Matches in SemOpenAlex for { <https://semopenalex.org/work/W3137168460> ?p ?o ?g. }
Showing items 1 to 77 of
77
with 100 items per page.
- W3137168460 endingPage "S110" @default.
- W3137168460 startingPage "S110" @default.
- W3137168460 abstract "PurposeTo evaluate the effect of the new donor heart allocation system on waitlist and post-transplant (HTx) mortality in candidates listed with a durable left ventricular assist device (LVAD).MethodsThe United Network for Organ Sharing (UNOS) database was queried for adults listed for heart transplantation with a durable LVAD between October 2015 and August 2020. Fine-Gray competing risks analysis was utilized to examine the association between implementation of the new donor heart allocation system and removal from the waitlist due to death or worsening clinical condition among candidates listed with a durable LVAD. Post-HTx survival was examined using Kaplan-Meier estimates and Cox proportional hazards analysis.Results3399 (67.3) of the 5052 candidates included in this study were listed under the old system. Listing under the new system provided significant protection from waitlist removal due to death or clinical deterioration within 365 days (HR: 0.70, 95% CI: 0.53-0.91, p=0.01) of listing (Figure A). Of these candidates, HTx recipients under the new system were more likely to experience death or retransplant within 365 days of HTx (HR: 1.84, 95% CI 1.42-2.40, p<0.01) (Figure B). Age at and gender distribution at HTx were similar between groups, although those transplanted under the new system had significantly higher body mass index (29.5 vs. 28.6 kg/m2, p<0.01). Ischemic time under the new system was 3.4 hours (interquartile range (IQR): 2.8-4.1 hours) vs. 3.1 hours (IQR: 2.3-3.7 hours) under the old system (p<0.01). The proportion of mechanically ventilated recipients were similar (0.4 vs. 0.4%, p=0.94).ConclusionCandidates listed with a durable LVAD experience less waitlist morbidity and mortality under the new system compared to the old system, although post-HTx survival may suffer. This could be representative of wider regional sharing of organs and associated increases in ischemic time. To evaluate the effect of the new donor heart allocation system on waitlist and post-transplant (HTx) mortality in candidates listed with a durable left ventricular assist device (LVAD). The United Network for Organ Sharing (UNOS) database was queried for adults listed for heart transplantation with a durable LVAD between October 2015 and August 2020. Fine-Gray competing risks analysis was utilized to examine the association between implementation of the new donor heart allocation system and removal from the waitlist due to death or worsening clinical condition among candidates listed with a durable LVAD. Post-HTx survival was examined using Kaplan-Meier estimates and Cox proportional hazards analysis. 3399 (67.3) of the 5052 candidates included in this study were listed under the old system. Listing under the new system provided significant protection from waitlist removal due to death or clinical deterioration within 365 days (HR: 0.70, 95% CI: 0.53-0.91, p=0.01) of listing (Figure A). Of these candidates, HTx recipients under the new system were more likely to experience death or retransplant within 365 days of HTx (HR: 1.84, 95% CI 1.42-2.40, p<0.01) (Figure B). Age at and gender distribution at HTx were similar between groups, although those transplanted under the new system had significantly higher body mass index (29.5 vs. 28.6 kg/m2, p<0.01). Ischemic time under the new system was 3.4 hours (interquartile range (IQR): 2.8-4.1 hours) vs. 3.1 hours (IQR: 2.3-3.7 hours) under the old system (p<0.01). The proportion of mechanically ventilated recipients were similar (0.4 vs. 0.4%, p=0.94). Candidates listed with a durable LVAD experience less waitlist morbidity and mortality under the new system compared to the old system, although post-HTx survival may suffer. This could be representative of wider regional sharing of organs and associated increases in ischemic time." @default.
- W3137168460 created "2021-03-29" @default.
- W3137168460 creator A5003849380 @default.
- W3137168460 creator A5021115713 @default.
- W3137168460 creator A5039759042 @default.
- W3137168460 creator A5051659983 @default.
- W3137168460 creator A5057625673 @default.
- W3137168460 creator A5060658296 @default.
- W3137168460 creator A5071155926 @default.
- W3137168460 creator A5079847443 @default.
