Matches in SemOpenAlex for { <https://semopenalex.org/work/W4387062644> ?p ?o ?g. }
Showing items 1 to 57 of
57
with 100 items per page.
- W4387062644 endingPage "243" @default.
- W4387062644 startingPage "242" @default.
- W4387062644 abstract "PURPOSE Following lower-extremity injury, non-weight bearing recovery is often required. A hands-free, knee crutch allows ambulation with increased manual freedom compared to a traditional axillary crutch. Beyond use as an assistive device, the knee crutch may serve as an analog to a fixed knee prosthetic for transfemoral amputation. Patients in both scenarios typically express modified balance and ambulation as they learn to accommodate the new device. The present study seeks to quantify initial balance impairment to determine best practice for clinical instructions for such devices. METHODS Twenty young healthy participants volunteered. Following informed consent they completed a baseline series of balance assessments, were fit with the knee crutch (iWalk), provided supported ambulation practice, and completed an experimental series of balance assessments wearing the knee crutch. All balance assessments were completed using the BTrackS force plate with Balance Assess software. The Balance and Falls Risk (FR) protocol included 4 trials, 20s each, with eyes closed and the instruction to remain still throughout the trial. A measure of path length and fall risk percentile are provided by the software. The Limits of Stability (LOS) protocol included 3 trials, 20s each, with eyes open and the instruction to cover the largest area of sway possible. Visual biofeedback was provided. A measure of total sway area is provided by the software, as well as quadrant areas from which a lateral bias score was calculated. Paired t-tests compared baseline to experimental assessments. RESULTS FR path length increased from 22.7 cm to 50.2 cm (p < 0.0001), while the percentile decreased from the 51.6 percentile to the 2.6 percentile (p < 0.0001). LOS total area decreased from 403.5 cm^2 to 181.1 cm^2 (p < 0.0001). Lateral bias during LOS decreased from -1.1% to -40.9% (p = 0.0003). CONCLUSION The results of this study indicate clear, large insults to balance ability when using the knee crutch for the first time. This includes increased sway in a “stand still” task, decreased excursion in a “lean most” task, as well as an onset of lateral bias away from the crutched leg. In contrast, all participants reported sufficient balance confidence to attempt independent ambulation while using the knee crutch. Longitudinal follow-up is warranted." @default.
- W4387062644 created "2023-09-27" @default.
- W4387062644 creator A5002102525 @default.
- W4387062644 creator A5039333207 @default.
- W4387062644 creator A5056065958 @default.
- W4387062644 creator A5061222026 @default.
- W4387062644 creator A5068596266 @default.
- W4387062644 creator A5092946826 @default.
- W4387062644 date "2023-09-01" @default.
- W4387062644 modified "2023-09-27" @default.
- W4387062644 title "Balance Assessments During Acute Use Of A Knee Crutch Device" @default.
- W4387062644 doi "https://doi.org/10.1249/01.mss.0000981980.03527.14" @default.
- W4387062644 hasPublicationYear "2023" @default.
- W4387062644 type Work @default.
- W4387062644 citedByCount "0" @default.
- W4387062644 crossrefType "journal-article" @default.
- W4387062644 hasAuthorship W4387062644A5002102525 @default.
- W4387062644 hasAuthorship W4387062644A5039333207 @default.
- W4387062644 hasAuthorship W4387062644A5056065958 @default.
- W4387062644 hasAuthorship W4387062644A5061222026 @default.
- W4387062644 hasAuthorship W4387062644A5068596266 @default.
- W4387062644 hasAuthorship W4387062644A5092946826 @default.
- W4387062644 hasBestOaLocation W43870626441 @default.
- W4387062644 hasConcept C127413603 @default.
- W4387062644 hasConcept C168031717 @default.
- W4387062644 hasConcept C1862650 @default.
- W4387062644 hasConcept C2778345045 @default.
- W4387062644 hasConcept C66938386 @default.
- W4387062644 hasConcept C71924100 @default.
- W4387062644 hasConcept C99508421 @default.
- W4387062644 hasConceptScore W4387062644C127413603 @default.
- W4387062644 hasConceptScore W4387062644C168031717 @default.
- W4387062644 hasConceptScore W4387062644C1862650 @default.
- W4387062644 hasConceptScore W4387062644C2778345045 @default.
- W4387062644 hasConceptScore W4387062644C66938386 @default.
- W4387062644 hasConceptScore W4387062644C71924100 @default.
- W4387062644 hasConceptScore W4387062644C99508421 @default.
- W4387062644 hasIssue "9S" @default.
- W4387062644 hasLocation W43870626441 @default.
- W4387062644 hasOpenAccess W4387062644 @default.
- W4387062644 hasPrimaryLocation W43870626441 @default.
- W4387062644 hasRelatedWork W2087504985 @default.
- W4387062644 hasRelatedWork W2141368385 @default.
- W4387062644 hasRelatedWork W2412848359 @default.
- W4387062644 hasRelatedWork W2415398665 @default.
- W4387062644 hasRelatedWork W2594350041 @default.
- W4387062644 hasRelatedWork W2896763516 @default.
- W4387062644 hasRelatedWork W4309505858 @default.
- W4387062644 hasRelatedWork W4311960939 @default.
- W4387062644 hasRelatedWork W4372348156 @default.
- W4387062644 hasRelatedWork W2255672976 @default.
- W4387062644 hasVolume "55" @default.
- W4387062644 isParatext "false" @default.
- W4387062644 isRetracted "false" @default.
- W4387062644 workType "article" @default.