Matches in SemOpenAlex for { <https://semopenalex.org/work/W3147478113> ?p ?o ?g. }
Showing items 1 to 67 of
67
with 100 items per page.
- W3147478113 endingPage "89" @default.
- W3147478113 startingPage "88" @default.
- W3147478113 abstract "•Bladder cancer patients who are unsuitable for standard radical treatments present a large unfulfilled clinical need.•Hypofractionated RT can be an appropriate solution for these patients; however organ movement and changes in bladder filling is important obstacle for such treatment strategies.•The only way to overcome this obstacle is that using online adaptive image-guided RT.•There is need of new studies evaluating the role of MRgRT for bladder cancer patients. We read with great interest the article written by Hunt et al. [[1]Hunt A. Hanson I. Dunlop A. Barnes H. Bower L. Chick J. et al.Feasibility of magnetic resonance guided radiotherapy for the treatment of bladder cancer.Clin Transl Radiat Oncol. 2020; 25: 46-51Abstract Full Text Full Text PDF PubMed Scopus (8) Google Scholar]. We encourage their efforts in sharing their initial experience of whole bladder magnetic resonance image-guide radiotherapy (MRgRT) using the 1.5 Tesla MR-Linac Elekta Unity (Elekta AB, Stockholm, Sweden). In their initial experience they emphasized that ultra hypofractionated radiotherapy (RT) was feasible and safe with acceptable toxicity profile. Their prospective study has now been extended to include radical patients receiving daily whole bladder RT to a total dose of 55 Gy delivered in 20 fractions. Current study is important, because to the best of our knowledge current study is the first one reporting the role of MRgRT for bladder cancer patients using ultra hypofractionated RT. Muscle invasive bladder cancer patients who are unfit and unsuitable for standard radical treatment with cystectomy or daily RT present a large unfulfilled clinical need [[2]Hafeez S. Patel E. Webster A. Warren-Oseni K. Hansen V. McNair H. et al.Protocol for hypofractionated adaptive radiotherapy to the bladder within a multicentre phase II randomised trial: radiotherapy planning and delivery guidance.BMJ Open. 2020; 10: e037134https://doi.org/10.1136/bmjopen-2020-037134Crossref PubMed Scopus (12) Google Scholar]. Hypofractionated RT can be an appropriate solution for these patients; however organ movement and changes in bladder filling is important obstacle for such treatment strategies. The only way to overcome this obstacle is that using online adaptive image-guided RT, wherein MRgRT is the state of art for the image-guided RT. We have limited experience in using 1.5 Tesla MR-Linac Elekta Unity (Elekta AB, Stockholm, Sweden), since June 2020. The current interesting article encouraged us to treat a bladder cancer patient who is unsuitable for radical surgery or long-term chemo-radiotherapy (CRT) due to comorbidities. We have couple of concerns regarding this article, and the response to these concerns will be paving the way to MRgRT for the patients suffering from bladder cancer. The dose constraints for planning target volume (PTV) was not mentioned clearly and there is a conflict between the manuscript and the supplementary material. The authors emphasized that the prescription dose (PTV D50%) was 36 Gy in six fractions delivered weekly; 30 Gy in five fractions was used for local symptom palliation in those with metastatic disease. Moreover, the acceptable clinical target volume (CTV) coverage was as defined 95% of CTV receiving >95% of prescribed dose. However in the supplementary material they defined the same constraint for PTV instead of CTV. We also calculated our patient’s treatment plan using the dose constraints; however it is impossible to obtain the same value for both CTV, and PTV. Therefore we wonder the dose constraints for PTV as well. Second, the bladder filling during the treatment period of MRgRT, which is relatively longer than conventional fractionation RT, as we experienced during prostate cancer patients treatment with MRgRT, is an important obstacle. Therefore we wonder how the authors did define the margins from CTV to PTV. As far as we can understand from the article that, they did not have any difficulty about bladder filling during the treatment. Because they emphasized that median intra-fraction CTV change (a surrogate for bladder filling as determined by change in volume between MRIsession and MRIpost) was 30 cc (range 2–82 cc). However they also underlined that the median CTV as determined on MRI session was 107 cc (range 60–243 cc). In the current valuable study no protocol was adopted for bladder preparation, therefore we wonder if the authors suggest us to do this. Third, during the treatment planning the authors used 2% per plan with respect to the statistical uncertainty. We wonder why the authors chose 2%, instead of 1%. Last but not least, their prospective study has now been extended to include radical patients receiving daily whole bladder RT to a dosage 55 Gy in 20 fractions, as was mentioned in the article. We wonder the reason for choosing such dose extension. We consider that the authors’ response to the above comments would clarify their interesting and valuable work. Clarification of the aforementioned issues will be helpful for a better understanding role of ultra hypofractionated RT using MRgRT for bladder cancer patients and will enlighten our future perspective. The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper." @default.
