Matches in SemOpenAlex for { <https://semopenalex.org/work/W4200515786> ?p ?o ?g. }
Showing items 1 to 75 of
75
with 100 items per page.
- W4200515786 endingPage "022050" @default.
- W4200515786 startingPage "022050" @default.
- W4200515786 abstract "Abstract The results of tests for drawing anchor fibers with a length of 50 mm and a diameter of 1 mm, laid at the end of concrete prisms 50x50x100 mm made of fine-grained concrete of classes C 20/25, C25/30 and C 30/35 are presented. From the tests of 50 fibers, the average value of tensile strength was determined, which is equal to 1242 MPa with a coefficient of variation of 2.1%. Prisms were made of fine-grained concrete, which included cement with an activity of 41.2 MPa for concrete class C 20/25 and an activity of 50.8 MPa for concrete classes C 25/30 and C 30/35. Sand with a modulus of size 2.1 was used as a filler. The concrete mixture was prepared in a forced concrete mixer, and the concrete was compacted on a vibrating platform. Simultaneously with these prisms, cubes with dimensions of 150x150x150 mm and prisms with dimensions of 100x100x400 mm were made to determine the bottom and prism strength of concrete. The length of laying fibers into concrete was 10,15 and 25 mm. It is shown that the forces perceived by the end anchors and the smooth part of the fibers rise with increasing strength of concrete. The results of tests for drawing fibers from concrete prisms are given in tables 1 - 3. For the length of laying fiber 10 mm into prisms with strength f cm,cube = 29.31 MPa and f cm,prism = 23.15 MPa the maximum stresses during drawing were 515.30 - 549.04 MPa (average value - 532.10 MPa). At the same length of laying fiber into concrete prisms with strength f cm,cube = 34.76 MPa and f cm,prism = 27.11 MPa , these stresses were equal to 554.47 - 588.54 MPa (average value - 569.70 MPa). For the length of laying the fiber 10 mm into prisms with strength f cm,cube = 38.96 MPa and f cm,prism = 31.14 MPa, the maximum tensile stresses were 590.51 - 621.72 MPa (average value - 606.81MPa). At the specified strengths of the prism concrete, the maximum values of the average stresses for fiber drawing were on average 13.37 MPa for concrete of class C20/25, 14.34 MPa for concrete of class C25/30 and 15.27 MPa for concrete of class C30/35. With a fiber laying length of 15 mm into prisms with concrete strength corresponding to class C20/25, the maximum tensile stresses were 575.80 - 607.64 MPa (average value - 587.10 MPa). With such a length of laying fiber into prisms made of concrete class C25/30, these stresses were equal to 614.44 - 680.25 MPa (average value - 638.95 MPa). At the length of laying the fiber 15 mm into the prisms of concrete class C30/35, the maximum stresses during drawing were 681.14 - 692.99 MPa (average value - 685.44 MPa). The maximum values of average stresses for fiber drawing were on average 9.87 MPa for concrete of class C20/25, 10.70 MPa for concrete of class C25/30 and 11.52 MPa for concrete of class C30/35. At a fiber laying length of 25 mm into prisms with concrete strength corresponding to class C20/25, the maximum tensile stresses were 645.44 - 735.03 MPa (average value - 692.76 MPa). With such a length of laying fiber into prisms made of concrete class C25/30, these stresses were equal to 736.58 - 773.25 MPa (average value - 752.37 MPa). With the length of laying fiber 25 mm into prisms made of concrete class C30/35, maximum stresses during drawing were equal to 780.27 - 839.49 MPa (average value - 809.12 MPa). The maximum values of the average stresses during fiber drawing were on average 6.97 MPa for concrete of class C20/25, 7.57 MPa for concrete of class C25/30 and 8.12 MPa for concrete of class C30/35. The coefficient of anchoring capacity η, which under Ukrainian standards of fibroconcrete structures designing is equal to 0.9, as shown by the data of our experiments, is not constant, so it is necessary to take this into account in the formula for determining the tensile strength of fibroconcrete." @default.
- W4200515786 created "2021-12-31" @default.
- W4200515786 creator A5008088859 @default.
