Matches in SemOpenAlex for { <https://semopenalex.org/work/W3194534319> ?p ?o ?g. }
Showing items 1 to 65 of
65
with 100 items per page.
- W3194534319 endingPage "75" @default.
- W3194534319 startingPage "67" @default.
- W3194534319 abstract "The use of nonconventional power supplies featuring unstable quality of the electricity produced and fluctuations in the output power, on the one hand, and the availability of various consumers connected to power supply grids, on the other hand, are factors that give rise to phase unbalances in the grids. These circumstances complicate the operation of smart grids, especially in microgrids. One of possible ways to improve the quality of smart power supply grids is to use a three-stage solid-state transformer with galvanic isolation and two DC links, an arrangement that makes it possible to connect power supply sources and consumers, and to arrange backup storage of electricity in storage batteries. The aim of the study is to analyze the electric power quality at the output of a three-stage solid-state transformer powered by an unbalanced three-phase voltage source. The study was carried out by numerical modeling using the Matlab/Simulink software package. The modeling parameters are given, and the current and voltage waveforms at the solid-state transformer output are obtained. Phasors of the input and output voltages are constructed with expanding them into zero-, positive-, and negative sequence harmonic components. The harmonic distortion coefficients for current and voltage in each phase, and the voltage unbalance coefficients for the zero and negative sequences at the solid-state transformer input and output are determined using the method of symmetric components. It has been shown that by using solid-state transformers it becomes possible to obtain noticeably better quality of electric energy and eliminate the unbalance to the levels stipulated by the relevant state standard. It is shown that solid-state transformers are a promising technology as part of smart power supply grids, which opens the possibility to control and adjust power supply parameters, improve the power supply quality, distribute power flows between the sources and consumers, and integrate DC and AC grids of various voltage and power levels." @default.
- W3194534319 created "2021-08-30" @default.
- W3194534319 creator A5074271438 @default.
- W3194534319 date "2021-01-01" @default.
- W3194534319 modified "2023-09-24" @default.
- W3194534319 title "Eliminating Three-Phase Voltage Unbalance by Using a Solid-State Transformer in Smart Power Supply Grids" @default.
- W3194534319 doi "https://doi.org/10.24160/1993-6982-2021-4-67-75" @default.
- W3194534319 hasPublicationYear "2021" @default.
- W3194534319 type Work @default.
- W3194534319 sameAs 3194534319 @default.
- W3194534319 citedByCount "1" @default.
- W3194534319 countsByYear W31945343192022 @default.
- W3194534319 crossrefType "journal-article" @default.
- W3194534319 hasAuthorship W3194534319A5074271438 @default.
- W3194534319 hasConcept C10558101 @default.
- W3194534319 hasConcept C117323899 @default.
- W3194534319 hasConcept C119599485 @default.
- W3194534319 hasConcept C121332964 @default.
- W3194534319 hasConcept C127413603 @default.
- W3194534319 hasConcept C151799858 @default.
- W3194534319 hasConcept C163258240 @default.
- W3194534319 hasConcept C165801399 @default.
- W3194534319 hasConcept C24326235 @default.
- W3194534319 hasConcept C41008148 @default.
- W3194534319 hasConcept C42156128 @default.
- W3194534319 hasConcept C50825304 @default.
- W3194534319 hasConcept C62520636 @default.
- W3194534319 hasConcept C64424096 @default.
- W3194534319 hasConcept C66322947 @default.
- W3194534319 hasConcept C89227174 @default.
- W3194534319 hasConceptScore W3194534319C10558101 @default.
- W3194534319 hasConceptScore W3194534319C117323899 @default.
- W3194534319 hasConceptScore W3194534319C119599485 @default.
- W3194534319 hasConceptScore W3194534319C121332964 @default.
- W3194534319 hasConceptScore W3194534319C127413603 @default.
- W3194534319 hasConceptScore W3194534319C151799858 @default.
- W3194534319 hasConceptScore W3194534319C163258240 @default.
- W3194534319 hasConceptScore W3194534319C165801399 @default.
- W3194534319 hasConceptScore W3194534319C24326235 @default.
- W3194534319 hasConceptScore W3194534319C41008148 @default.
- W3194534319 hasConceptScore W3194534319C42156128 @default.
- W3194534319 hasConceptScore W3194534319C50825304 @default.
- W3194534319 hasConceptScore W3194534319C62520636 @default.
- W3194534319 hasConceptScore W3194534319C64424096 @default.
- W3194534319 hasConceptScore W3194534319C66322947 @default.
- W3194534319 hasConceptScore W3194534319C89227174 @default.
- W3194534319 hasLocation W31945343191 @default.
- W3194534319 hasOpenAccess W3194534319 @default.
- W3194534319 hasPrimaryLocation W31945343191 @default.
- W3194534319 hasRelatedWork W1827185341 @default.
- W3194534319 hasRelatedWork W2010418084 @default.
- W3194534319 hasRelatedWork W2094495059 @default.
- W3194534319 hasRelatedWork W2131696955 @default.
- W3194534319 hasRelatedWork W2348107051 @default.
- W3194534319 hasRelatedWork W2350175534 @default.
- W3194534319 hasRelatedWork W2354065378 @default.
- W3194534319 hasRelatedWork W2366681273 @default.
- W3194534319 hasRelatedWork W2373443317 @default.
- W3194534319 hasRelatedWork W3022232835 @default.
- W3194534319 isParatext "false" @default.
- W3194534319 isRetracted "false" @default.
- W3194534319 magId "3194534319" @default.
- W3194534319 workType "article" @default.