Matches in SemOpenAlex for { <https://semopenalex.org/work/W63788104> ?p ?o ?g. }
Showing items 1 to 47 of
47
with 100 items per page.
- W63788104 abstract "L'experience LHCb sera installee sur le futur accelerateur LHC du CERN. LHCb est un spectrometre a un bras consacre aux mesures de precision de la violation CP et a l'etude des desintegrations rares des particules qui contiennent un quark b. Actuellement LHCb se trouve dans la phase finale de recherche et developpement et de conception. La construction a deja commence pour l'aimant et les calorimetres. Dans le Modele Standard, la violation CP est causee par une phase complexe dans la matrice 3x3 CKM (Cabibbo-Kobayashi-Maskawa) de melange des quarks. L'experience LHCb compte utiliser les mesons B pour tester l'unitarite de cette matrice, en mesurant de diverses manieres independantes tous les angles et cotes du triangle d'unitarite. Cela permettra de surdeterminer le modele et, peut-etre, de mettre en evidence des incoherences qui seraient le signal de l'existence d'une physique au-dela du Modele Standard. La reconstruction du vertex de desintegration des particules est une condition fondamentale pour l'experience LHCb. La presence d'un vertex secondaire deplace est une signature de la desintegration de particules avec un quark b. Cette signature est utilisee dans le trigger topologique du LHCb. Le Vertex Locator (VeLo) doit fournir des mesures precises de coordonnees de passage des traces pres de la region d'interaction. Ces points sont ensuite utilises pour reconstruire les trajectoires des particules et l'identification des vertices secondaires et la mesure des temps de vie des hadrons avec quark b. L'electronique du VeLo est une partie essentielle du systeme d'acquisition de donnees et doit se conformer aux specifications de l'electronique de LHCb. La conception des circuits doit maximiser le rapport signal/bruit pour obtenir la meilleure performance de reconstruction des traces dans le detecteur. L'electronique, concue en parallele avec le developpement du detecteur de silicium, a parcouru plusieurs phases de decrites dans cette these. The LHCb experiment is being built at the future LHC accelerator at CERN. It is a forward single-arm spectrometer dedicated to precision measurements of CP violation and rare decays in the b quark sector. Presently it is finishing its R&D and final design stage. The construction already started for the magnet and calorimeters. In the Standard Model, CP violation arises via the complex phase of the 3 x 3 CKM (Cabibbo-Kobayashi-Maskawa) quark mixing matrix. The LHCb experiment will test the unitarity of this matrix by measuring in several theoretically unrelated ways all angles and sides of the so-called unitary triangle. This will allow to over-constrain the model and - hopefully - to exhibit inconsistencies which will be a signal of physics beyond the Standard Model. The Vertex reconstruction is a fundamental requirement for the LHCb experiment. Displaced secondary vertices are a distinctive feature of b-hadron decays. This signature is used in the LHCb topology trigger. The Vertex Locator (VeLo) has to provide precise measurements of track coordinates close to the interaction region. These are used to reconstruct production and decay vertices of beauty-hadrons and to provide accurate measurements of their decay lifetimes. The Vertex Locator electronics is an essential part of the data acquisition system and must conform to the overall LHCb electronics specification. The design of the electronics must maximise the signal to noise ratio in order to achieve the best tracking reconstruction performance in the detector. The electronics is being designed in parallel with the silicon detector development and went trough several prototyping phases, which are described in this thesis." @default.
- W63788104 created "2016-06-24" @default.
- W63788104 creator A5057034214 @default.
- W63788104 date "2003-01-01" @default.
- W63788104 modified "2023-09-27" @default.
- W63788104 title "Contribution to the Development of the LHCb Vertex Locator Readout Electronics" @default.
- W63788104 cites W1998636732 @default.
- W63788104 cites W2048398763 @default.
- W63788104 cites W2145351420 @default.
- W63788104 cites W2166784353 @default.
- W63788104 cites W2173188345 @default.
- W63788104 cites W2186823304 @default.
- W63788104 cites W2298770294 @default.
- W63788104 cites W2779402060 @default.
- W63788104 cites W2780817929 @default.
- W63788104 cites W2780975114 @default.
- W63788104 hasPublicationYear "2003" @default.
- W63788104 type Work @default.
- W63788104 sameAs 63788104 @default.
- W63788104 citedByCount "0" @default.
- W63788104 crossrefType "journal-article" @default.
- W63788104 hasAuthorship W63788104A5057034214 @default.
- W63788104 hasConcept C109214941 @default.
- W63788104 hasConcept C114614502 @default.
- W63788104 hasConcept C121332964 @default.
- W63788104 hasConcept C132525143 @default.
- W63788104 hasConcept C138885662 @default.
- W63788104 hasConcept C15708023 @default.
- W63788104 hasConcept C33923547 @default.
- W63788104 hasConcept C41002478 @default.
- W63788104 hasConcept C80899671 @default.
- W63788104 hasConceptScore W63788104C109214941 @default.
- W63788104 hasConceptScore W63788104C114614502 @default.
- W63788104 hasConceptScore W63788104C121332964 @default.
- W63788104 hasConceptScore W63788104C132525143 @default.
- W63788104 hasConceptScore W63788104C138885662 @default.
- W63788104 hasConceptScore W63788104C15708023 @default.
- W63788104 hasConceptScore W63788104C33923547 @default.
- W63788104 hasConceptScore W63788104C41002478 @default.
- W63788104 hasConceptScore W63788104C80899671 @default.
- W63788104 hasLocation W637881041 @default.
- W63788104 hasOpenAccess W63788104 @default.
- W63788104 hasPrimaryLocation W637881041 @default.
- W63788104 isParatext "false" @default.
- W63788104 isRetracted "false" @default.
- W63788104 magId "63788104" @default.
- W63788104 workType "article" @default.