- W4319073089 abstract "There is significant published evidence calling into question the utility and accuracy of manual pulse palpation during cardiopulmonary resuscitation (CPR) for determining return of spontaneous circulation (ROSC). 1 Nakagawa Y. Inokuchi S. Morita S. et al. Accuracy of pulse checks in terms of basic life support by lifesavers, as lay persons. Circ J. 2010; 74: 1895-1899https://doi.org/10.1253/circj.cj-10-0081. 5 Crossref PubMed Scopus (0) Google Scholar , 2 Eberle B. Dick W.F. Schneider T. Wisser G. Doetsch S. Tzanova I. Checking the carotid pulse check: diagnostic accuracy of first responders in patients with and without a pulse. Resuscitation. 1996; 33: 107-116https://doi.org/10.1016/s0300-9572(96)01016-7. 6 Crossref PubMed Scopus (0) Google Scholar , 3 Dick W.F. Eberle B. Wisser G. Schneider T. The carotid pulse check revisited: What if there is no pulse?. Critical Care Med. 2000; 28: N183 Crossref PubMed Scopus (59) Google Scholar Despite this clinical equipoise, manual palpation remains the primary modality for determination of ROSC and is still the only method recommended in the current adult basic and advanced life support guidelines. 4 Panchal A.R. Bartos J.A. Cabañas J.G. et al. Part 3: Adult Basic and Advanced Life Support: 2020 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2020; 142: S366-S468https://doi.org/10.1161/CIR.0000000000000916 Crossref PubMed Scopus (706) Google Scholar There is growing evidence that bedside ultrasound may be a more accurate alternative to manual pulse palpation in a variety of different modalities; transthoracic echocardiography (TTE), transesophageal echocardiography (TEE) and color arterial doppler. 5 Zengin S. Gümüşboğa H. Sabak M. Eren Ş.H. Altunbas G. Al B. Comparison of manual pulse palpation, cardiac ultrasonography and Doppler ultrasonography to check the pulse in cardiopulmonary arrest patients. Resuscitation. 2018; 133: 59-64https://doi.org/10.1016/j.resuscitation.2018.09.018 Abstract Full Text Full Text PDF PubMed Scopus (29) Google Scholar , 6 Badra K. Coutin A. Simard R. Pinto R. Lee J.S. Chenkin J. The POCUS pulse check: A randomized controlled crossover study comparing pulse detection by palpation versus by point-of-care ultrasound. Resuscitation. 2019; 139: 17-23https://doi.org/10.1016/j.resuscitation.2019.03.009 Abstract Full Text Full Text PDF PubMed Scopus (21) Google Scholar , 7 Fair 3rd, J. Mallin M.P. Adler A. et al. Transesophageal Echocardiography During Cardiopulmonary Resuscitation Is Associated With Shorter Compression Pauses Compared With Transthoracic Echocardiography. Ann Emerg Med. 2019; 73: 610-616https://doi.org/10.1016/j.annemergmed.2019.01.018 Abstract Full Text Full Text PDF PubMed Scopus (40) Google Scholar , 8 Cohen A.L. et al. Femoral artery Doppler ultrasound is more accurate than manual palpation for pulse detection in cardiac arrest. Resuscitation. 2022; 173: 156-165https://doi.org/10.1016/j.resuscitation.2022.01.030 Abstract Full Text Full Text PDF PubMed Scopus (14) Google Scholar TTE has proven to be feasible, though has been criticized for delaying time off the chest due to higher technical skill required to obtain images. 9 Balderston J.R. You A.X. Evans D.P. Taylor L.A. Gertz Z.M. Feasibility of focused cardiac ultrasound during cardiac arrest in the emergency department. Cardiovasc Ultrasound. 2021; 19: 19https://doi.org/10.1186/s12947-021-00252-3 Crossref PubMed Scopus (7) Google Scholar , 10 Gaspari R. Harvey J. DiCroce C. et al. Echocardiographic pre-pause imaging and identifying the acoustic window during CPR reduces CPR pause time during ACLS - A prospective Cohort Study. Resusc Plus. 2021; 6100094https://doi.org/10.1016/j.resplu.2021.100094 Crossref Scopus (11) Google Scholar TEE mitigates some of this concern, though it is not practical in all practice environments primarily due to transducer availability and provider credentialing to perform this exam. 7 Fair 3rd, J. Mallin M.P. Adler A. et al. Transesophageal Echocardiography During Cardiopulmonary Resuscitation Is Associated With Shorter Compression Pauses Compared With Transthoracic Echocardiography. Ann Emerg Med. 2019; 73: 610-616https://doi.org/10.1016/j.annemergmed.2019.01.018 Abstract Full Text Full Text PDF PubMed Scopus (40) Google Scholar Doppler ultrasound of large arteries however is easy to perform and could prove to be a replacement for manual palpation. Doppler ultrasound peak systolic velocity versus end tidal carbon dioxide during pulse checks in cardiac arrestResuscitationVol. 183PreviewAn accurate, non-invasive measure of return of spontaneous circulation (ROSC) is needed to improve management of cardiac arrest patients. Full-Text PDF" @default.
