- W3208193437 abstract "Central MessageRDAVR has been associated with increased rates of PPM compared to conventional AVR. Appropriate matching and careful attention to bioprosthesis-specific technical details may reduce this complication.See Article page 219. RDAVR has been associated with increased rates of PPM compared to conventional AVR. Appropriate matching and careful attention to bioprosthesis-specific technical details may reduce this complication. See Article page 219. The goal of heart valve centers in the treatment of valvular heart disease is to deliver optimal quality of care with a patient-centered approach.1Vahanian A. Beyersdorf F. Praz F. Milojevic M. Baldus S. Bauersachs J. et al.2021 ESC/EACTS guidelines for the management of valvular heart disease.Eur J Cardiothorac Surg. 2021; 60: 727-800Crossref PubMed Scopus (73) Google Scholar In terms of a patient-centered approach, rapid deployment and sutureless aortic valve replacement (AVR) have become a focus of interest in the surgical community in the last 2 decades. Excellent safety profiles, ease of implantation, reduced procedural time, hemodynamic performance, and reproducibility made these valves excellent alternatives to both traditional aortic prosthesis and transcatheter aortic valves. However, increased postoperative conduction disturbances and the need for permanent pacemaker (PPM) implantation are significant concerns for transcatheter, sutureless, and rapid-deployment technologies.2Coti I. Schukro C. Drevinja F. Haberl T. Kaider A. Kocher A. et al.Conduction disturbances following surgical aortic valve replacement with a rapid-deployment bioprosthesis.J Thorac Cardiovasc Surg. 2021; 162: 803-811Abstract Full Text Full Text PDF PubMed Scopus (11) Google Scholar, 3Moscarelli M. Santarpino G. Athanasiou T. Mastroroberto P. Fattouch K. Nasso G. et al.A pooled analysis of pacemaker implantation after Perceval sutureless aortic valve replacement.Interact Cardiovasc Thorac Surg. 2021; 33: 501-509Crossref PubMed Scopus (1) Google Scholar, 4Muneretto C. Solinas M. Folliguet T. Di Bartolomeo R. Repossini A. Laborde F. et al.Sutureless versus transcatheter aortic valves in elderly patients with aortic stenosis at intermediate risk: a multi-institutional study.J Thorac Cardiovasc Surg. June 15, 2020; ([Epub ahead of print])Abstract Full Text Full Text PDF PubMed Scopus (8) Google Scholar Thuraisingam and Newcomb5Thuraisingam A. Newcomb A.E. Rhythm disturbances following rapid-deployment aortic valve replacement.J Thorac Cardiovasc Surg Tech. 2021; 10: 219-226Scopus (2) Google Scholar performed a case series of 100 consecutive patients who underwent rapid-deployment AVR with Edwards Intuity Elite valve at St Vincent's Hospital Melbourne from 2013 to 2017. They aimed to examine electrocardiogram (ECG) changes, conduction abnormalities, and rates of pacemaker implantation in this cohort. Three patients were excluded from the study for the preoperative pacemaker requirement, leaving 97 patients for final analysis. The authors analyzed 12-lead ECGs at 3 time points: preoperative, 5 days' postoperative, and follow-up at 6 weeks. A total of 14 patients (14.4%) had a PPM implanted at an average of 11.1 ± 2.9 days postoperatively. The authors analyzed heart rate, PR, QRS, and cQT conduction intervals for recipients of PPM (n = 14) compared with nonrecipients (n = 83). A new-onset (18.6%) but transient left bundle branch block (LBBB) at postoperative day 5 was detected. However, only 4.1% of patients had persistent LBBB at 6-week follow-up. The authors concluded that widened QRS complex might predispose to PPM requirement in the rapid-deployment AVR setting, and new-onset LBBB may resolve over time. The results are consistent with the recently published series.2Coti I. Schukro C. Drevinja F. Haberl T. Kaider A. Kocher A. et al.Conduction disturbances following surgical aortic valve replacement with a rapid-deployment bioprosthesis.J Thorac Cardiovasc Surg. 2021; 162: 803-811Abstract Full Text Full Text PDF PubMed Scopus (11) Google Scholar Changing characteristics of conduction disorders over time is clinically relevant. Potential causes include excessive oversizing, intra-annular placement, expandable property with radial force, inflammation, edema, ischemia of the surrounding tissue, subannular skirt of the prosthesis within the left ventricular outflow tract, and compression to the conduction system should all be taken into account in terms of surgical technique. Overall strengths of the article are precise aim, justified research question, relevant results, impressive series of this new procedure, well-described surgical technique, and the literature review. Overall weaknesses of the article, as mentioned in the limitations, are retrospective single-center study design, 3-time point ECG methodology, limited follow-up of 6 weeks, and concomitant procedures, which may affect the rhythm status. In brief, the case series5Thuraisingam A. Newcomb A.E. Rhythm disturbances following rapid-deployment aortic valve replacement.J Thorac Cardiovasc Surg Tech. 2021; 10: 219-226Scopus (2) Google Scholar encourages the use of rapid-deployment and sutureless aortic bioprostheses with careful case selection. The authors must be congratulated for challenging research question, data processing, and efforts to prevent PPM. A large-scale randomized comparison is still warranted. Rhythm disturbances following rapid-deployment aortic valve replacementJTCVS TechniquesVol. 10PreviewThere have been reports of postoperative conduction disturbances after rapid-deployment aortic valve replacement. Our objective was to assess electrocardiogram changes in patients undergoing this procedure and review the literature on this topic. Full-Text PDF Open Access" @default.