- W4200515786 creator A5008811444 @default.
- W4200515786 creator A5050669030 @default.
- W4200515786 creator A5077238812 @default.
- W4200515786 date "2021-11-01" @default.
- W4200515786 modified "2023-09-30" @default.
- W4200515786 title "Gripping of Anchor Fiber of Ukrainian Production with Fine- Grain Concrete" @default.
- W4200515786 cites W1990099419 @default.
- W4200515786 cites W2003313317 @default.
- W4200515786 cites W2004924645 @default.
- W4200515786 cites W2602953967 @default.
- W4200515786 cites W2907170316 @default.
- W4200515786 cites W2918021057 @default.
- W4200515786 cites W2973998587 @default.
- W4200515786 cites W3038721603 @default.
- W4200515786 cites W3113235372 @default.
- W4200515786 doi "https://doi.org/10.1088/1757-899x/1203/2/022050" @default.
- W4200515786 hasPublicationYear "2021" @default.
- W4200515786 type Work @default.
- W4200515786 citedByCount "1" @default.
- W4200515786 countsByYear W42005157862022 @default.
- W4200515786 crossrefType "journal-article" @default.
- W4200515786 hasAuthorship W4200515786A5008088859 @default.
- W4200515786 hasAuthorship W4200515786A5008811444 @default.
- W4200515786 hasAuthorship W4200515786A5050669030 @default.
- W4200515786 hasAuthorship W4200515786A5077238812 @default.
- W4200515786 hasBestOaLocation W42005157861 @default.
- W4200515786 hasConcept C112950240 @default.
- W4200515786 hasConcept C120665830 @default.
- W4200515786 hasConcept C121332964 @default.
- W4200515786 hasConcept C159985019 @default.
- W4200515786 hasConcept C192562407 @default.
- W4200515786 hasConcept C193867417 @default.
- W4200515786 hasConcept C2524010 @default.
- W4200515786 hasConcept C30407753 @default.
- W4200515786 hasConcept C33923547 @default.
- W4200515786 hasConcept C519885992 @default.
- W4200515786 hasConcept C523993062 @default.
- W4200515786 hasConcept C53051483 @default.
- W4200515786 hasConcept C67666897 @default.
- W4200515786 hasConceptScore W4200515786C112950240 @default.
- W4200515786 hasConceptScore W4200515786C120665830 @default.
- W4200515786 hasConceptScore W4200515786C121332964 @default.
- W4200515786 hasConceptScore W4200515786C159985019 @default.
- W4200515786 hasConceptScore W4200515786C192562407 @default.
- W4200515786 hasConceptScore W4200515786C193867417 @default.
- W4200515786 hasConceptScore W4200515786C2524010 @default.
- W4200515786 hasConceptScore W4200515786C30407753 @default.
- W4200515786 hasConceptScore W4200515786C33923547 @default.
- W4200515786 hasConceptScore W4200515786C519885992 @default.
- W4200515786 hasConceptScore W4200515786C523993062 @default.
- W4200515786 hasConceptScore W4200515786C53051483 @default.
- W4200515786 hasConceptScore W4200515786C67666897 @default.
- W4200515786 hasIssue "2" @default.
- W4200515786 hasLocation W42005157861 @default.
- W4200515786 hasOpenAccess W4200515786 @default.
- W4200515786 hasPrimaryLocation W42005157861 @default.
- W4200515786 hasRelatedWork W2089085266 @default.
- W4200515786 hasRelatedWork W2140455416 @default.
- W4200515786 hasRelatedWork W2384810906 @default.
- W4200515786 hasRelatedWork W2729932191 @default.
- W4200515786 hasRelatedWork W2795554382 @default.
- W4200515786 hasRelatedWork W2811120771 @default.
- W4200515786 hasRelatedWork W2899531431 @default.
- W4200515786 hasRelatedWork W2944045227 @default.
- W4200515786 hasRelatedWork W3122552578 @default.
- W4200515786 hasRelatedWork W4250148979 @default.
- W4200515786 hasVolume "1203" @default.
- W4200515786 isParatext "false" @default.
- W4200515786 isRetracted "false" @default.
- W4200515786 workType "article" @default.