- W4319073089 created "2023-02-04" @default.
- W4319073089 creator A5030403147 @default.
- W4319073089 creator A5047909325 @default.
- W4319073089 date "2023-03-01" @default.
- W4319073089 modified "2023-09-27" @default.
- W4319073089 title "The use of spectral Doppler to detect return of spontaneous circulation, a novel alternative to manual palpation" @default.
- W4319073089 cites W1975661742 @default.
- W4319073089 cites W2018271577 @default.
- W4319073089 cites W2087922724 @default.
- W4319073089 cites W2893723447 @default.
- W4319073089 cites W2912476257 @default.
- W4319073089 cites W2924069434 @default.
- W4319073089 cites W2967487143 @default.
- W4319073089 cites W3025731237 @default.
- W4319073089 cites W3134479045 @default.
- W4319073089 cites W3155286684 @default.
- W4319073089 cites W3165269419 @default.
- W4319073089 cites W4205698737 @default.
- W4319073089 cites W4210266625 @default.
- W4319073089 cites W4284881435 @default.
- W4319073089 cites W4315881655 @default.
- W4319073089 doi "https://doi.org/10.1016/j.resuscitation.2023.109717" @default.
- W4319073089 hasPubMedId "https://pubmed.ncbi.nlm.nih.gov/36740092" @default.
- W4319073089 hasPublicationYear "2023" @default.
- W4319073089 type Work @default.
- W4319073089 citedByCount "0" @default.
- W4319073089 crossrefType "journal-article" @default.
- W4319073089 hasAuthorship W4319073089A5030403147 @default.
- W4319073089 hasAuthorship W4319073089A5047909325 @default.
- W4319073089 hasConcept C141071460 @default.
- W4319073089 hasConcept C17744445 @default.
- W4319073089 hasConcept C194828623 @default.
- W4319073089 hasConcept C199539241 @default.
- W4319073089 hasConcept C2777055891 @default.
- W4319073089 hasConcept C2778165595 @default.
- W4319073089 hasConcept C2778619729 @default.
- W4319073089 hasConcept C2779084015 @default.
- W4319073089 hasConcept C2779473830 @default.
- W4319073089 hasConcept C2781167935 @default.
- W4319073089 hasConcept C71924100 @default.
- W4319073089 hasConcept C83867959 @default.
- W4319073089 hasConceptScore W4319073089C141071460 @default.
- W4319073089 hasConceptScore W4319073089C17744445 @default.
- W4319073089 hasConceptScore W4319073089C194828623 @default.
- W4319073089 hasConceptScore W4319073089C199539241 @default.
- W4319073089 hasConceptScore W4319073089C2777055891 @default.
- W4319073089 hasConceptScore W4319073089C2778165595 @default.
- W4319073089 hasConceptScore W4319073089C2778619729 @default.
- W4319073089 hasConceptScore W4319073089C2779084015 @default.
- W4319073089 hasConceptScore W4319073089C2779473830 @default.
- W4319073089 hasConceptScore W4319073089C2781167935 @default.
- W4319073089 hasConceptScore W4319073089C71924100 @default.
- W4319073089 hasConceptScore W4319073089C83867959 @default.
- W4319073089 hasLocation W43190730891 @default.
- W4319073089 hasLocation W43190730892 @default.
- W4319073089 hasOpenAccess W4319073089 @default.
- W4319073089 hasPrimaryLocation W43190730891 @default.
- W4319073089 hasRelatedWork W1986684895 @default.
- W4319073089 hasRelatedWork W2050939749 @default.
- W4319073089 hasRelatedWork W2067417982 @default.
- W4319073089 hasRelatedWork W2070366986 @default.
- W4319073089 hasRelatedWork W2092210791 @default.
- W4319073089 hasRelatedWork W2095562355 @default.
- W4319073089 hasRelatedWork W2153961831 @default.
- W4319073089 hasRelatedWork W3159126940 @default.
- W4319073089 hasRelatedWork W4309842643 @default.
- W4319073089 hasRelatedWork W2124960949 @default.
- W4319073089 hasVolume "184" @default.
- W4319073089 isParatext "false" @default.
- W4319073089 isRetracted "false" @default.
- W4319073089 workType "article" @default.