Matches in SemOpenAlex for { <https://semopenalex.org/work/W4385271470> ?p ?o ?g. }
Showing items 1 to 68 of
68
with 100 items per page.
- W4385271470 endingPage "45" @default.
- W4385271470 startingPage "45" @default.
- W4385271470 abstract "Introduction Osteogenesis imperfect (OI) is a geno- and phenotypically heterogeneous group of congenital collagen disorders characterized by fragility and microfractures resulting in long bone deformities. OI can lead to progressive femoral coxa vara from bone and muscular imbalance and continuous microfracture about the proximal femur. If left untreated, patients develop Trendelenburg gait, leg length discrepancy, further stress fracture and acute fracture at the apex of the deformity, impingement and hip joint degeneration. In the OI patient, femoral coxa vara cannot be treated in isolation and consideration must be given to protecting the whole bone with the primary goal of verticalization and improved biomechanical stability to allow early loading, safe standing, re-orientation of the physis and avoidance of untreated sequelae. Implant constructs should therefore be designed to accommodate and protect the whole bone. The normal paediatric femoral neck shaft angle (FNSA) ranges from 135 to 145 degrees. In OI the progressive pathomechanical changes result in FNSA of significantly less than 120 degrees and decreased Hilgenreiner epiphyseal angles (HEA). Proximal femoral valgus osteotomy is considered the standard surgical treatment for coxa vara and multiple surgical techniques have been described, each with their associated complications. In this paper we present the novel technique of controlling femoral version and coronal alignment using a tubular plate and long bone protection with the use of teleoscoping rods. Methodology After the decision to operate had been made, a CT scan of the femur was performed. A 1:1 scale 3D printed model (AXIAL3D, Belfast, UK) was made from the CT scan to allow for accurate implant templating and osteotomy planning. In all cases a subtrochanteric osteotomy was performed and fixed using a pre-bent 3.5 mm 1/3 tubular plate. The plate was bent to allow one end to be inserted into the proximal femur to act as a blade. A channel into the femoral neck was opened using a flat osteotome. The plate was then tapped into the femoral neck to the predetermined position. The final position needed to allow one of the plate holes to accommodate the growing rod. This had to be determined pre operatively using the 3D printed model and the implants. The femoral canal was reamed, and the growing rod was placed in the femur, passing through the hole in the plate to create a construct that could effectively protect both the femoral neck and the full length of the shaft. The distal part of the plate was then fixed to the shaft using eccentric screws around the nail to complete the construct. Results Three children ages 5,8 and 13 underwent the procedure. Five coxa vara femurs have undergone this technique with follow-up out to 62 months (41–85 months) from surgery. Improvements in the femoral neck shaft angle (FNSA) were av. 18 o (10–38 o ) with pre-op coxa vara FNSA av. 99 o (range 87–114 o ) and final FNSA 117 o (105–125 o ). Hilgenreiner's epiphyseal angle was improved by av. 29 o (2–58 o ). However only one hip was restored to <25 o . In the initial technique employed for 3 hips, the plates were left short in the neck to avoid damaging the physis. This resulted in 2 of 3 hips fracturing through the femoral neck above the plate at approximately 1 year. There were revisions of the 3 hips to longer plates to prevent intra-capsular stress riser. All osteotomies united and both intracapsular fractures healed. No further fractures have occurred within the protected femurs and no other repeat operations have been required. Conclusions Surgical correction of the OI coxa vara hip is complex. Bone mineral density, multiplanar deformity, a desire to maintain physeal growth and protection of the whole bone all play a role in the surgeon's decision making process. Following modifications, this technique demonstrates a novel method in planning and control of multiplanar proximal femoral deformity, resulting in restoration of the FNSA to a more appropriate anatomical alignment, preventing long bone fracture and improved femoral verticalization in the medium term follow-up." @default.
- W4385271470 created "2023-07-27" @default.
- W4385271470 creator A5006620096 @default.
- W4385271470 creator A5009343093 @default.
- W4385271470 creator A5070131742 @default.
