Matches in SemOpenAlex for { <https://semopenalex.org/work/W4313291315> ?p ?o ?g. }
Showing items 1 to 61 of
61
with 100 items per page.
- W4313291315 endingPage "42" @default.
- W4313291315 startingPage "30" @default.
- W4313291315 abstract "Introduction. The analysis of existing methods for determining the estimated time of fire detection by means of fire automatics allows us to conclude that it is advisable to use a more differentiated approach. Within the framework of this article, the assumption about the influence of the distance from the burning plane of the fire seat to the level of installation of fire detectors (to the sensitive elements of point smoke fire detectors) on the estimated time of fire detection was carried out. In particular, such an effect can be observed during a fire involving the burning of furniture, shelving, etc., i.e. in cases where the above distance is potentially shortened. Goals and objectives. The aim of the work is to study the influence of the distance from the burning plane of the fire seat to the level of installation of fire detectors (to the sensitive elements of point smoke detectors) on the estimated time of fire detection. Research methods. To assess the influence of the distance from the burning plane of the fire seat to the level of installation of fire detectors (to the sensitive elements of point smoke fire detectors) on the estimated time of fire detection, computer simulation methods were used using the Fire Dynamics Simulator software package. Results and its discussion. The results of modeling the dynamics of the optical density of smoke in a room at various distances from the burning plane of the fire seat to the level of installation of fire detectors (to the sensitive elements of point smoke fire detectors) are presented. The distance varied in the range from 0.25 to 2.75 m. Conclusions. It has been established that the distance from the burning plane of the fire source to the level of installation of fire detectors (to the sensitive elements of point smoke detectors) does not have a significant effect on the estimated time of fire detection. The difference in the values of the estimated fire detection time for different values of the distance from the burning plane of the fire source to the level of installation of fire detectors and the value obtained on the basis of the existing method for determining the time of the start of evacuation may indicate an unreliable assessment of the total time of the start of evacuation and incorrect conclusions about safe evacuation people and/or the likelihood of people evacuating. To correctly take into account the time of the beginning of the evacuation, further study of this issue and comparison of its technical component, obtained by calculation methods, with the results of field experiments is required. Keywords: fire safety, fire protection, fire detection time, fire alarm, evacuation probability, smoke optical density, evacuation time, evacuation start time, fire risk." @default.
- W4313291315 created "2023-01-06" @default.
- W4313291315 creator A5005700357 @default.
- W4313291315 creator A5087874573 @default.
- W4313291315 date "2022-01-01" @default.
- W4313291315 modified "2023-09-27" @default.
- W4313291315 title "Influence of the distance from the burning plane of a fire seat to the level of installation of fire detectors on the estimated fire detection time" @default.
- W4313291315 doi "https://doi.org/10.25257/tts.2022.4.98.30-42" @default.
- W4313291315 hasPublicationYear "2022" @default.
- W4313291315 type Work @default.
- W4313291315 citedByCount "0" @default.
- W4313291315 crossrefType "journal-article" @default.
- W4313291315 hasAuthorship W4313291315A5005700357 @default.
- W4313291315 hasAuthorship W4313291315A5087874573 @default.
- W4313291315 hasConcept C119599485 @default.
- W4313291315 hasConcept C127413603 @default.
- W4313291315 hasConcept C170154142 @default.
- W4313291315 hasConcept C17825722 @default.
- W4313291315 hasConcept C2524010 @default.
- W4313291315 hasConcept C2777218256 @default.
- W4313291315 hasConcept C2780836893 @default.
- W4313291315 hasConcept C28719098 @default.
- W4313291315 hasConcept C33923547 @default.
- W4313291315 hasConcept C39432304 @default.
- W4313291315 hasConcept C44154836 @default.
- W4313291315 hasConcept C548081761 @default.
- W4313291315 hasConcept C58874564 @default.
- W4313291315 hasConcept C94915269 @default.
- W4313291315 hasConceptScore W4313291315C119599485 @default.
- W4313291315 hasConceptScore W4313291315C127413603 @default.
- W4313291315 hasConceptScore W4313291315C170154142 @default.
- W4313291315 hasConceptScore W4313291315C17825722 @default.
- W4313291315 hasConceptScore W4313291315C2524010 @default.
- W4313291315 hasConceptScore W4313291315C2777218256 @default.
- W4313291315 hasConceptScore W4313291315C2780836893 @default.
- W4313291315 hasConceptScore W4313291315C28719098 @default.
- W4313291315 hasConceptScore W4313291315C33923547 @default.
- W4313291315 hasConceptScore W4313291315C39432304 @default.
- W4313291315 hasConceptScore W4313291315C44154836 @default.
- W4313291315 hasConceptScore W4313291315C548081761 @default.
- W4313291315 hasConceptScore W4313291315C58874564 @default.
- W4313291315 hasConceptScore W4313291315C94915269 @default.
- W4313291315 hasLocation W43132913151 @default.
- W4313291315 hasOpenAccess W4313291315 @default.
- W4313291315 hasPrimaryLocation W43132913151 @default.
- W4313291315 hasRelatedWork W2001836338 @default.
- W4313291315 hasRelatedWork W2053673823 @default.
- W4313291315 hasRelatedWork W2083231941 @default.
- W4313291315 hasRelatedWork W2093040160 @default.
- W4313291315 hasRelatedWork W2128134392 @default.
- W4313291315 hasRelatedWork W2151399616 @default.
- W4313291315 hasRelatedWork W2326364741 @default.
- W4313291315 hasRelatedWork W2367659265 @default.
- W4313291315 hasRelatedWork W2482362140 @default.
- W4313291315 hasRelatedWork W919582838 @default.
- W4313291315 hasVolume "98" @default.
- W4313291315 isParatext "false" @default.
- W4313291315 isRetracted "false" @default.
- W4313291315 workType "article" @default.