- W3147478113 created "2021-04-13" @default.
- W3147478113 creator A5059029067 @default.
- W3147478113 creator A5067017471 @default.
- W3147478113 creator A5070958553 @default.
- W3147478113 creator A5080860190 @default.
- W3147478113 date "2021-05-01" @default.
- W3147478113 modified "2023-09-23" @default.
- W3147478113 title "Comment on Hunt et al, “Feasibility of magnetic resonance guided radiotherapy for the treatment of bladder cancer”" @default.
- W3147478113 cites W3030022471 @default.
- W3147478113 cites W3084585536 @default.
- W3147478113 doi "https://doi.org/10.1016/j.ctro.2021.03.008" @default.
- W3147478113 hasPubMedCentralId "https://www.ncbi.nlm.nih.gov/pmc/articles/8065181" @default.
- W3147478113 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/33912694" @default.
- W3147478113 hasPublicationYear "2021" @default.
- W3147478113 type Work @default.
- W3147478113 sameAs 3147478113 @default.
- W3147478113 citedByCount "0" @default.
- W3147478113 crossrefType "journal-article" @default.
- W3147478113 hasAuthorship W3147478113A5059029067 @default.
- W3147478113 hasAuthorship W3147478113A5067017471 @default.
- W3147478113 hasAuthorship W3147478113A5070958553 @default.
- W3147478113 hasAuthorship W3147478113A5080860190 @default.
- W3147478113 hasBestOaLocation W31474781131 @default.
- W3147478113 hasConcept C121608353 @default.
- W3147478113 hasConcept C126322002 @default.
- W3147478113 hasConcept C126838900 @default.
- W3147478113 hasConcept C143409427 @default.
- W3147478113 hasConcept C19527891 @default.
- W3147478113 hasConcept C2775910329 @default.
- W3147478113 hasConcept C2780352672 @default.
- W3147478113 hasConcept C2989005 @default.
- W3147478113 hasConcept C509974204 @default.
- W3147478113 hasConcept C535046627 @default.
- W3147478113 hasConcept C71924100 @default.
- W3147478113 hasConceptScore W3147478113C121608353 @default.
- W3147478113 hasConceptScore W3147478113C126322002 @default.
- W3147478113 hasConceptScore W3147478113C126838900 @default.
- W3147478113 hasConceptScore W3147478113C143409427 @default.
- W3147478113 hasConceptScore W3147478113C19527891 @default.
- W3147478113 hasConceptScore W3147478113C2775910329 @default.
- W3147478113 hasConceptScore W3147478113C2780352672 @default.
- W3147478113 hasConceptScore W3147478113C2989005 @default.
- W3147478113 hasConceptScore W3147478113C509974204 @default.
- W3147478113 hasConceptScore W3147478113C535046627 @default.
- W3147478113 hasConceptScore W3147478113C71924100 @default.
- W3147478113 hasLocation W31474781131 @default.
- W3147478113 hasLocation W31474781132 @default.
- W3147478113 hasOpenAccess W3147478113 @default.
- W3147478113 hasPrimaryLocation W31474781131 @default.
- W3147478113 hasRelatedWork W1973041883 @default.
- W3147478113 hasRelatedWork W1987212190 @default.
- W3147478113 hasRelatedWork W2033515852 @default.
- W3147478113 hasRelatedWork W2038776230 @default.
- W3147478113 hasRelatedWork W2079205857 @default.
- W3147478113 hasRelatedWork W2120921122 @default.
- W3147478113 hasRelatedWork W2164361265 @default.
- W3147478113 hasRelatedWork W2728560941 @default.
- W3147478113 hasRelatedWork W2993165969 @default.
- W3147478113 hasRelatedWork W3136529388 @default.
- W3147478113 hasVolume "28" @default.
- W3147478113 isParatext "false" @default.
- W3147478113 isRetracted "false" @default.
- W3147478113 magId "3147478113" @default.
- W3147478113 workType "article" @default.