- W4385271470 creator A5078946388 @default.
- W4385271470 date "2023-06-01" @default.
- W4385271470 modified "2023-10-04" @default.
- W4385271470 title "THE BELFAST TECHNIQUE FOR DEFORMITY CORRECTION OF FEMORAL COXA VARA IN OSTEOGENESIS IMPERFECTA: A NOVEL PLANNING AND SURGICAL TECHNIQUE" @default.
- W4385271470 doi "https://doi.org/10.1302/1358-992x.2023.10.045" @default.
- W4385271470 hasPublicationYear "2023" @default.
- W4385271470 type Work @default.
- W4385271470 citedByCount "0" @default.
- W4385271470 crossrefType "journal-article" @default.
- W4385271470 hasAuthorship W4385271470A5006620096 @default.
- W4385271470 hasAuthorship W4385271470A5009343093 @default.
- W4385271470 hasAuthorship W4385271470A5070131742 @default.
- W4385271470 hasAuthorship W4385271470A5078946388 @default.
- W4385271470 hasConcept C105702510 @default.
- W4385271470 hasConcept C134018914 @default.
- W4385271470 hasConcept C13483470 @default.
- W4385271470 hasConcept C141071460 @default.
- W4385271470 hasConcept C2775854910 @default.
- W4385271470 hasConcept C2776389721 @default.
- W4385271470 hasConcept C2776541429 @default.
- W4385271470 hasConcept C2777668750 @default.
- W4385271470 hasConcept C2779982284 @default.
- W4385271470 hasConcept C2780554211 @default.
- W4385271470 hasConcept C2780847666 @default.
- W4385271470 hasConcept C2781017183 @default.
- W4385271470 hasConcept C2781041657 @default.
- W4385271470 hasConcept C29694066 @default.
- W4385271470 hasConcept C71924100 @default.
- W4385271470 hasConceptScore W4385271470C105702510 @default.
- W4385271470 hasConceptScore W4385271470C134018914 @default.
- W4385271470 hasConceptScore W4385271470C13483470 @default.
- W4385271470 hasConceptScore W4385271470C141071460 @default.
- W4385271470 hasConceptScore W4385271470C2775854910 @default.
- W4385271470 hasConceptScore W4385271470C2776389721 @default.
- W4385271470 hasConceptScore W4385271470C2776541429 @default.
- W4385271470 hasConceptScore W4385271470C2777668750 @default.
- W4385271470 hasConceptScore W4385271470C2779982284 @default.
- W4385271470 hasConceptScore W4385271470C2780554211 @default.
- W4385271470 hasConceptScore W4385271470C2780847666 @default.
- W4385271470 hasConceptScore W4385271470C2781017183 @default.
- W4385271470 hasConceptScore W4385271470C2781041657 @default.
- W4385271470 hasConceptScore W4385271470C29694066 @default.
- W4385271470 hasConceptScore W4385271470C71924100 @default.
- W4385271470 hasIssue "SUPP_10" @default.
- W4385271470 hasLocation W43852714701 @default.
- W4385271470 hasOpenAccess W4385271470 @default.
- W4385271470 hasPrimaryLocation W43852714701 @default.
- W4385271470 hasRelatedWork W2415177695 @default.
- W4385271470 hasRelatedWork W2797469417 @default.
- W4385271470 hasRelatedWork W2810650812 @default.
- W4385271470 hasRelatedWork W2949295839 @default.
- W4385271470 hasRelatedWork W3029366229 @default.
- W4385271470 hasRelatedWork W3029932939 @default.
- W4385271470 hasRelatedWork W3109843062 @default.
- W4385271470 hasRelatedWork W3154305502 @default.
- W4385271470 hasRelatedWork W4322770788 @default.
- W4385271470 hasRelatedWork W2162902802 @default.
- W4385271470 hasVolume "105-B" @default.
- W4385271470 isParatext "false" @default.
- W4385271470 isRetracted "false" @default.
- W4385271470 workType "article" @default.