- W3137168460 creator A5090346613 @default.
- W3137168460 date "2021-04-01" @default.
- W3137168460 modified "2023-09-27" @default.
- W3137168460 title "Effect of the New Donor Heart Allocation System on Waitlist and Post-Transplant Mortality in Candidates and Recipients with a Durable Left Ventricular Assist Device" @default.
- W3137168460 doi "https://doi.org/10.1016/j.healun.2021.01.354" @default.
- W3137168460 hasPublicationYear "2021" @default.
- W3137168460 type Work @default.
- W3137168460 sameAs 3137168460 @default.
- W3137168460 citedByCount "0" @default.
- W3137168460 crossrefType "journal-article" @default.
- W3137168460 hasAuthorship W3137168460A5003849380 @default.
- W3137168460 hasAuthorship W3137168460A5021115713 @default.
- W3137168460 hasAuthorship W3137168460A5039759042 @default.
- W3137168460 hasAuthorship W3137168460A5051659983 @default.
- W3137168460 hasAuthorship W3137168460A5057625673 @default.
- W3137168460 hasAuthorship W3137168460A5060658296 @default.
- W3137168460 hasAuthorship W3137168460A5071155926 @default.
- W3137168460 hasAuthorship W3137168460A5079847443 @default.
- W3137168460 hasAuthorship W3137168460A5090346613 @default.
- W3137168460 hasBestOaLocation W31371684601 @default.
- W3137168460 hasConcept C119060515 @default.
- W3137168460 hasConcept C126322002 @default.
- W3137168460 hasConcept C164705383 @default.
- W3137168460 hasConcept C2776342676 @default.
- W3137168460 hasConcept C2778198053 @default.
- W3137168460 hasConcept C2778774980 @default.
- W3137168460 hasConcept C2778849806 @default.
- W3137168460 hasConcept C2779609443 @default.
- W3137168460 hasConcept C2909794420 @default.
- W3137168460 hasConcept C2910855829 @default.
- W3137168460 hasConcept C2911091166 @default.
- W3137168460 hasConcept C50382708 @default.
- W3137168460 hasConcept C71924100 @default.
- W3137168460 hasConceptScore W3137168460C119060515 @default.
- W3137168460 hasConceptScore W3137168460C126322002 @default.
- W3137168460 hasConceptScore W3137168460C164705383 @default.
- W3137168460 hasConceptScore W3137168460C2776342676 @default.
- W3137168460 hasConceptScore W3137168460C2778198053 @default.
- W3137168460 hasConceptScore W3137168460C2778774980 @default.
- W3137168460 hasConceptScore W3137168460C2778849806 @default.
- W3137168460 hasConceptScore W3137168460C2779609443 @default.
- W3137168460 hasConceptScore W3137168460C2909794420 @default.
- W3137168460 hasConceptScore W3137168460C2910855829 @default.
- W3137168460 hasConceptScore W3137168460C2911091166 @default.
- W3137168460 hasConceptScore W3137168460C50382708 @default.
- W3137168460 hasConceptScore W3137168460C71924100 @default.
- W3137168460 hasIssue "4" @default.
- W3137168460 hasLocation W31371684601 @default.
- W3137168460 hasOpenAccess W3137168460 @default.
- W3137168460 hasPrimaryLocation W31371684601 @default.
- W3137168460 hasRelatedWork W1978239102 @default.
- W3137168460 hasRelatedWork W1979506420 @default.
- W3137168460 hasRelatedWork W1999487197 @default.
- W3137168460 hasRelatedWork W2070530429 @default.
- W3137168460 hasRelatedWork W2140839992 @default.
- W3137168460 hasRelatedWork W2207720790 @default.
- W3137168460 hasRelatedWork W2413574118 @default.
- W3137168460 hasRelatedWork W2801303677 @default.
- W3137168460 hasRelatedWork W2979665012 @default.
- W3137168460 hasRelatedWork W48693560 @default.
- W3137168460 hasVolume "40" @default.
- W3137168460 isParatext "false" @default.
- W3137168460 isRetracted "false" @default.
- W3137168460 magId "3137168460" @default.
- W3137168460 workType "article" @default.