- W4377015830 endingPage "S545" @default.
- W4377015830 startingPage "S545" @default.
- W4377015830 abstract "Atrial fibrillation (AF) is commonly detected by remote monitoring of implanted devices. A common question is whether to start anticoagulation in patients with detected AF at risk of stroke. However, the cause of AF is rarely able to be diagnosed or corrected. Repetitive non-reentrant ventriculoatrial synchrony (RNRVAS) is a pacemaker mediated arrhythmia that can occur in patients with intact ventriculoatrial (VA) conduction. Ventricular pacing with retrograde atrial activation that falls within the PVARP is followed by atrial pacing, often delivered while the atrium is refractory. Retrograde atrial activation from the next ventricular paced beat facilitates a repetitive (but non-reentrant) process. Atrial arrhythmias may occasionally result. To highlight the importance of recognizing and correcting RNRVAS as a cause of device-mediated arrhythmia. NA A 68-year-old man with hypertension and sinus node dysfunction underwent dual chamber pacemaker implant (Abbott Assurity). Device interrogation 5-years later showed repetitive episodes of AF that might warrant anticoagulation. Device tracings revealed RNRVAS: retrograde atrial activation falling in PVARP, followed by competitive sensor driven atrial pacing with non-capture, until a captured atrial event initiated AF (Figure, red arrow). Anticoagulation was deferred in favor of device reprogramming, including: 1) reduction in the lower rate; 2) reduction in paced AV delay; and 3) disabling of rate-response. The patient had no further AF episodes. RNRVAS is largely benign but may facilitate initiation of AF or other supraventricular arrhythmias that lead to symptoms or inappropriate therapy. Both RNRVAS and device-triggered AF may be underrecognized. Current devices do not have automatic diagnostic or treatment algorithms. Therefore, it is important to be aware of RNRVAS triggered AF in patients with a dual-chamber device and newly diagnosed AF. RNRVAS tends to occur with a long programmed AV delay (such as is often used to avoid ventricular pacing) and a relatively fast lower rate. Reprogramming to shorten the AV delay, decrease the lower rate or decrease the PVARP are the primary methods of correction. Awareness of pacemaker triggered AF may help avoid inappropriate initiation of anticoagulation or other therapies." @default.
- W4377015830 created "2023-05-19" @default.
- W4377015830 creator A5014626869 @default.
- W4377015830 creator A5070486898 @default.
- W4377015830 date "2023-05-01" @default.
- W4377015830 modified "2023-10-01" @default.
- W4377015830 title "PO-04-057 ATRIAL FIBRILLATION CURED BY PACEMAKER REPROGRAMMING" @default.
- W4377015830 doi "https://doi.org/10.1016/j.hrthm.2023.03.1165" @default.
- W4377015830 hasPublicationYear "2023" @default.
- W4377015830 type Work @default.
- W4377015830 citedByCount "0" @default.
- W4377015830 crossrefType "journal-article" @default.
- W4377015830 hasAuthorship W4377015830A5014626869 @default.
- W4377015830 hasAuthorship W4377015830A5070486898 @default.
- W4377015830 hasBestOaLocation W43770158301 @default.
- W4377015830 hasConcept C114021368 @default.
- W4377015830 hasConcept C126322002 @default.
- W4377015830 hasConcept C164705383 @default.
- W4377015830 hasConcept C2778292772 @default.
- W4377015830 hasConcept C2779161974 @default.
- W4377015830 hasConcept C2910597771 @default.
- W4377015830 hasConcept C71924100 @default.
- W4377015830 hasConceptScore W4377015830C114021368 @default.
- W4377015830 hasConceptScore W4377015830C126322002 @default.
- W4377015830 hasConceptScore W4377015830C164705383 @default.
- W4377015830 hasConceptScore W4377015830C2778292772 @default.
- W4377015830 hasConceptScore W4377015830C2779161974 @default.
- W4377015830 hasConceptScore W4377015830C2910597771 @default.
- W4377015830 hasConceptScore W4377015830C71924100 @default.
- W4377015830 hasIssue "5" @default.
- W4377015830 hasLocation W43770158301 @default.
- W4377015830 hasOpenAccess W4377015830 @default.
- W4377015830 hasPrimaryLocation W43770158301 @default.
- W4377015830 hasRelatedWork W1998746965 @default.
- W4377015830 hasRelatedWork W2047344647 @default.
- W4377015830 hasRelatedWork W2078105309 @default.
- W4377015830 hasRelatedWork W2085641168 @default.
- W4377015830 hasRelatedWork W2137189747 @default.
- W4377015830 hasRelatedWork W2156191290 @default.
- W4377015830 hasRelatedWork W2266993741 @default.
- W4377015830 hasRelatedWork W2409916269 @default.
- W4377015830 hasRelatedWork W3030464425 @default.
- W4377015830 hasRelatedWork W4210980471 @default.
- W4377015830 hasVolume "20" @default.
- W4377015830 isParatext "false" @default.
- W4377015830 isRetracted "false" @default.
- W4377015830 workType "article" @default.