- W75308376 abstract "The research and development program is described for a three-conductor compressed gas-insulated transmission line (CGIT). This includes the design and optimization of the sheath, conductors, posts and conical support insulators, and compressed gas insulation system. Calculations were made of the transient short circuit forces on the conductors and insulators. Two prototypes were made of a new design of 362 kV three-conductor system of buried rating 2000 A. The system was constructed by extruding the aluminum sheath in three segments, supporting the conductors on post insulators in each segment, and then welding the three segments together to form the completed CGIT section. The short circuit prototye passed 63 kA short circuit tests (0-G, 0-0, 20-G, 30) and there was good agreement between the measured and calculated forces. The high voltage prototype and trifurcation passed the high voltage design tests of 500 kV rms, 1050 kV BIL and 825 kV switching impulse. Tests were made of the system at full rated current (2000 A), and the temperature distribution on the conductor and sheath agreed with a new thermal analysis that was developed. A detailed cost breakdown and economic analysis is given of the three-conductor and isolated phase CGIT systems for voltage ratingmore » 145 kV through 800 kV, including the cost of installation and operation. The analysis indicates that the three-conductor CGIT systems have a lower effective installed cost (9 to 14%) than the isolated phase systems for buried installation, have lower losses of 12 to 36%, required a narrower trench and need only one third the number of field joints, resulting in a simpler, faster field installation.« less" @default.
- W75308376 created "2016-06-24" @default.
- W75308376 creator A5022322027 @default.
- W75308376 creator A5055274635 @default.
- W75308376 date "1979-02-01" @default.
- W75308376 modified "2023-09-25" @default.
- W75308376 title "Three-conductor compressed gas cable optimization. Final report" @default.
- W75308376 hasPublicationYear "1979" @default.
- W75308376 type Work @default.
- W75308376 sameAs 75308376 @default.
- W75308376 citedByCount "2" @default.
- W75308376 countsByYear W753083762014 @default.
- W75308376 countsByYear W753083762015 @default.
- W75308376 crossrefType "journal-article" @default.
- W75308376 hasAuthorship W75308376A5022322027 @default.
- W75308376 hasAuthorship W75308376A5055274635 @default.
- W75308376 hasConcept C119599485 @default.
- W75308376 hasConcept C127413603 @default.
- W75308376 hasConcept C159985019 @default.
- W75308376 hasConcept C165801399 @default.
- W75308376 hasConcept C192562407 @default.
- W75308376 hasConcept C202374169 @default.
- W75308376 hasConcept C212702 @default.
- W75308376 hasConcept C34800285 @default.
- W75308376 hasConcept C78519656 @default.
- W75308376 hasConcept C7943809 @default.
- W75308376 hasConcept C88182573 @default.
- W75308376 hasConceptScore W75308376C119599485 @default.
- W75308376 hasConceptScore W75308376C127413603 @default.
- W75308376 hasConceptScore W75308376C159985019 @default.
- W75308376 hasConceptScore W75308376C165801399 @default.
- W75308376 hasConceptScore W75308376C192562407 @default.
- W75308376 hasConceptScore W75308376C202374169 @default.
- W75308376 hasConceptScore W75308376C212702 @default.
- W75308376 hasConceptScore W75308376C34800285 @default.
- W75308376 hasConceptScore W75308376C78519656 @default.
- W75308376 hasConceptScore W75308376C7943809 @default.
- W75308376 hasConceptScore W75308376C88182573 @default.
- W75308376 hasLocation W753083761 @default.
- W75308376 hasOpenAccess W75308376 @default.
- W75308376 hasPrimaryLocation W753083761 @default.
- W75308376 isParatext "false" @default.
- W75308376 isRetracted "false" @default.
- W75308376 magId "75308376" @default.
- W75308376 workType "article" @default.