Matches in SemOpenAlex for { <https://semopenalex.org/work/W4284883132> ?p ?o ?g. }
- W4284883132 endingPage "119589" @default.
- W4284883132 startingPage "119589" @default.
- W4284883132 abstract "Nowadays, the proportion of thermal power generation is still large, the waste of electricity will lead to more environmental pollution. With the continuous increase in electricity demand, how to improve the quality of power supply, reduce transmission loss and ease the burden of power grid are urgent problems to be solved. The combination of fuel cell and energy storage technology could be a good solution. In this article, a new off-grid system with peak load shifting function is proposed to solve problems of power supply in remote regions. This combined system consists of a solid oxide fuel cell, a regenerative Brayton cycle, an organic Rankine cycle and a compressed-air energy storage system. By rational utilization of waste heat in exhaust gas, the cascade utilization of energy can be realized. The results indicate that the fuel cell-waste heat recovery system can achieve higher thermal efficiency and exergy efficiency, with an improvement of 6.69% and 6.46%, respectively. The application of compressed-air energy storage system not only makes the system have the functions of energy storage and peak regulation, but also improves the economic performance. The system reaches a minimum payback time of 4 years in the case presented. In conclusion, this new combined system is clean, efficient and economical, which can provide a good solution for power supply in coteaux, suburbs and islands." @default.
- W4284883132 created "2022-07-09" @default.
- W4284883132 creator A5019968053 @default.
- W4284883132 creator A5026144933 @default.
- W4284883132 creator A5044513573 @default.
- W4284883132 creator A5046477557 @default.
- W4284883132 creator A5082052963 @default.
- W4284883132 date "2022-10-01" @default.
- W4284883132 modified "2023-09-30" @default.
- W4284883132 title "A micro off-grid power solution for solid oxide fuel cell waste heat reusing enabled peak load shifting by integrating compressed-air energy storage" @default.
- W4284883132 cites W1974512306 @default.
- W4284883132 cites W1988161187 @default.
- W4284883132 cites W1997659661 @default.
- W4284883132 cites W2010363300 @default.
- W4284883132 cites W2010922597 @default.
- W4284883132 cites W2053575229 @default.
- W4284883132 cites W2086206798 @default.
- W4284883132 cites W2176757999 @default.
- W4284883132 cites W2302833178 @default.
- W4284883132 cites W2492545696 @default.
- W4284883132 cites W2507522375 @default.
- W4284883132 cites W2514066473 @default.
- W4284883132 cites W2767765183 @default.
- W4284883132 cites W2789337162 @default.
- W4284883132 cites W2807528954 @default.
- W4284883132 cites W2807870197 @default.
- W4284883132 cites W2884968426 @default.
- W4284883132 cites W2885719640 @default.
- W4284883132 cites W2911011298 @default.
- W4284883132 cites W2911399034 @default.
- W4284883132 cites W2913855861 @default.
- W4284883132 cites W2922703668 @default.
- W4284883132 cites W2938197184 @default.
- W4284883132 cites W2949864138 @default.
- W4284883132 cites W2950191137 @default.
- W4284883132 cites W2953910299 @default.
- W4284883132 cites W2965685479 @default.
- W4284883132 cites W2973788341 @default.
- W4284883132 cites W2984043448 @default.
- W4284883132 cites W2991790462 @default.
- W4284883132 cites W2997615046 @default.
- W4284883132 cites W3000250404 @default.
- W4284883132 cites W3002062275 @default.
- W4284883132 cites W3004029206 @default.
- W4284883132 cites W3004754538 @default.
- W4284883132 cites W3009798587 @default.
- W4284883132 cites W3036775699 @default.
- W4284883132 cites W3078533173 @default.
- W4284883132 cites W3085774225 @default.
- W4284883132 cites W3086825708 @default.
- W4284883132 cites W3104131193 @default.
- W4284883132 cites W3107175967 @default.
- W4284883132 cites W3110959049 @default.
- W4284883132 cites W3113668960 @default.
- W4284883132 cites W3120927007 @default.
- W4284883132 cites W3130544315 @default.
- W4284883132 cites W3140642350 @default.
- W4284883132 cites W3176101745 @default.
- W4284883132 cites W3176630539 @default.
- W4284883132 cites W3178516345 @default.
- W4284883132 cites W3192252397 @default.
- W4284883132 cites W3194518010 @default.
- W4284883132 cites W4200331660 @default.
- W4284883132 cites W4206544829 @default.
- W4284883132 cites W4234875371 @default.
- W4284883132 cites W4248077106 @default.
- W4284883132 cites W3208519917 @default.
- W4284883132 doi "https://doi.org/10.1016/j.apenergy.2022.119589" @default.
- W4284883132 hasPublicationYear "2022" @default.
- W4284883132 type Work @default.
- W4284883132 citedByCount "7" @default.
- W4284883132 countsByYear W42848831322023 @default.
- W4284883132 crossrefType "journal-article" @default.
- W4284883132 hasAuthorship W4284883132A5019968053 @default.
- W4284883132 hasAuthorship W4284883132A5026144933 @default.
- W4284883132 hasAuthorship W4284883132A5044513573 @default.
- W4284883132 hasAuthorship W4284883132A5046477557 @default.
- W4284883132 hasAuthorship W4284883132A5082052963 @default.
- W4284883132 hasConcept C107706546 @default.
- W4284883132 hasConcept C119599485 @default.
- W4284883132 hasConcept C121332964 @default.
- W4284883132 hasConcept C127413603 @default.
- W4284883132 hasConcept C147789679 @default.
- W4284883132 hasConcept C163258240 @default.
- W4284883132 hasConcept C171146098 @default.
- W4284883132 hasConcept C17525397 @default.
- W4284883132 hasConcept C183287310 @default.
- W4284883132 hasConcept C184235594 @default.
- W4284883132 hasConcept C185592680 @default.
- W4284883132 hasConcept C188573790 @default.
- W4284883132 hasConcept C18903297 @default.
- W4284883132 hasConcept C21880701 @default.
- W4284883132 hasConcept C2778449969 @default.
- W4284883132 hasConcept C2778456004 @default.
- W4284883132 hasConcept C2780113879 @default.
- W4284883132 hasConcept C39432304 @default.
- W4284883132 hasConcept C42611778 @default.
- W4284883132 hasConcept C544738498 @default.