- W3208193437 created "2021-11-08" @default.
- W3208193437 creator A5018753900 @default.
- W3208193437 creator A5024236877 @default.
- W3208193437 date "2021-10-01" @default.
- W3208193437 modified "2023-09-27" @default.
- W3208193437 title "Commentary: Similar Rhythm Disturbance Profiles of Rapid-deployment Aortic Valve Bioprostheses" @default.
- W3208193437 cites W3007792673 @default.
- W3208193437 cites W3035373205 @default.
- W3208193437 cites W3160845309 @default.
- W3208193437 cites W3193942184 @default.
- W3208193437 doi "https://doi.org/10.1016/j.xjtc.2021.10.044" @default.
- W3208193437 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/34984382" @default.
- W3208193437 hasPublicationYear "2021" @default.
- W3208193437 type Work @default.
- W3208193437 sameAs 3208193437 @default.
- W3208193437 citedByCount "0" @default.
- W3208193437 crossrefType "journal-article" @default.
- W3208193437 hasAuthorship W3208193437A5018753900 @default.
- W3208193437 hasAuthorship W3208193437A5024236877 @default.
- W3208193437 hasBestOaLocation W32081934371 @default.
- W3208193437 hasConcept C105339364 @default.
- W3208193437 hasConcept C111919701 @default.
- W3208193437 hasConcept C126322002 @default.
- W3208193437 hasConcept C141071460 @default.
- W3208193437 hasConcept C164705383 @default.
- W3208193437 hasConcept C2776570981 @default.
- W3208193437 hasConcept C2779736815 @default.
- W3208193437 hasConcept C2780007028 @default.
- W3208193437 hasConcept C41008148 @default.
- W3208193437 hasConcept C71924100 @default.
- W3208193437 hasConceptScore W3208193437C105339364 @default.
- W3208193437 hasConceptScore W3208193437C111919701 @default.
- W3208193437 hasConceptScore W3208193437C126322002 @default.
- W3208193437 hasConceptScore W3208193437C141071460 @default.
- W3208193437 hasConceptScore W3208193437C164705383 @default.
- W3208193437 hasConceptScore W3208193437C2776570981 @default.
- W3208193437 hasConceptScore W3208193437C2779736815 @default.
- W3208193437 hasConceptScore W3208193437C2780007028 @default.
- W3208193437 hasConceptScore W3208193437C41008148 @default.
- W3208193437 hasConceptScore W3208193437C71924100 @default.
- W3208193437 hasLocation W32081934371 @default.
- W3208193437 hasLocation W32081934372 @default.
- W3208193437 hasLocation W32081934373 @default.
- W3208193437 hasOpenAccess W3208193437 @default.
- W3208193437 hasPrimaryLocation W32081934371 @default.
- W3208193437 hasRelatedWork W102044625 @default.
- W3208193437 hasRelatedWork W2056763771 @default.
- W3208193437 hasRelatedWork W2069282589 @default.
- W3208193437 hasRelatedWork W2074833529 @default.
- W3208193437 hasRelatedWork W2354457233 @default.
- W3208193437 hasRelatedWork W2389436658 @default.
- W3208193437 hasRelatedWork W2414320482 @default.
- W3208193437 hasRelatedWork W2471596985 @default.
- W3208193437 hasRelatedWork W2920644863 @default.
- W3208193437 hasRelatedWork W3126586449 @default.
- W3208193437 isParatext "false" @default.
- W3208193437 isRetracted "false" @default.
- W3208193437 magId "3208193437" @default.
- W3208193437 workType "article" @default.