Matches in SemOpenAlex for { <https://semopenalex.org/work/W4313645071> ?p ?o ?g. }
Showing items 1 to 54 of
54
with 100 items per page.
- W4313645071 endingPage "583" @default.
- W4313645071 startingPage "582" @default.
- W4313645071 abstract "THE NUMBER OF TRANSCATHETER procedures for structural heart disease has increased dramatically over the past 10 years. According to the Society of Thoracic Surgeons-American College of Cardiology Transcatheter Valve Registry, in 2014, slightly more than 1,100 mitral valve transcatheter edge-to-edge repairs (MV TEER) and 84 transcatheter mitral valve replacements were performed. Data from 2019 estimate these numbers to be approximately 10,400 and 1,100, respectively, demonstrating a substantial increase in these types of cases.1Mack M Carroll JD Thourani V et al.Transcatheter mitral valve therapy in the United States: A report from the STS-ACC TVT Registry.J Am Coll Cardiol. 2021; 78: 2326-2353Crossref PubMed Scopus (40) Google Scholar With technologic advances in both devices and delivery systems, the spectrum of disease states and patients who can be treated with structural heart procedures has expanded widely. As such, there is an increased need for standardizing optimal imaging techniques to facilitate safe and accurate echocardiographic guidance for these complex procedures. Biplane imaging, which allows for simultaneous visualization of 2 imaging planes (typically orthogonal to one another), was described in the literature as early as 1990 in reference to its clinical application to transesophageal echocardiography (TEE).2Nanda NC Pinheiro L Sanyal RS et al.Transesophageal biplane echocardiographic imaging: Technique, planes, and clinical usefulness.Echocardiography. 1990; 7: 771-788Crossref PubMed Scopus (61) Google Scholar This imaging modality has been fundamental to the assessment of cardiac structures during both the planning and implementation stages of transcatheter procedures for many years. In the American Society of Echocardiography's Recommended Standards for the Performance of Transesophageal Echocardiographic Screening for Structural Heart Intervention, Hahn et al. demonstrated the ubiquitous applications of biplane imaging with respect to the assessment of various cardiac structures.3Hahn RT Saric M Faletra FF et al.Recommended standards for the performance of transesophageal echocardiographic screening for structural heart intervention: From the American Society of Echocardiography.J Am Soc Echocardiogr. 2022; 35 (Erratum in: J Am Soc Echocardiogr 2022;35:447): 1-76Abstract Full Text Full Text PDF PubMed Scopus (37) Google Scholar As echocardiographic imaging techniques such as 3-dimensional (3D) data acquisition and software imaging packages that enable live manipulation of a dataset have developed, echocardiographers are less and less reliant on biplane imaging to interrogate cardiac structures. One such example of this software is multiplanar reconstruction (MPR), in which a 3D volume enables simultaneous visualization of axial, coronal, and sagittal projections that can be adjusted within the dataset. In their recent publication, “Real-Time Multiplanar Reconstruction Imaging Using 3D Transesophageal Echocardiography in Structural Heart Interventions,” Wollborn et al. described the advantages of this technique's application to guiding transcatheter structural heart procedures, including MV TEER, tricuspid valve TEER, left atrial appendage (LAA) occlusion device implantation, and laceration of the anterior mitral leaflet to prevent outflow obstruction.4Wollborn J, Schuler A, Sheu RD, et al. Real-time multiplanar reconstruction imaging using 3-dimensional transesophageal echocardiography in structural heart interventions. J Cardiothorac Vasc Anesth. 2023;37:570-581. Accessed December 10, 2022.Google Scholar One of the main advantages of using live 3D MPR, as discussed by Wollborn et al., is the ability to view structures in the axial, coronal, and sagittal planes simultaneously, which may allow for a more detailed assessment of cardiac structures compared to biplane alone. The MPR allows the echocardiographer to visualize 3 distinct 2-dimensional (2D) slices of a 3D volume and actively manipulate them to optimize a region of interest. One example of where this technique is especially useful is for patients undergoing MV TEER who do not have a classic A2-P2 regurgitant lesion. When the regurgitant jet arises more from the anterior-lateral or posterior-medial segment of the valve, a standard 2D biplane across the mitral valve commissural axis will not be helpful, as the device clip arms will be out of plane.4Wollborn J, Schuler A, Sheu RD, et al. Real-time multiplanar reconstruction imaging using 3-dimensional transesophageal echocardiography in structural heart interventions. J Cardiothorac Vasc Anesth. 