly useful in elderly patients, patients with multiple rib fractures, and in patients with severe pain or compromised pulmonary function.[3] However, epidural analgesia and paravertebral block may not be feasible in the presence of anti-coagulation, multisystem trauma, haemodynamic instability, or in patients unable to be optimally positioned.[3] ESP block was the most feasible regional technique in our case series because patients were obese. The quality of the ESP sonoanatomy was already below average and located deeper (>4 cm) [Figure 1] despite optimal adjustment of the ultrasound settings (knob), probe selection, and probe manipulation. The paravertebral space which is anatomically located deeper than ESP could not be properly visualised during scout scan, therefore we did not attempt paravertebral blocks. A literature review showed that there are three case reports[567] and one retrospective cohort study[8] about the use of ESP block for pain relief in rib fractures. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest. Acknowledgement We thank Dr Siew Gee Ho for helping us to trace the clinical progress and outcome of the above-mentioned cases." @default.
- W3128606322 created "2021-02-15" @default.
- W3128606322 creator A5013055549 @default.
- W3128606322 creator A5015673909 @default.
- W3128606322 creator A5033646461 @default.
- W3128606322 creator A5073141414 @default.
- W3128606322 date "2020-01-01" @default.
- W3128606322 modified "2023-09-26" @default.
- W3128606322 title "Erector spinae plane block as analgesic adjunct for traumatic rib fractures in intensive care unit" @default.
- W3128606322 cites W2508371222 @default.
- W3128606322 cites W2588040705 @default.
- W3128606322 cites W2780912217 @default.
- W3128606322 cites W2787934635 @default.
- W3128606322 cites W2789775862 @default.
- W3128606322 cites W2884413969 @default.
- W3128606322 cites W2912550060 @default.
- W3128606322 cites W3010738254 @default.
- W3128606322 doi "https://doi.org/10.4103/ija.ija_1110_20" @default.
- W3128606322 hasPubMedCentralId "https://www.ncbi.nlm.nih.gov/pmc/articles/7852452" @default.
- W3128606322 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/33542581" @default.
- W3128606322 hasPublicationYear "2020" @default.
- W3128606322 type Work @default.
- W3128606322 sameAs 3128606322 @default.
- W3128606322 citedByCount "3" @default.
- W3128606322 countsByYear W31286063222022 @default.
- W3128606322 countsByYear W31286063222023 @default.
- W3128606322 crossrefType "journal-article" @default.
- W3128606322 hasAuthorship W3128606322A5013055549 @default.
- W3128606322 hasAuthorship W3128606322A5015673909 @default.
- W3128606322 hasAuthorship W3128606322A5033646461 @default.
- W3128606322 hasAuthorship W3128606322A5073141414 @default.
- W3128606322 hasBestOaLocation W31286063221 @default.
- W3128606322 hasConcept C119060515 @default.
- W3128606322 hasConcept C126322002 @default.
- W3128606322 hasConcept C141071460 @default.
- W3128606322 hasConcept C1862650 @default.
- W3128606322 hasConcept C2776376669 @default.
- W3128606322 hasConcept C2777389121 @default.
- W3128606322 hasConcept C2779777798 @default.
- W3128606322 hasConcept C2780221984 @default.
- W3128606322 hasConcept C2780820201 @default.
- W3128606322 hasConcept C42219234 @default.
- W3128606322 hasConcept C71924100 @default.
- W3128606322 hasConceptScore W3128606322C119060515 @default.
- W3128606322 hasConceptScore W3128606322C126322002 @default.
- W3128606322 hasConceptScore W3128606322C141071460 @default.
- W3128606322 hasConceptScore W3128606322C1862650 @default.
- W3128606322 hasConceptScore W3128606322C2776376669 @default.
- W3128606322 hasConceptScore W3128606322C2777389121 @default.
- W3128606322 hasConceptScore W3128606322C2779777798 @default.
- W3128606322 hasConceptScore W3128606322C2780221984 @default.
- W3128606322 hasConceptScore W3128606322C2780820201 @default.
- W3128606322 hasConceptScore W3128606322C42219234 @default.
- W3128606322 hasConceptScore W3128606322C71924100 @default.
- W3128606322 hasIssue "12" @default.
- W3128606322 hasLocation W31286063221 @default.
- W3128606322 hasLocation W31286063222 @default.
- W3128606322 hasLocation W31286063223 @default.
- W3128606322 hasLocation W31286063224 @default.
- W3128606322 hasOpenAccess W3128606322 @default.
- W3128606322 hasPrimaryLocation W31286063221 @default.
- W3128606322 hasRelatedWork W2009291816 @default.
- W3128606322 hasRelatedWork W2111096735 @default.
- W3128606322 hasRelatedWork W2130487363 @default.
- W3128606322 hasRelatedWork W2370432291 @default.
- W3128606322 hasRelatedWork W2389999617 @default.
- W3128606322 hasRelatedWork W4206871862 @default.
- W3128606322 hasRelatedWork W4225271073 @default.
- W3128606322 hasRelatedWork W4254262659 @default.
- W3128606322 hasRelatedWork W4287435042 @default.
- W3128606322 hasRelatedWork W2181852399 @default.
- W3128606322 hasVolume "64" @default.
- W3128606322 isParatext "false" @default.
- W3128606322 isRetracted "false" @default.
- W3128606322 magId "3128606322" @default.
- W3128606322 workType "article" @default.