Matches in SemOpenAlex for { <https://semopenalex.org/work/W4313561034> ?p ?o ?g. }
- W4313561034 endingPage "1338.e2" @default.
- W4313561034 startingPage "1330" @default.
- W4313561034 abstract "Arch pathology represents one of the last frontiers in aortic aneurysm endovascular management. Several companies recently developed dedicated branched and fenestrated endografts specifically designed for the aortic arch, aiming to overcome some of the issues associated with standard thoracic endograft and supra-aortic vessels extra-anatomic debranching. This study aimed to evaluate early outcomes obtained with a custom-made fenestrated endograft approved for thoracic aortic aneurysms exclusion.All consecutive patients treated with the Najuta endograft (Kawasumi Laboratories, Inc, Tokyo, Japan) in Italy were enrolled prospectively and included in the study population. Anatomic characteristics and perioperative data were analyzed retrospectively. Study end points were technical success, 30-day clinical success, overall survival, supra-aortic vessel patency, endoleak, and need for reintervention or surgical conversion.Between 2018 and 2022, 76 patients received a Najuta endograft in Italy and were enrolled in the study. The median patient age was 72 years (interquartile range, 69-76 years) and 80.3% were male. Most of the patients received treatment for atherosclerotic aneurysms (80.3%); others were treated for postdissection aneurysms (7.9%), penetrating aortic ulcer (9.2%), or type I endoleak correction after previous thoracic endovascular repair (2.6%). Overall, 161 supra-aortic vessels were preserved through a dedicated fenestration. Technical success was achieved in 74 of 76 procedure (97.4%); both failures were associated with endoleak detection at final angiography (one type I and one type III endoleak). Two distal migrations occurred during the implanting procedure. Clinical success at 30 days was 94.7%. Two early reinterventions were needed within 30 days after index procedure: in one case, an aortic false lumen coils embolization was performed, because distal re-entry caused enlargement of the postdissection thoracic aneurysm. The other procedure consisted of a femoral pseudoaneurysm repair. The median follow-up was 7 months (interquartile range, 3-15 months); no supra-aortic vessel occlusions occurred and no patients needed surgical conversion.Early results suggest that, in selected patients with aortic arch pathology needing a proximal landing, an endovascular approach with the Najuta system is safe and effective, especially for those at high surgical risk. A strict follow-up with high-quality computed tomography angiography images and eventual evaluation for long-term complications is needed to confirm these initial experience findings." @default.
- W4313561034 created "2023-01-06" @default.
- W4313561034 creator A5007036466 @default.
- W4313561034 creator A5013341953 @default.
- W4313561034 creator A5015182334 @default.
- W4313561034 creator A5016722964 @default.
- W4313561034 creator A5020869832 @default.
- W4313561034 creator A5022040617 @default.
- W4313561034 creator A5028255559 @default.
- W4313561034 creator A5031332466 @default.
- W4313561034 creator A5032095264 @default.
- W4313561034 creator A5032794856 @default.
- W4313561034 creator A5035071631 @default.
- W4313561034 creator A5038380083 @default.
- W4313561034 creator A5038478948 @default.
- W4313561034 creator A5040982812 @default.
- W4313561034 creator A5045131586 @default.
- W4313561034 creator A5045570543 @default.
- W4313561034 creator A5048602368 @default.
- W4313561034 creator A5051350678 @default.
- W4313561034 creator A5054140281 @default.
- W4313561034 creator A5057353647 @default.
- W4313561034 creator A5059779283 @default.
- W4313561034 creator A5064095380 @default.
- W4313561034 creator A5066468708 @default.
- W4313561034 creator A5067071447 @default.
- W4313561034 creator A5068367620 @default.
- W4313561034 creator A5070003590 @default.
- W4313561034 creator A5070980238 @default.
- W4313561034 creator A5073573869 @default.
- W4313561034 creator A5074906609 @default.
- W4313561034 creator A5077534545 @default.
- W4313561034 creator A5085691171 @default.
- W4313561034 creator A5086475928 @default.
