Matches in SemOpenAlex for { <https://semopenalex.org/work/W4313488052> ?p ?o ?g. }
Showing items 1 to 72 of
72
with 100 items per page.
- W4313488052 endingPage "405" @default.
- W4313488052 startingPage "395" @default.
- W4313488052 abstract "PURPOSE OF THE STUDY In the last number of years, the anatomic hemiarthoplasty has gradually been pushed out of clinical practice by modern reverse shoulder arthroplasty (RSA) designs. This is due to the clear excellent functional results of RSAs in a wide spectrum of indication criteria. Nevertheless, RSAs have several possible complications that cannot occur in an anatomic hemiarthroplasty. In anatomic hemiarthoplasty, the importance of correct indication criteria and observing correct operative technique including soft tissue reconstruction is much more important than in RSA. Furthermore, there is a clear recent trend of increased use of humeral components fixed only in the proximal metaphyseal cancellous bone. Our aim was to summarise our six-year experience with the SMR® Stemless (LimaCorporate, Italy) system which is one of the most modern ones. MATERIAL AND METHODS Twenty cases of SMR® Stemless anatomic shoulder hemiarthroplasty performed between 2016 and 2021 were included in the study. All patients were followed up prospectively. The function was evaluated preoperatively and at the last follow-up. We evaluated the range of active elevation, classic Constant Score (CS) and pain level according to the visual analogue scale (VAS). Statistical evaluation was performed by using basic statistical methods and the statistical significance of the results was assessed with a paired t-test. Level of statistical significance was set at p= 0.01. RESULTS The mean follow-up in our cohort was 3.01 years (range 0.32-5.69, Median 2.82, SD 1.56) All cases were indicated for surgery due to primary osteoarthritis with a limitation of movement and pain. The mean postoperative CS was 85.7 (range 70-96, Median 86, SD 6.83). The mean active elevation postoperatively was 143° (range 100-170°, Median 150°, SD 20.76). Mean postoperative pain according to VAS was 1.05 (range 0-4, Median 1, SD 1.02). The mean preoperative elevation was 60.5° (range 30-100°, Median 65°, SD 18.83). After surgery the mean elevation increased to 143° (range 100-170°, Median 150°, SD 20.76). Statistical evaluation showed a statistically significant increase in the CS (41.7 preoperatively to 85.7 postoperatively), range of active elevation (60.5° preoperatively to 143° postoperatively) and a statistically significant decrease in pain (VAS 6.95 preoperatively to 1.05 postoperatively). We observed no cases of failure or loosening of the implant. A statistically significant increase in post-operative range of motion was demonstrated. DISCUSSION Most modern shoulder arthroplasty designs now include implants allowing for proximal humerus metaphyseal fixation in hemiarthroplasty and even RSA designs. The advantage of metaphyseal fixation without the use of a longer stem is clear. Notably, treatment of periprosthetic humeral fractures is simpler, extraction of the implant for any reason is easier and the preoperative anatomic position of the humeral head can be respected. As with any anatomic shoulder arthroplasty, the functional result is dependent on correct indication criteria, precise surgical technique, correct humeral head position and soft tissue reconstruction - primarily the rotator cuff. CONCLUSIONS Between 2016 and 2021, we performed 20 SMR® stemless shoulder hemiarthroplasties for primary osteoarthritis. The mean follow up was 3 years. The shoulder function improved significantly post-operatively in all patients. There were no cases of implant loosening or failure. Radiographic evaluation showed no implant loosening or change in implant position in the humeral metaphysis. Key words: shoulder joint replacement, reverse shoulder arthroplasty, SMR, stemless, total shoulder arthroplasty, shoulder hemiarthroplasty, EPOCA, wear." @default.
- W4313488052 created "2023-01-06" @default.
- W4313488052 creator A5021174483 @default.
- W4313488052 creator A5027866184 @default.
- W4313488052 creator A5028712320 @default.
