Matches in SemOpenAlex for { <https://semopenalex.org/work/W3166783986> ?p ?o ?g. }
Showing items 1 to 66 of
66
with 100 items per page.
- W3166783986 endingPage "42" @default.
- W3166783986 startingPage "34" @default.
- W3166783986 abstract "Treatment of distal humerus fractures is a complex problem in traumatology. The result of treatment depends on the choice of fixator according to the fracture area. Objective. To improve the technology of treatment in patients with complicated distal humerus fractures with fixators of small contact and multiplanar osteosynthesis and to evaluate its efficacy. Methods. 39 patients were treated for the period 2000–2020 with distal humerus nonunion (types 12-B1, 12-C1, 12-C2) and 23 patients with complicated above- and transcondylar humerus fractures (types 13-A2, 13-C1, 13-C2). Fixation of bone fragments of the distal humerus was made with device for fixation (Patent 17502 UA). It is a shaped plate with a groove on which half rings with threaded holes are stabilized. For the osteosynthesis of above- and transcondylar humerus fractures we used V-shaped plate with the possibility to regulate branch spreading width as for the condylar size (Patent 33358 UA). Autografting was performed as for necessity. Results. Plate osteosynthesis was performed mainly through anterior approach with minimal tissues traumatization. Release of radial nerve we made as for necessity. This device provides the stable fixation even in a case of short distal fragment. Device for bone fragments fixation was placed on the posterior condylar surface and lower part of the humerus through olecranon osteotomy. Osteosynthesis with suggested device is one of the options with bone autografting and can be method of choice at repeated surgery. Follow-up period was 1–2 years and later. In 60 patients we obtained good results with completed bone union. Conclusions. Suggested device can be used in cases of distal humerus nonunion. It allows to decrease the damage of surgery, to avoid many complications. Key words. Complicated fractures of the distal humerus, devices for limited-contact multiplanar osteosynthesis." @default.
- W3166783986 created "2021-06-22" @default.
- W3166783986 creator A5028677705 @default.
- W3166783986 date "2021-10-05" @default.
- W3166783986 modified "2023-09-25" @default.
- W3166783986 title "Treatment of patients with complicated fractures of the distal humerus using the fixators of limited-contact multiplanar osteosynthesis" @default.
- W3166783986 cites W1975507962 @default.
- W3166783986 cites W2024113073 @default.
- W3166783986 cites W2051429753 @default.
- W3166783986 cites W2321054629 @default.
- W3166783986 cites W2809551233 @default.
- W3166783986 cites W2965771843 @default.
- W3166783986 doi "https://doi.org/10.15674/0030-59872021134-42" @default.
- W3166783986 hasPublicationYear "2021" @default.
- W3166783986 type Work @default.
- W3166783986 sameAs 3166783986 @default.
- W3166783986 citedByCount "0" @default.
- W3166783986 crossrefType "journal-article" @default.
- W3166783986 hasAuthorship W3166783986A5028677705 @default.
- W3166783986 hasBestOaLocation W31667839861 @default.
- W3166783986 hasConcept C141071460 @default.
- W3166783986 hasConcept C146249460 @default.
- W3166783986 hasConcept C2776206872 @default.
- W3166783986 hasConcept C2776389721 @default.
- W3166783986 hasConcept C2777304102 @default.
- W3166783986 hasConcept C2779330695 @default.
- W3166783986 hasConcept C2780711802 @default.
- W3166783986 hasConcept C2781184374 @default.
- W3166783986 hasConcept C2908647359 @default.
- W3166783986 hasConcept C29694066 @default.
- W3166783986 hasConcept C71924100 @default.
- W3166783986 hasConcept C96646087 @default.
- W3166783986 hasConcept C99454951 @default.
- W3166783986 hasConceptScore W3166783986C141071460 @default.
- W3166783986 hasConceptScore W3166783986C146249460 @default.
- W3166783986 hasConceptScore W3166783986C2776206872 @default.
- W3166783986 hasConceptScore W3166783986C2776389721 @default.
- W3166783986 hasConceptScore W3166783986C2777304102 @default.
- W3166783986 hasConceptScore W3166783986C2779330695 @default.
- W3166783986 hasConceptScore W3166783986C2780711802 @default.
- W3166783986 hasConceptScore W3166783986C2781184374 @default.
- W3166783986 hasConceptScore W3166783986C2908647359 @default.
- W3166783986 hasConceptScore W3166783986C29694066 @default.
- W3166783986 hasConceptScore W3166783986C71924100 @default.
- W3166783986 hasConceptScore W3166783986C96646087 @default.
- W3166783986 hasConceptScore W3166783986C99454951 @default.
- W3166783986 hasIssue "1" @default.
- W3166783986 hasLocation W31667839861 @default.
- W3166783986 hasOpenAccess W3166783986 @default.
- W3166783986 hasPrimaryLocation W31667839861 @default.
- W3166783986 hasRelatedWork W1819661572 @default.
- W3166783986 hasRelatedWork W1965777090 @default.
- W3166783986 hasRelatedWork W2390036160 @default.
- W3166783986 hasRelatedWork W2783544372 @default.
- W3166783986 hasRelatedWork W2995043995 @default.
- W3166783986 hasRelatedWork W3024471208 @default.
- W3166783986 hasRelatedWork W3028773821 @default.
- W3166783986 hasRelatedWork W3166783986 @default.
- W3166783986 hasRelatedWork W3214635738 @default.
- W3166783986 hasRelatedWork W4317528624 @default.
- W3166783986 isParatext "false" @default.
- W3166783986 isRetracted "false" @default.
- W3166783986 magId "3166783986" @default.
- W3166783986 workType "article" @default.