- W4313561034 creator A5086720970 @default.
- W4313561034 creator A5087505202 @default.
- W4313561034 creator A5089155680 @default.
- W4313561034 creator A5089258862 @default.
- W4313561034 creator A5089934590 @default.
- W4313561034 creator A5090370364 @default.
- W4313561034 date "2023-05-01" @default.
- W4313561034 modified "2023-10-05" @default.
- W4313561034 title "Preliminary results from an Italian National Registry on the outcomes of the Najuta fenestrated aortic arch endograft" @default.
- W4313561034 cites W1640791488 @default.
- W4313561034 cites W2013665787 @default.
- W4313561034 cites W2014873468 @default.
- W4313561034 cites W2020119439 @default.
- W4313561034 cites W2036738281 @default.
- W4313561034 cites W2053447127 @default.
- W4313561034 cites W2062692515 @default.
- W4313561034 cites W2088162546 @default.
- W4313561034 cites W2090099381 @default.
- W4313561034 cites W2128990111 @default.
- W4313561034 cites W2311604327 @default.
- W4313561034 cites W2420150636 @default.
- W4313561034 cites W2570738377 @default.
- W4313561034 cites W2608995041 @default.
- W4313561034 cites W2799846699 @default.
- W4313561034 cites W2805508977 @default.
- W4313561034 cites W2922427073 @default.
- W4313561034 cites W3036806399 @default.
- W4313561034 doi "https://doi.org/10.1016/j.jvs.2022.12.059" @default.
- W4313561034 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/36621617" @default.
- W4313561034 hasPublicationYear "2023" @default.
- W4313561034 type Work @default.
- W4313561034 citedByCount "3" @default.
- W4313561034 countsByYear W43135610342023 @default.
- W4313561034 crossrefType "journal-article" @default.
- W4313561034 hasAuthorship W4313561034A5007036466 @default.
- W4313561034 hasAuthorship W4313561034A5013341953 @default.
- W4313561034 hasAuthorship W4313561034A5015182334 @default.
- W4313561034 hasAuthorship W4313561034A5016722964 @default.
- W4313561034 hasAuthorship W4313561034A5020869832 @default.
- W4313561034 hasAuthorship W4313561034A5022040617 @default.
- W4313561034 hasAuthorship W4313561034A5028255559 @default.
- W4313561034 hasAuthorship W4313561034A5031332466 @default.
- W4313561034 hasAuthorship W4313561034A5032095264 @default.
- W4313561034 hasAuthorship W4313561034A5032794856 @default.
- W4313561034 hasAuthorship W4313561034A5035071631 @default.
- W4313561034 hasAuthorship W4313561034A5038380083 @default.
- W4313561034 hasAuthorship W4313561034A5038478948 @default.
- W4313561034 hasAuthorship W4313561034A5040982812 @default.
- W4313561034 hasAuthorship W4313561034A5045131586 @default.
- W4313561034 hasAuthorship W4313561034A5045570543 @default.
- W4313561034 hasAuthorship W4313561034A5048602368 @default.
- W4313561034 hasAuthorship W4313561034A5051350678 @default.
- W4313561034 hasAuthorship W4313561034A5054140281 @default.
- W4313561034 hasAuthorship W4313561034A5057353647 @default.
- W4313561034 hasAuthorship W4313561034A5059779283 @default.
- W4313561034 hasAuthorship W4313561034A5064095380 @default.
- W4313561034 hasAuthorship W4313561034A5066468708 @default.
- W4313561034 hasAuthorship W4313561034A5067071447 @default.
- W4313561034 hasAuthorship W4313561034A5068367620 @default.
- W4313561034 hasAuthorship W4313561034A5070003590 @default.
- W4313561034 hasAuthorship W4313561034A5070980238 @default.
- W4313561034 hasAuthorship W4313561034A5073573869 @default.
- W4313561034 hasAuthorship W4313561034A5074906609 @default.
- W4313561034 hasAuthorship W4313561034A5077534545 @default.