- W4313488052 creator A5045650236 @default.
- W4313488052 creator A5066188597 @default.
- W4313488052 creator A5089503985 @default.
- W4313488052 date "2022-12-15" @default.
- W4313488052 modified "2023-10-18" @default.
- W4313488052 title "Stemless Hemiarthroplasty of the Shoulder Using the SMR® System: Summary of Six-Year Experience and Surgical Technique" @default.
- W4313488052 cites W1841387130 @default.
- W4313488052 cites W1964565782 @default.
- W4313488052 cites W1967200076 @default.
- W4313488052 cites W2021677046 @default.
- W4313488052 cites W2037405274 @default.
- W4313488052 cites W2281200901 @default.
- W4313488052 cites W2318504856 @default.
- W4313488052 cites W2471780894 @default.
- W4313488052 cites W2885841963 @default.
- W4313488052 cites W3144508603 @default.
- W4313488052 cites W3197757870 @default.
- W4313488052 doi "https://doi.org/10.55095/achot2022/064" @default.
- W4313488052 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/36594686" @default.
- W4313488052 hasPublicationYear "2022" @default.
- W4313488052 type Work @default.
- W4313488052 citedByCount "0" @default.
- W4313488052 crossrefType "journal-article" @default.
- W4313488052 hasAuthorship W4313488052A5021174483 @default.
- W4313488052 hasAuthorship W4313488052A5027866184 @default.
- W4313488052 hasAuthorship W4313488052A5028712320 @default.
- W4313488052 hasAuthorship W4313488052A5045650236 @default.
- W4313488052 hasAuthorship W4313488052A5066188597 @default.
- W4313488052 hasAuthorship W4313488052A5089503985 @default.
- W4313488052 hasBestOaLocation W43134880521 @default.
- W4313488052 hasConcept C126322002 @default.
- W4313488052 hasConcept C136948725 @default.
- W4313488052 hasConcept C141071460 @default.
- W4313488052 hasConcept C2778336525 @default.
- W4313488052 hasConcept C63363279 @default.
- W4313488052 hasConcept C65409693 @default.
- W4313488052 hasConcept C71924100 @default.
- W4313488052 hasConcept C72563966 @default.
- W4313488052 hasConceptScore W4313488052C126322002 @default.
- W4313488052 hasConceptScore W4313488052C136948725 @default.
- W4313488052 hasConceptScore W4313488052C141071460 @default.
- W4313488052 hasConceptScore W4313488052C2778336525 @default.
- W4313488052 hasConceptScore W4313488052C63363279 @default.
- W4313488052 hasConceptScore W4313488052C65409693 @default.
- W4313488052 hasConceptScore W4313488052C71924100 @default.
- W4313488052 hasConceptScore W4313488052C72563966 @default.
- W4313488052 hasIssue "6" @default.
- W4313488052 hasLocation W43134880521 @default.
- W4313488052 hasLocation W43134880522 @default.
- W4313488052 hasOpenAccess W4313488052 @default.
- W4313488052 hasPrimaryLocation W43134880521 @default.
- W4313488052 hasRelatedWork W2003938723 @default.
- W4313488052 hasRelatedWork W2047967234 @default.
- W4313488052 hasRelatedWork W2118496982 @default.
- W4313488052 hasRelatedWork W2364998975 @default.
- W4313488052 hasRelatedWork W2369162477 @default.
- W4313488052 hasRelatedWork W2377483921 @default.
- W4313488052 hasRelatedWork W2439875401 @default.
- W4313488052 hasRelatedWork W2603773853 @default.
- W4313488052 hasRelatedWork W4238867864 @default.
- W4313488052 hasRelatedWork W2525756941 @default.
- W4313488052 hasVolume "89" @default.
- W4313488052 isParatext "false" @default.
- W4313488052 isRetracted "false" @default.
- W4313488052 workType "article" @default.