2023;37:570-581. Accessed December 10, 2022.Google Scholar In 3D MPR, the 2D projections can be adjusted to better visualize the clip and direct the interventionalist to not only ensure it is placed over the pathologic segment of the valve but also that it is perpendicular to the line of coaptation. Additionally, simultaneous visualization of the 3D volume with the 2D slices is also advantageous during MV TEER multiclip procedures when it is critical to see the spatial relationship between the first clip during the placement of the second.4Wollborn J, Schuler A, Sheu RD, et al. Real-time multiplanar reconstruction imaging using 3-dimensional transesophageal echocardiography in structural heart interventions. J Cardiothorac Vasc Anesth. 2023;37:570-581. Accessed December 10, 2022.Google Scholar Real-time MPR also has several advantages over biplane imaging with respect to examining the LAA for occlusion device placement. Using conventional 2D methods, landing zone and depth measurements are obtained at a set of sequential angles to ensure appropriate device sizing in all dimensions, although foreshortening or inappropriate angulation can yield inaccurate measurements. Using real-time 3D MPR, the echocardiographer can align the MPR axes to display not only the septal-lateral and anteroposterior dimensions of the LAA, but also the landing zone simultaneously, which can be especially helpful in appendages with an ovoid ostium.4Wollborn J, Schuler A, Sheu RD, et al. Real-time multiplanar reconstruction imaging using 3-dimensional transesophageal echocardiography in structural heart interventions. J Cardiothorac Vasc Anesth. 2023;37:570-581. Accessed December 10, 2022.Google Scholar Additionally, the same technical principles can be applied to a post-deployment assessment of LAA occlusion device implantation, such that the MPR axes traverse the device's central pin to display accurate dimensions for compression measurements without the risk of foreshortening. Using live 3D MPR also may provide a safety advantage compared to conventional 2D biplane imaging methods. It has been demonstrated that increased TEE probe manipulation times correlate well with increased risk for major gastrointestinal complications, including gastroesophageal bleeding or perforation.5Patel KM Desai RG Trivedi K et al.Complications of transesophageal echocardiography: A review of injuries, risk factors, and management.J Cardiothorac Vasc Anesth. 2022; 36: 3292-3302Abstract Full Text Full Text PDF PubMed Scopus (5) Google Scholar Wollborn et al. proposed that using live 3D MPR reduces the need to continuously and repeatedly maneuver the TEE probe between the esophageal and gastric windows due to the ability to manipulate the 2D projections within the 3D volume dataset. This is especially true with regard to the tricuspid valve TEER procedures, during which it is recommended to use multiple transgastric and mid- and/or deep esophageal views for evaluation of leaflet morphology, valvular apparatus assessment, and procedural guidance.3Hahn RT Saric M Faletra FF et al.Recommended standards for the performance of transesophageal echocardiographic screening for structural heart intervention: From the American Society of Echocardiography.J Am Soc Echocardiogr. 2022; 35 (Erratum in: J Am Soc Echocardiogr 2022;35:447): 1-76Abstract Full Text Full Text PDF PubMed Scopus (37) Google Scholar Although the use of live 3D MPR offers several advantages over conventional biplane imaging, its use also has several limitations. Temporal and spatial resolution are both significantly reduced with 3D imaging compared to 2D. As a result, regulating sector size for optimal image acquisition must be considered to obtain reliable qualitative and quantitative information. Similarly, the image window size is significantly reduced when using 3D MPR as compared to 2D, due to a 4-pane layout required to visualize each plane simultaneously, which may affect image interpretation. Lastly, there is a steep learning curve with respect to the use of this technology, not only for echocardiographers but also for interventionalists who will be relying on potentially nonstandard views for procedural guidance. It is, therefore, important to ensure familiarity with this imaging modality among the entire team prior to incorporating it into practice. In their detailed discussion of live 3D MPR's application to various structural heart procedures, Wollborn et al. effectively described the benefits of this imaging modality over conventional 2D imaging. Although the most recent American Society of Echocardiography guidelines published by Hahn et al. provide echocardiographers with a framework to perform a comprehensive preprocedural structural assessment, it, unfortunately, does not discuss in detail the optimal intraprocedural imaging techniques that may facilitate these procedures.3Hahn RT Saric M Faletra FF et al.Recommended standards for the performance of transesophageal echocardiographic screening for structural heart intervention: From the American Society of Echocardiography.J Am Soc Echocardiogr. 2022; 35 (Erratum in: J Am Soc Echocardiogr 2022;35:447): 1-76Abstract Full Text Full Text PDF PubMed Scopus (37) Google Scholar With the growing number and complexity of both procedures and patients, there is an emerging need for creating a standardized intraoperative imaging approach using techniques such as 3D MPR to provide safe, reliable, and easy-to-replicate ultrasound-based procedural guidance. None. Real-Time Multiplanar Reconstruction Imaging Using 3-Dimensional Transesophageal Echocardiography in Structural Heart InterventionsJournal of Cardiothoracic and Vascular AnesthesiaVol. 37Issue 4PreviewTHE VOLUME OF interventions for structural heart disease (SHD) is continuously increasing. According to the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry, the number of mitral valve transcatheter edge-to-edge repair (MV-TEER) cases has increased almost 10-fold from 2014 to 2019.1 Among the 2 million patients in the United States affected by mitral regurgitation (MR), MV-TEER has offered a less-invasive approach compared to surgery, showing promising clinical outcomes after careful patient selection. Full-Text PDF" @default.
- W4313645071 created "2023-01-07" @default.
- W4313645071 creator A5004608297 @default.
- W4313645071 creator A5067137008 @default.
- W4313645071 date "2023-04-01" @default.
- W4313645071 modified "2023-09-29" @default.
- W4313645071 title "Real-Time Multiplanar Reconstruction As a Standard Imaging Modality for Structural Heart Procedural Guidance" @default.
- W4313645071 cites W2107275249 @default.
- W4313645071 cites W3185321037 @default.
- W4313645071 cites W3210887269 @default.
- W4313645071 cites W4210961516 @default.
- W4313645071 cites W4309046909 @default.
- W4313645071 doi "https://doi.org/10.1053/j.jvca.2022.12.035" @default.
- W4313645071 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/36717314" @default.
- W4313645071 hasPublicationYear "2023" @default.
- W4313645071 type Work @default.
- W4313645071 citedByCount "0" @default.
- W4313645071 crossrefType "journal-article" @default.
- W4313645071 hasAuthorship W4313645071A5004608297 @default.
- W4313645071 hasAuthorship W4313645071A5067137008 @default.
- W4313645071 hasBestOaLocation W43136450711 @default.
- W4313645071 hasConcept C126838900 @default.
- W4313645071 hasConcept C154945302 @default.
- W4313645071 hasConcept C19527891 @default.
- W4313645071 hasConcept C2780226545 @default.
- W4313645071 hasConcept C41008148 @default.
- W4313645071 hasConcept C71924100 @default.
- W4313645071 hasConceptScore W4313645071C126838900 @default.
- W4313645071 hasConceptScore W4313645071C154945302 @default.
- W4313645071 hasConceptScore W4313645071C19527891 @default.
- W4313645071 hasConceptScore W4313645071C2780226545 @default.
- W4313645071 hasConceptScore W4313645071C41008148 @default.
- W4313645071 hasConceptScore W4313645071C71924100 @default.
- W4313645071 hasIssue "4" @default.
- W4313645071 hasLocation W43136450711 @default.
- W4313645071 hasLocation W43136450712 @default.
- W4313645071 hasOpenAccess W4313645071 @default.
- W4313645071 hasPrimaryLocation W43136450711 @default.
- W4313645071 hasRelatedWork W141524600 @default.
- W4313645071 hasRelatedWork W1754602832 @default.
- W4313645071 hasRelatedWork W1841185769 @default.
- W4313645071 hasRelatedWork W2011093510 @default.
- W4313645071 hasRelatedWork W2049214470 @default.
- W4313645071 hasRelatedWork W2072926321 @default.
- W4313645071 hasRelatedWork W2155887765 @default.
- W4313645071 hasRelatedWork W2902148150 @default.
- W4313645071 hasRelatedWork W2972737346 @default.
- W4313645071 hasRelatedWork W4230630428 @default.
- W4313645071 hasVolume "37" @default.
- W4313645071 isParatext "false" @default.
- W4313645071 isRetracted "false" @default.
- W4313645071 workType "article" @default.